Validation of WINDOW 6 and THERM 6 for Use in Determining the Solar Heat Gain Coefficients and UFact - PowerPoint PPT Presentation

1 / 13
About This Presentation
Title:

Validation of WINDOW 6 and THERM 6 for Use in Determining the Solar Heat Gain Coefficients and UFact

Description:

2 Woven Blinds (Loose & Dense Weave, Tight & Loose Fit) 4 Venetian Blinds (Open, 45 ... 1 Retracted (Venetian Blind) 2 Outside Shading System Tests. 2 ... – PowerPoint PPT presentation

Number of Views:55
Avg rating:3.0/5.0
Slides: 14
Provided by: william217
Category:

less

Transcript and Presenter's Notes

Title: Validation of WINDOW 6 and THERM 6 for Use in Determining the Solar Heat Gain Coefficients and UFact


1
Validation of WINDOW 6 and THERM 6 for Use in
Determining the Solar Heat Gain Coefficients and
U-Factors of Complex Glazing Systems Research
Project
  • William C. duPont/Sunergy Consulting
  • Ross McCluney/Sun Pine Consulting
  • NFRC Project Number 07-101-RP

2
Background
  • WINDOW 6 and THERM 6 are currently under
    development with new capabilities
  • Calculate the SHGC and U-Factor of
  • Woven Shades,
  • Venetian Blinds, and
  • Fritted Glass
  • Shading Systems Can Be Located
  • Inside
  • Between Glazing
  • Outside

3
Project Objectives
  • Perform and coordinate the data collection,
    research, and testing to validate the new
    features within WINDOW 6 and THERM 6

4
Project Tasks
  • Task 1 Literature Search
  • Compile and Evaluate Existing SHGC and U-Factor
    Test Results
  • Describe Existing Methods of Calculating SHGC and
    U-Factors
  • Task 2 Perform Tests and Simulations
  • Identify and Procure Test Specimens
  • Perform SHGC and U-Factor Tests
  • Perform SHGC and U-Factor Simulations
  • Task 3 Compare and Evaluate Results
  • Literature Search
  • SHGC and U-Factor Test Results
  • Task 4 Status Reports and Peer-Reviewed Paper

5
Project Deliverables
  • Task 1 Literature Search (3 Months)
  • Compile and Evaluate Existing SHGC and U-Factor
    Test Results
  • Describe Existing Methods of Calculating SHGC and
    U-Factors
  • Task 2 Perform Tests and Simulations (7 Months)
  • Identify and Procure Test Specimens
  • Perform SHGC and U-Factor Tests
  • Perform SHGC and U-Factor Simulations
  • Task 3 Compare and Evaluate Results (2 Months)
  • Literature Search
  • SHGC and U-Factor Test Results
  • Task 4 Status Reports and Peer-Reviewed Papers
    (3 Months)

6
Task 1 Overview
  • Existing SHGC and U-Factor Test Results
  • Approached manufacturers and researchers who have
    products tested to submit similar or identical
    specimens (and previous results).
  • ASHRAE Papers and Reports
  • Queens University
  • Tait Solar
  • University of Waterloo
  • NFRC Research Projects
  • Black Blind Tilted
  • Glass Block
  • 7 Glazings with 9 Shades
  • European Research Projects
  • Lund University

7
Task 1 Overview(Continued)
  • Existing SHGC and U-Factor Calculation
    Methodologies
  • ASHRAE Methods
  • ASHRAE 1311-RP
  • Existing SHGC Load Calculation Method
  • European Methods
  • EN 14500 EN 14501

8
Task 2a Overview
  • Selection of Test Specimens
  • 26 SHGC Tests
  • 20 U-Factor Tests
  • Initial Test Specimen List (Contract)
  • 6 Simple Glazing System Tests
  • 4 Reference Glazing
  • 2 Fritted Glazing Samples (High Low Density)
  • 5 Inside Shading System Tests
  • 2 Woven Blinds (Loose Dense Weave, Tight
    Loose Fit)
  • 1 Venetian Blinds (Open, 45?, Closed)
  • 14 Between-Glazing Shading System Tests
  • 2 Woven Blinds (Loose Dense Weave, Tight
    Loose Fit)
  • 4 Venetian Blinds (Open, 45?, Closed, Thin
    Thick Pane Spacing)
  • 2 Retracted (Venetian Blind Woven Blind)
  • 1 Outside Shading System Tests
  • 1 Sunscreen

9
Task 2a Overview(Continued)
  • Revision of Test Specimen List
  • In Collaboration with the PMTG
  • Revised Test Specimen List
  • 6 Simple Glazing System Tests
  • 4 Reference Glazing
  • 2 Fritted Glazing Samples (High Low Density)
  • 8 Inside Shading System Tests
  • 4 Woven Blinds (Loose Dense Weave, Tight
    Loose Fit)
  • 2 Venetian Blinds (Open, 45?, Closed, High Low
    Absorptance)
  • 10 Between-Glazing Shading System Tests
  • 2 Woven Blinds
  • 3 Venetian Blinds (Open, 45?, Closed, Thin
    Thick Pane Spacing)
  • 1 Retracted (Venetian Blind)
  • 2 Outside Shading System Tests
  • 2 Sunscreen (Loose and Dense Weave)

10
Task 2b Overview
  • Perform SHGC Tests
  • NFRC 201 Accredited Testing Laboratory
  • Installation of Fenestration Attachments
  • Sometimes Difficult to Install Properly at Tilt
  • Verified by Sunergy Consulting
  • Instrumentation of Test Specimens
  • Added Temperature Sensors
  • Monitor Atmospheric Data to Adjust Solar Spectrum
  • Reporting Requirements
  • Calibration Reports and Reference Glazing Tests
  • Raw Data in Electronic Format
  • Proposal and Addendum Received from ATI

11
Task 2b Overview(Continued)
  • Perform U-Factor Tests
  • NFRC 102 Accredited Testing Laboratory
  • Installation of Fenestration Attachments
  • Verified by Sunergy Consulting
  • Instrumentation of Test Specimens
  • Add Temperature Sensors (ASTM C 1199 ASTM E
    1423)
  • Reporting Requirements
  • ASTM C 1363 and CTS Calibration Reports
  • Raw Data in Electronic Format
  • RFP Distributed in May 2008
  • Response from 3 Laboratories (One Company)
  • ATI Fresno (All Specimens)
  • ATI Minnesota (2 Specimens)
  • ATI York (2 Specimens)

12
Task 2c Overview
  • Perform SHGC and U-Factor Calculations
  • NFRC Accredited Simulation Laboratory
  • NFRC 100 and NFRC 200 Procedures
  • WINDOW 6 and THERM 6
  • Simulated as Tested
  • As Installed in Solar Calorimeter or Thermal
    Chamber
  • At Environmental Conditions Experienced During
    Testing
  • Reporting Requirements
  • Written Reports and All Electronic Files
  • Critique Simulation Methodologies and
    Documentation
  • RFP Ready for Distribution

13
Current Issues
  • Finalize and Prioritize Test Specimen List
  • Replacements Based on Initial Test Results
  • Seek Donation of Test Specimens!
  • Start SHGC Testing
Write a Comment