Presentazione di PowerPoint - PowerPoint PPT Presentation

1 / 46
About This Presentation
Title:

Presentazione di PowerPoint

Description:

The output of the motor potentiometer can be add to a Speed Reference or used as ... When the Motor potentiometer is used as multiplier ... MOTOR POTENTIOMETER ... – PowerPoint PPT presentation

Number of Views:63
Avg rating:3.0/5.0
Slides: 47
Provided by: martinel
Category:

less

Transcript and Presenter's Notes

Title: Presentazione di PowerPoint


1
XVy-EVolution
2
XVy-EVolution
Continuous current from 3Arms to 580Arms
3
XVy_EV naming system
XVy_EV 5100180 - KBX - PDP
By the way to have a clear identification, the
new name depends on the Rated and Overload
current of the drive
4
XVy-EV
  • NEW Regulation board
  • The new board wont change any interface with the
    actual one (terminals, jumpers, etc)
  • The card is replaceable with the old one (the
    power section remains the same)
  •  

5
XVy-EV
  • Regulation board improvement
  • The microcontroller C167 with 25MHz is replaced
    with the more performing processors C167CR-L33M
    working at 32 MHz.
  • This allows
  • Improvement of the power calculation and the
    management of more performing and complex
    applications
  • CanOpen baud rate at 1 Mbit
  • Improvement of the SoftScope use
  •  

6
XVy-EV
NEW SW version
  • Asyncronous Version
  • XVyABasic V4_22.sre
  • XVyABasic V4_22.sre
  • Brushless Version
  • XVyBasic V4_22.sre
  • XVyBasic V4_22.sre

7
XVy-EV
  • New Keypad
  • The keypad is the same of the actual AVy,
  • where are also available more navigation
  • Buttons
  • Start / Stop
  • Disable
  • Jog and Jog
  • Motorpot and -
  • The name is KBXV-EV

8
  New FW functions
  •  Alphanumeric Keypad
  • In order to make more user-friendly
  • the drive interface, the parameters
  • description is in alphanumeric mode.
  • The parameters description is in
  • a single language (short technical terms in
    English).
  • File Parameter Storage
  • The keypad is able to upload and download one
    file parameter of the drive.

9
Hardware Update
  • Improvements of the connection of the absolute
    encoders EnDat to the expansion card
    EXP-ABS-XVy.
  • It is no longer necessary to double the encoder
    cable.
  • The full data encoder have to be connected to the
    XE1 connector on the ABS card.
  • The new card has a second XE2 connector used to
    repeat the incremental tracks to the standard XE
    connector on the regulation board

10
Hardware Update
  • Add a new connectors for a fast disconnection /
    connection of the braking resistor
  • Easy disconnection and removal of the cable to
    the BR1 and C terminal

11
Hardware Update
  • Digital I/O with NPN and PNP configuration
    selection
  • PNP configuration

12
Hardware Update
  • Digital I/O with NPN and PNP configuration
    selection
  • NPN configuration

13
Hardware Update
  •  
  • Fast inputs
  • Digital inputs 6 and 7 are wired as Hardware
    Interrupt. They could be used to store the
    encoders position.
  • Input 5 could be used as integrated function
    Counter. It is able to count squared waveform
    max 8khz. (positive slope, negative slope,
    positive and negative slope).
  • These functions are available only in MDPLC
    application.
  •  

14
Hardware Update
  •  Fast Link network
  • Increased the max number of Slave from 7 to 15
    (16 taking part in the net)

15
Fast Link encoder repetition can be used
together.
Hardware Update
16
  • NOTE
  • The new FW runs only with the new regulator
    board at 32 MHz.
  • It is not possible to perform a network through
    fast-link with drive having both 25MHz and NEW
    32MHz processors.

17
Hardware Up-to-dating
  • Encoder inputs
  • Pull-up / down resistors added to the optional
    ENC-ADPT card
  • Which configuration (NPN PNP)?

18
XVy-EV SIZES
19
  New FW functions
  • The XVy_EV perform two different overload
    algorithms
  • IxT control
  • dedicated to high dynamic application where the
    overload can reach the 200 of the drive rated
    current
  • I2T control
  • suitable in applications where it is requested a
    lower overload for a longer time (136 In Class1
    for 60s every 300s)
  • Typical applications are the continuous lines. 

20
  I2T control
  • Example
  • For the same machine where is requested a
    standard overload 150 every 60s we to choice
    between an asynchronous solution or a brushless
    solution with the following data

Brushless SBM78 30 3 Nominal Torque
21Nm Nominal Speed 3000rpm Nominal Current
13.3A Nominal Power 6.6KW
Asynchronous AX 100K.2 Nominal Torque
21Nm Nominal Speed 3000rpm Nominal Current
15.4A Nominal Power 6.6KW
21
  I2T control
  • Example
  • Using the current XVy drive we have to select the
    following size

Asynchronous Current request at Start 15.4
150 23.1A Drive size XVyA-2075-KBX
Brushless Current request at Start 13.3 150
19.9A Drive size XVy-32040-KBX
The XVy-32040 have the same power section as the
asynchronous version with the size 11KW, so we
have to use a brushless drive 1 size greater.
22
  Overload control
  • Example

Test of the overload using the current XVy 21530
(with IT overload control) In 15A Iovld 30
for Tovld 1s Motor overload Imot 19.9A
Tovld 19.9 (Iovld In)Tovld / (Imot
In) Tovld 19.9 (30 15)1 / (19.9 15)
3.06s It is not enough for the above mentioned
application
23
  IxT Control
24
  I2T control
  • Example

Test of the overload using the new XVy_EV
21530 In 17.7A Isl-ov 24.1 for Tsl-ov
60s Motor overload Imot 19.9A
Tsl-ov19.9 (Isl-ov2 In2)Tsl-ov / (Imot2
In2) Tsl-ov19.9 (24.12 17.72)60 / (19.92
17.72) 194s It is right for the above
mentioned application
25
  I2T Control
26
  New FW functions
  • Password
  • It has been implemented a Password with two entry
    level
  • User to avoid modifications in the file
    parameter of the drive by not authorized people
  • The customer can set his personal value.
  • Service reserved to SIEI personnel only
  • Both the password value has to be set in the same
    parameter
  • Keypad PSWD
  • The User password has effect only by using the
    keypad. If used, it allows to read only the
    MONITOR parameter.
  • Using the E_at_syDrive configuration software it is
    anyway possible to read all the parameter (apart
    the Service menu)

27
  New FW functions
  • Implementation of the management of encoders with
    EnDat 2.2 protocol
  • Added HYPERFACE protocol on EXP-ABS-XVy optional
    card
  • Increase of the number of words
  • The number of words exchangeable through filedbus
    (DeviceNET, CANOpen ProfibusDP) will be increased
    from 8 to 12

28
  New FW functions
  • Coast-through function
  • The coast-through function will be improved
    adding the emergency-stop function (same as AVy
    version 1.9 FW).

29
  New FW functions
  • HELPER
  • Integrated into the Basic Firmware the ability to
    send a torque output signal to a slave through
    Fast-link. Refresh time 250micros

30
  New FW functions
  • SPEED DRAW
  • This function allows to multiply the Speed
    reference times a Speed Draw Ratio settable by
    Analog Input or Bus (same as AVy version 1.9 FW).
  • The multiplier will be bypassed in case of Jog or
  • Configuration Mode ? Speed

31
 
MOTOR POTENTIOMETER
  • This function allows to set a Speed reference by
    Keypad, Digital Input, Serial line or Bus.
  • The output of the motor potentiometer can be add
    to a Speed Reference or used as a multiplier of
    the Speed reference (through the Speed Draw
    function).

32
 
MOTOR POTENTIOMETER
  • When the Motor potentiometer is used as
    multiplier of the Speed Reference, it is possible
    to set the Min. and Max. multiplier factor.
  • Doing that the operator can define for example
    to multiply the main reference within a defined
    ratio e.g. /- 15.
  • If the Motor pot is used in addition to the main
    reference, the standard Ramp of the drive will be
    overwrite by the Motor pot acceleration and
    deceleration time.
  • If the Motor pot is used to multiply the main
    reference, the standard Ramp of the drive is
    fully independent from the Motor pot acceleration
    and deceleration time.
  • If a Motor Pot command is assigned to a Digital
    Input, this have priority compared to any setting
    via Keypad, Serial line or Bus

33
  New FW functions
  POSITIONING CONTROL
  • Positioning control without Homing needed
  • Position Reference via Analog Input.
  • The Position Mode parameter must to be set in
    Absolute
  • 10V on the Analog Reference correspond to Max
    Pres Abs Val
  • The Position reference is showed in the
    parameter Pos preset 0
  • There are two way to use this function
  • Pos An Mode Step
  • Pos An Mode Continuous

34
 ANALOG POSITION REFERENCE
  • Pos An Mode Step
  • When the motor reaches the Position reference
    (Pos Reached On), any other modification in the
    reference will be ignored.
  • To start for a new set point it is necessary to
    give one more Pos Start Pos command.
  • If the Position reference is continuously
    modified during the movement of the motor, it is
    continuously refreshed.
  • If, during the movement of the motor, the
    Position reference became stable, any other
    modification will be ignored.

35
 ANALOG POSITION REFERENCE
  • Pos An Mode Continuous
  • The position reference is continuously
    refreshed.
  • Any modification in the Position reference will
    be followed by the motor without any transition
    in the Pos Start Pos command.
  • It is strongly recommended to well set the
    parameter
  • Pos An Wind Del
  • Pos An Stdy Wind
  • Pos An Filter 0 (default value 0.2)

36
  New FW functions
  POSITIONING CONTROL
  • Multi Positioning Control (sequence of events)
  • It is possible to define a sequence of position
    defined in Pos Preset 0 and Pos Preset 7.
  • When a position is reached it is possible to go
    on with the next position if is verified a
    defined condition.
  • Possible condition are
  • Delay after Pos Reached
  • Event from Digital Input or Bus
  • Delay Event

37
  POSITIONING CONTROL
Multi Positioning Control
  • Depending on the application, it is possible to
    configure the parameter Position Mode in
    Absolute or in Incremental mode.
  • Making a loop between the Pos Preset X it is
    possible to work continuously like for a Belt
    Conveyor

38
 E_at_SYDRIVE tool
  • The tool recognize directly the Drive Size and
    Software Version
  • It is possible to work ONLINE or OFFLINE

39
E_at_SYDRIVE tool
 
  • It is possible to select the new Software Version
    (4.22) or the old ones (without HTML pages)

40
E_at_SYDRIVE tool
 
  • It is possible to edit the XVy parameter list or
    to use the Wizard

41
E_at_SYDRIVE tool
 
  • It is possible to select the motor and than
    automatically set the parameter into the drive
    using the Motors Database

42
E_at_SYDRIVE tool
 
  • It is possible to define a new Motors Database

43
E_at_SYDRIVE tool
 
  • After the Import Data command the new Motor well
    be imported in the Data Base

44
E_at_SYDRIVE tool
 
  • New SoftScope2 Version 1.0
  • it is possible to open the scope tool directly
    from E_at_syDrive icons
  • Service -gt Tools -gt Softcope

45
New HTML pages for Custom application
  • It is on development by the Application Office a
    normalization of some of the last application
    realized in particular Flying Shear and Feeders
    control.
  • These application will be downloadable in the
    regulation card and manageable through the PC
    configuration software E_at_sy Drive by using some
    dedicated HTML pages.
  • The pages will be specifically related to the
    application itself and then from here all the
    data could be changed and monitored.

46
XVy-EV
Password for special applications
  • FOR SPECIAL SIEI APPLICATIONS IT IS NECESSARY
  • A DEDICATED PASSWORD
  • IN THIS CASE THE CUSTOMER WILL RECEIVE A PLC KEY
    THAT WORKS WITH JUST THE APPLICATION HE ASKED
    FOR.
Write a Comment
User Comments (0)
About PowerShow.com