Title: MaxSG Low Voltage Switchgear
1- MaxSG Low Voltage Switchgear
- Automation Technology Division
- Wichita Falls, Texas
- 940-397-7000
2Value Proposition
- Our value proposition that we create for the
customer is that we - offer
- Best of breed
- World-class, topnotch circuit breakers,
switchgear, systems - Engineered with highest safety, reliability and
ease of operation - We are highly customer-focused
- Quick response to customer concerns
- Topnotch engineering support
- Accommodate customer change requests
- Pre-sale design advice
- Highest customer friendly service and support
3LV Power Distribution
- Max LINE A full line of low voltage power
distribution equipment
4Standards
SWITCHGEAR ANSI C37.20.1 -Metal Enclosed LV
Power Circuit Breaker Switchgear ANSI C37.51
-Testing of Metal Enclosed LV AC Power
Circuit Breaker Switchgear UL 1558 -Switchgear
Assemblies CIRCUIT BREAKER ANSI C37.13 LV
AC Power Circuit Breakers Used in Equipment
ANSI C37.16 Preferred Rating, Related
Requirement, Application Recommendations
For LV Power Circuit Breakers and AC Power
Circuit Protectors ANSI C37.50 Testing of
Low Voltage AC Power Circuit Breakers UL 1066
Low Voltage Power Circuit Breakers
5BREAKERS
6Breakers of Choice
- Power (Air) Circuit Breaker
7Air (Power) Circuit Breakers
- High Interrupting Capability
- Extremely High Mechanical Electrical life
- Manual / Electric Operation
8Air (Power) Circuit Breakers - Emax
- Five Frame Sizes
- E1 800 - 1200 Amps
- E2 800 1600 Amps
- E3 800 - 2500 Amps
- E4 3200 3600 Amps
- E6 4000 - 5000 Amps
9Air (Power) Circuit Breakers
- Emax - Three Trip Unit Versions
- PR121
- Protection Features Only
- PR122
- Protection Features
- LCD Display
- Current Measurement
- Contact Wear
- Communications option
- PR123
- PR122 Features
- Harmonic Measurements
- Communications option
10Air (Power) Circuit Breakers
- Common set of accessories for all breaker frames.
- Control isolated from power poles.
- Install or change accessories and maintain UL
listing. - Pre-wired for quick connection.
11SWITCHGEAR
12LV Switchgear MaxSG
13LV Switchgear MaxSG - Specification
- UL 1558 approved
- ANSI C37.20.1, C37.51
- lt600 VAC
- 50/60Hz
- 800-5000 Amps Bus
- 42 kA to 125 kA Symmetrical Short Circuit Rating
- Main-Tie-Main Transfer Schemes
- Indoor Nema 1
- Outdoor N3R Non Walk-in Walk-in
- Seismic Zone 4 Certified
- CSA Approved
- Mimic bus
- Communication
14LV Switchgear MaxSG - Specification Cont.
- Complete closed door breaker operation
- Silver (Tin) plated bus
- Kirk Keys
- Transformer or bus duct connections
- Overhead lifting device
- Breaker lift truck
15LAYOUT
16LV Switchgear MaxSG
17LV Switchgear MaxSG - Layout
21 and 42 instrument compartment
Install main or ties in C compartment and one
feeder breaker in D.
18LV Switchgear MaxSG - Dimensions
E4 3600 Amp E3 2000 Amp E6 5000 Amp
E4 3200 Amp E2 1600 Amp E6 4000 Amp
E3 2500 Amp E2 800, 1200 Amp 1000 mm, 40
800 mm, 32 600 mm, 24
19LV Switchgear MaxSG
- Standard Depth
- 1650 mm / 65
- Optional 1900mm / 75
- Standard Height
- 2290 mm / 90
20NEMA 3R Outdoor
- Non Walk-in
- Walk-in, with 36 isle in front of breaker
- Space heaters and thermostat
- Doors with latching mechanism to prevent
inadvertent closing - Fluorescent Lights Receptacles
- Optional undercoating
21CONSTRUCTION
22Construction
- Structure
- 12 ga steel rigid self supporting, expandable
C-channel frame - Doors
- Front doors - Semi-concealed hinges
- Rear doors Bolted, optional hinge, Pad-locking
handles available - Bus Sized per ANSI/UL requirements,
- Silver plated copper,
- Full length ground bus,
- 50 / 100 neutral available.
23Structure
Door Semi-concealed hinges from
tampering Standard bolted rear
cover Optional hinged rear door
Rear cable area
Paint electro static powder coat ANSI gray 61
24Bus Design
- All bus rated for ANSI and UL
- Standard temperature rise
- Max 65ºC over 40ºC ambient
- Bare bus is standard
- Insulated bus system is optional
- Adhesive coated tapes on connection joints
- Flexible boots are optional
- Bus bracing using steel supported
- polyester type fingerplates
25Features
- Silver plated bus - standard
- Tin plated optional
- Steel barriers provided as
- option for rear cable isolation
26Customer Connections
- Control wire terminated at breaker cell
- Reduces number of terminations
- Ample routing and termination areas
- Inter-cubical wiring made easy
- Terminal strips
- Located in wire way on top of enclosure
- Customer power connections made easy
- NEMA 2 hole pattern set at 45 angle for top and
bottom entry - 1650mm / 65in standard depth (1900mm / 75in
optional) provides large cable area.
27User Safety
- Safety shutters are standard
- Pad locking accessories
- Lock breaker in open position
- Lock breaker in test disconnect position
- Lock shutters in closed position
- Breakers and cells keyed
- Insulated bus available
- Barriers
- Main Bus
- Compartment
Anti-insertion key
28Instrument Compartment
Pilot lamps on breaker door
Mimic Bus
Control switch
29Control Wiring
Control circuit isolation Customer terminal
block connection
CT Mounting on Bus
Can offer customer Specified paint color
Front door grounding
30Breaker Compartment
31Breaker Draw Out Version
- CAPTION
- Trademark, size of CB
- Trip unit
- PB for manual opening
- PB for manual closing
- Lever to manually charge
- closing spring
- Label with electrical
- characteristics
- Mechanical device to signal
- CB open O and Closed I
- Signal for springs charged
- or discharged
- Mechanical indication of trip
- Key lock in open position
- Key lock and padlock in
- racking-in, racking-out position
- 12. Racking-in, racking-out device
- Terminal box
32Position Switch Contacts
- No T.O.C. contacts standard
- Optional 5 Truck Operated Contacts
- (2) Racked in, (2) Racked-out, (1) Test Position
- Optional 10 Truck Operated Contacts
- (4) Racked in, (4) Racked-out, (2) Test Position
33Auxiliary Switch Contacts
- 4 Auxiliary contacts standard
- (2) N.O. and (2) N.C. , Plus (2) extra are
dedicated to the trip unit - Optional 10 Auxiliary contacts
- (5) N.O. and (5) N.C. , Plus (2) extra are
dedicated to the trip unit (PR122/PR123 only) - Optional 15 Auxiliary contacts
- Contacts are configurable and located outside the
breaker
34BREAKER COMPARTMENT
PADLOCK DOOR (STANDARD)
PADLOCK DOOR LATCHABLE(OPTIONAL)
PADLOCK DEVICE FOR SAFETY SHUTTER
MECHANICAL LOCK FOR COMPARTMENT DOOR (OPTIONAL)
35MECHANICAL INTERLOCKS
36MECHANICAL INTERLOCKS - Optional
Vertical Interlock
Horizontal Interlock
37MECHANICAL INTERLOCK OF BREAKERS
38INSTRUMENTATION
39LV Switchgear MaxSG
- Breaker door mounted lights, meters and control
- Indicating lights
- Miniature volt and amp meter
- Miniature breaker control switch
- Digital Multifunction Meters
- Power Measurement Meters
- GE PQM
- GE Multilin Family
- Square D Circuit Monitors
- Allen Bradley Meters
- Electro Industries Meters
- Shark 100
- ABB Color Touchscreen
- CX Series
40LV Switchgear MaxSG - Metering
- Customer metering for mid and advanced
applications - Mid
- Volts, Amps, Power, Energy, THD
- Communications RS-485 Modbus
- Advanced
- Volts, Amps, Power Energy
- Harmonics
- Communications
- Ethernet or Profibus
- DCS
- RS-485 Modbus
- I/O
- Revenue Class
41Custom Metering/Communication
- Provide GE PQM Power Quality Meter and Multilin
product line for main-tie-main protection and/or
generator protection. - Provide Power Measurement ION 6200, 7300, 7350,
7550, 7650,7700 and 8600 Energy Power Quality
Meter with metering modbus configuration setup,
and ABB Emax breakers all connected in modbus
configuration. - Supply Power Logic series Circuit Monitors in
modbus communication to customer for monitoring
each breaker status. - Provide central display unit (CX series touch
screens) to provide all the breakers trip unit
data when they are all connected in modbus
communication. - ABB TVSS Surge suppressors or customer specified
TVSS. - SD-Pocket is an application designed to connect
Emax trip units to a PDA or personal computer. - SD-View 2000 and TestBus2.
42COMMUNICATION DEVICES
43LV Switchgear MaxSG
- Breaker Communications
- Available as option with PR122, and PR123 trip
units - Communicates
- Metered values
- Breaker status
- Protection Parameters
- Number of Operations
- Last Event
- Contact Ware
- Pre Alarms
- Modbus protocol
- Optional Bluetooth
44Communication Systems SD-View 2000
PC based software system
45Communication Systems SD-View 2000
- SD-View 2000, PC-based software system enables
communication - Send opening/closing commands to circuit-breakers
- Read electrical installation values (current,
voltage, power factor, etc.) - Read and modify trip characteristics of
protection units - Log of history of installation
- Status of apparatus
- Abnormal operating situation
- Current, voltage, power measurements in real time
46Communication Devices - SD Pocket
- SD-Pocket is an application designed to
- connect new protection releases to a PDA
- or PC
- Enables use of wireless communication to
- Configure protection threshold function
- Monitor measurement functions
- Verify status of the circuit-breaker
- SD-Pocket application scenarios include
- During start-up of switchgear, with rapid and
error-free transfer of the - protection parameters to the releases (also using
the dedicated exchange file directly - from Docwin)
- During normal installation service, gathering
information on the circuit-breaker - and load conditions (last trip information,
runtime currents, and other information)
47Test Bus2
- Diagnostic software for RS485 bus at startup
service - Troubleshoot entire modbus network for their
settings and addresses
48Touch Screen CX Series
49Touch Screens Man Machine Interface Products
- CX553 (5.7 Color TFT)
- CX553-1 (5.7" Color TFT)
- CX554-HB (5.7" Color High Contrast)
- CX554-3 (7.7" Color TFT)
- CX555 (10.4" Color TFT)
- Windows CE screen available
- CX554-3 above have printer ports
Touch pads, Touch Monitors Industrial PCs
available
- Extended Modbus master
- Control up to 256 devices
- Printer Ports Ethernet
- Available on certain models
50(No Transcript)