Outcomes of Transscleral Sulcus Fixation of Intraocular Lenses through a 2.4-mm Incision with an Injector System: 1-Year Follow-Up - PowerPoint PPT Presentation

About This Presentation
Title:

Outcomes of Transscleral Sulcus Fixation of Intraocular Lenses through a 2.4-mm Incision with an Injector System: 1-Year Follow-Up

Description:

... (9 patients) Lens subluxation : 1 eye Aphakia : 5 eyes IOL dislocation : 3 eyes the lenses were divided in the eye and extracted through 2.4mm incision. – PowerPoint PPT presentation

Number of Views:21
Avg rating:3.0/5.0
Slides: 10
Provided by: akiko
Category:

less

Transcript and Presenter's Notes

Title: Outcomes of Transscleral Sulcus Fixation of Intraocular Lenses through a 2.4-mm Incision with an Injector System: 1-Year Follow-Up


1
Outcomes of Transscleral Sulcus Fixation of
Intraocular Lenses through a 2.4-mm Incision with
an Injector System 1-Year Follow-Up
  • Akiko Masai, MD, Tomoichiro Ogawa, MD
  • Takuya Shiba, MD, Hiroshi Tsuneoka, MD
  • Department of Ophthalmology
  • The Jikei University School of Medicine
  • Tokyo, Japan
  • No financial interest

2
Objective
  • To evaluate postoperative outcomes of
    scleral-sutured ciliary sulcus fixation of
    foldable intraocular lens (IOL) through a 2.4-mm
    incision

3
Methods
  • Subjects 9 eyes (9 patients)
  • Lens subluxation 1 eye
  • Aphakia 5 eyes
  • IOL dislocation 3 eyes
  • ?the lenses were divided in the eye
  • and extracted through 2.4mm incision.
  • Variables examined
  • Best-corrected visual acuity (BCVA)
  • Before and after surgery (1 week 1, 3, 6, 12
    months)
  • Surgically induced astigmatism (SIA) (Cravy
    method)
  • After surgery (1 week 1, 3, 6, 12 months)
  • Endothelial cell density
  • Before and after surgery

4
Surgical Technique
  • Preparation for IOL setting of PC-9 hooking
  • 10-0 double polypropylene thread (PC-9, Alcon)
    inserted through cartridge (E1, HOYA)
  • PC-9 looped around haptics of IOL (VA70AD or
    VA65BB, HOYA) with cow-hitch knot

5
Surgical Technique
  • Scleral pockets created at the 2 and 8-oclock
    positions
  • Anterior vitrectomy performed
  • 2.4-mm scleral corneal incision created at
    12-oclock position
  • IOL setting IOL and hooked PC-9 loaded into
    cartridge
  • IOL inserted through incision with injector
    (ISH-001, HOYA), leaving opposite haptics out of
    the eye
  • PC-9 looped around haptics
  • IOL fixed to ciliary sulcus

6
Result 1
  • Early improvement in BCVA maintained for 1 year

BCVA (LogMAR)
7
Result 2
  • Surgically induced astigmatism was minimal

SIA (D)
8
Result 3
  • Mean endothelial cell density reduced 9.80

9
Conclusion
  • Sulcus fixation of an IOL by the injector
  • reduced the number of intraocular actions
    because of the preoperative preparation for IOL
    setting of PC-9 hooking.
  • allowed IOL insertion through a small incision.
  • With this technique, visual acuity improved early
    postoperatively and was maintained for 1 year
Write a Comment