Chevron - PowerPoint PPT Presentation

1 / 26
About This Presentation
Title:

Chevron

Description:

Chevron s Power Performance Monitoring Solution Presented by: Ken Yoss Roy Blanco * * YOSS: Upstream and downstream power facilities are STAFFED AS POWER IS NOT AN ... – PowerPoint PPT presentation

Number of Views:241
Avg rating:3.0/5.0
Slides: 27
Provided by: RoyBl4
Category:

less

Transcript and Presenter's Notes

Title: Chevron


1
Chevrons Power Performance Monitoring
Solution Presented by Ken Yoss Roy Blanco
2
Agenda
  • Power Support Center Overview
  • PSC Performance Monitoring Solution
  • PSC Workflow Process
  • El Segundo Refinery CHP Overview
  • Case Studies
  • QA

3
Power Support Center Capabilities
Monitoring Diagnostics Center
  • Power Solutions Network
  • Business planning support
  • Operations philosophy and tools
  • Maintenance philosophy and tools
  • Engineering and technical solutions
  • Performance monitoring/trip analysis
  • Training/OC development
  • Equipment modifications and upgrades

4
Power Support Center Organization
Central PSC Office
Turbine Parts QA/QC Management Turbine
Metallurgist Expertise
Equipment Assessment Upgrades
Major Inspection Management
OM Philosophy Tools OE Compatible
Refineries
Performance Monitoring Diagnostics
Engineering Analysis
Oil Gas Operations
PI Administration
Project Management
KPI Tracking
Business Plan Development
5
PSC Performance Monitoring Solution
  • OSIsoft EA for data infrastructure
  • ProcessBook
  • Datalink
  • To come
  • MD
  • RT Webparts via SharePoint
  • AF2.0 Notifications
  • Etc.
  • SmartSignal for predictive analytics
  • SmartSignal EPICenter
  • SmartSignal participates in the performance
    monitoring portion of the weekly PSC/ES
    teleconference.
  • To come
  • Transition to Chevron hosted, monitored and
    maintained instance of EPICenter.

6
El Segundo Refinery CHP Overview
  • Located on the Pacific coast in El Segundo, CA
    just south of LAX.
  • 3 - Cogeneration Trains (GE Frame 6Bs, dual
    pressure HRSGs), 170,000 hrs.
  • 1 - Steam Turbine Generator
  • 1 - Auxiliary Boiler
  • 2 - Sets of BFWPs

7
Case Study High Steam Drum Conductivity
8
Case Study High Steam Drum Conductivity
9
Case Study High Steam Drum Conductivity
10
Case Study High Steam Drum Conductivity
11
Case Study High Steam Drum Conductivity
12
Case Study High Steam Drum Conductivity
  • Value delivered
  • Long term reliability
  • Confirmation of equipment issues

13
PSC Performance Monitoring Workflow
PSC Ops Engineer
PSC Ops Engineer
14
Case Study NH3 Over Injection
11/7/2008 PSC received phone call from
SmartSignal APC informing of a NH3/air ratio High
Rule posting on the WatchList.
15
Case Study NH3 Over Injection
16
Case Study NH3 Over Injection
16
Note Identified in SmartSignal Trended in PI
for visual aid.
17
Case Study NH3 Over Injection
  • Value delivered
  • Decrease in NH3 release to atmosphere
  • decrease in NH3 purchases
  • Operational procedures/training modified

17
Note Identified in SmartSignal Trended in PI
for visual aid.
18
PSC Performance Monitoring Workflow
PSC Ops Engineer
PSC Ops Engineer
19
Case Study NH3 Control Valve
20
Case Study NH3 Control Valve
21
Case Study NH3 Control Valve
22
Case Study NH3 Control Valve
23
Case Study NH3 Control Valve
  • Path forward
  • Find optimal NOx ppm setpoint for SCR
  • efficiency and operability
  • Upgrade the SCR system

24
PSC Performance Monitoring Workflow
PSC Ops Engineer
PSC Ops Engineer
25
Performance Monitoring Value
  • PI (1 year)
  • Confirmed 3 trip avoidances
  • Potential 6 trip avoidances
  • Equipment Abnormalities Over 70 abnormalities
    monitored - - - gt long term reliability
  • SmartSignal (3 months)
  • Equipment Abnormalities - 14 identified that
    either returned to normal or communications to
    plant lead to corrective actions. - - - gt long
    term reliability
  • Instrumentation Issues Over 35 identified
    resulting in a potential increase of plant
    reliability. - - - gt long term reliability
  • Efficiency - 2 efficiency catches resulting in
    the scheduling of a water wash and NH3 injection
    reduction.
  • Culture Change
  • PSC has noticed plant personnel are more
    cognizant of equipment abnormalities that are not
    yet urgent.
  • Operational procedures have been modified to
    prevent less than optimal operational conditions.

26

A
Q
Write a Comment
User Comments (0)
About PowerShow.com