Extended Coupling Correction and Emittance Diagnostic Section for - PowerPoint PPT Presentation

1 / 13
About This Presentation
Title:

Extended Coupling Correction and Emittance Diagnostic Section for

Description:

(3) use 0.8 m bends (as used in ATF) instead of 1 m for better field stability and more space ... one attempt at full 4D beam matrix measurement and ... – PowerPoint PPT presentation

Number of Views:27
Avg rating:3.0/5.0
Slides: 14
Provided by: MARKWO3
Category:

less

Transcript and Presenter's Notes

Title: Extended Coupling Correction and Emittance Diagnostic Section for


1
Extended Coupling Correction and Emittance
Diagnostic Section for optimal ATF2
Coupling Correction / Emittance Diagnostics
FONT
nBPM (SLAC)
nBPM (KEK)
Compton / laserwire
Existing ATF Extraction Line
ODR
2
(No Transcript)
3
FF Optics Modifications
  • From Tauchi-sans email (bds 117 June 2, 2005)
  • 5. Optics modifications
  • (1) concentrate on "optimal" design (straight)
    done
  • (2) change bends from sector bends to
    rectangular done
  • (3) use 0.8 m bends (as used in ATF) instead of
    1 m for better field stability and more space
    done
  • (4) remove octupoles (do not use them, and they
    are tight) done (OC0 removed OC1 moved away
    from SF1)
  • (5) extend diagnostics section (use up to 10 m
    additional space) done
  • (6) QM14 is the strongest quad, and is close to
    max field of BT quads, need to check if its
    strength can be reduced by reoptimizing the
    matching section done (QM14K1L -1.1 m-1)

4
ßx,y 4,0.1 mm
?L 7.1 m (w.r.t. baseline)
30 cm offset
5
Assembly Hall
optimal
baseline
6
-1
1
7
Coupling Correction
  • ideally
  • correction section with 4 independent skew
    quadrupoles, followed by
  • 2D (4 wire scanner) emittance measurement section
  • optics for orthogonal control of the 4 coupling
    phases
  • minimize ey once with each skew quadrupole
  • in present ATF extraction line
  • non-optimal optics in EXT straight section
  • wire scanners and skew quads interspersed
  • each wire scanner has x, y, and u/v (small
    angle, 10) wires
  • one attempt at full 4D beam matrix measurement
    and correction was inconclusive1

1 See http//atfweb.kek.jp/atf/Reports/ATF-99-01.p
df
8
Ideal skew correction / e diagnostic section
SQ
SQ
SQ
SQ
WS
WS
WS
WS
x y
90 90
180 90
90 90
45 45
45 45
45 45
See http//www.slac.stanford.edu/cgi-wrap/getdoc/
slac-pub-8581.pdf
9
SQ
SQ
SQ
SQ
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
1.3
1.3
1.3
1.3
WS
WS
WS
WS
WS
x y
90 90
180 90
90 90
33 57
57 33
33 57
57 33
59.2 10.8
108.0 5.9
59.2 10.8
108.0 5.9
59.2 10.8
s (µm)
For MAD files see http//www.slac.stanford.edu/m
dw/ATF2/optimal
10
new quadrupole (between QF3X and BH1X.3)
11
A Drift e-Diagnostic Section
from Paul Emma
b
s
L
w1
w2
w3
3 wire scanners (or profile monitors)
12
x y
smin 3 µm
13
Continuing Work
  • optimize system bandwidth and performance
  • add BPMs and dipole correctors
  • simulate steering and dispersion/coupling
    correction with machine/diagnostic errors
  • verify what space is needed for diagnostic
    equipment in chicane
  • investigate drift ediagnostic section
  • writeup for ATF2 proposal document
Write a Comment
User Comments (0)
About PowerShow.com