Title: Crystal Structure Validation: The IUCr tool to distinguish GOOD and trustable single crystal structures from BAD and UGLY reports
1Crystal Structure ValidationThe IUCr tool to
distinguish GOOD and trustable single crystal
structures from BAD and UGLY reports
- Ton Spek
- Bijvoet Center for Biomolecular Research
- Utrecht University,The Netherlands
- Aachen, Nov 10, 2006
2Who are we ?
- The National facility for small molecule single
crystal structure determination since 1971 in the
Netherlands. - Embedded within the Crystal and Structural
- Chemistry group in Utrecht.
- Also in Utrecht most of the C S research has
moved from small molecule to protein
crystallography (Structural Biology).
3Small molecule and Protein XtallographyUtrecht
4Some Statistics
- Collaboration of the facility with most synthetic
groups in the Netherlands who send their samples
for analysis to Utrecht. - We handled over 3500 requests over the past 35
years. Mainly organometallic and coordination
chemistry. - Up to now, the results are reported in over 1200
(joint) papers.
5People Involved
- The last years 3 to 4 mostly PHDs of which one
on a postdoc position. - Currently a permanent staff of 2 1 postdoc.
- Dr. Martin Lutz (since 1997)
- Dr. Lars von Chrzanowski
- (postdoc since Oct 15, 2006)
- In the past a few trained chemists in the
context of their synthetic work.
6Associated Functions
- Development of crystallographic software based on
local needs PLATON package. - Crystal Structure Validation (IUCr)
- Co-Editor of Acta Cryst. C (involved in the
handling of more than 1000 CIF-formatted papers).
7This Talk
- In this talk I will illustrate with a number of
real world examples how the IUCr structure
validation tool CHECKCIF can help to distinguish
Good from Bad and Ugly crystal structures. - The validation tool was developed in the context
of the journal Acta Cryst. C but is now also used
by many other high standard journals and
pharmaceutical companies. - Let me start with a quote from a Nobel lecture ..
81964 Nobel Lecture Dorothy Hodgkin
- . The great advantage of X-ray analysis as
a method of chemical structure analysis is its
power to show some totally unexpected and
surprising structure with, at the same time,
complete certainty. ..
9With Complete Certainty ?
- Yes, in most cases, in particular in the hands of
experienced investigators. - No, when proper scientific procedures and signs
of trouble have been ignored. - This presentation will address a number of
obvious cases where proper procedures were
ignored, resulting in erroneous science. - There are good scientific reasons for enforcing
an automated validation procedure as illustrated
by the following real world example that
apparently was not properly validated by the
referees.
10THE STABLE PENTAMETHYLCYCLOPENTADIENYL
CATION J.B.Lambert et al. Angew. Chem. Int. Ed.
2002, 41, 1429-1431
11Pentamethylcyclopentadienyl
Common Anionic Form
New Cationic Form
Cp
-
Assigned Bond types
12HOT STRUCTURE FAST LANE PUBLICATION
13Enthusiastic Last Paragraph of CE-News
- The Northwestern chemists are now exploring the
reactivity of C5Me5. You can sit down and write
lots of interesting reactions on paper, Lambert
says, and it will be interesting to see if the
molecule reacts as expected. But Considering this
cations track record, it might be safer to
expect more surprises. !!
14NOT SO HOT AFTER ALL !!
Editors Note in the next issue of Angewandte
Chemie
15Strange Bond Pattern and Ring pucker
DoD
Double Bond ?
PACKING EFFECTS ??
16Corrected StructureJ.N. Jones et al.,Chem. Comm.
2002,1520-1521
Additional H-Atoms
17Where did it go Wrong ?
- First impression of the structure was likely
based on a preliminary result (plot) without
H-atoms. - Rushed as a short communication into the
prestigious high impact journal Angewandte
Chemie. - Ignoring all counter theoretical and
spectroscopic evidence. - No experienced crystallographer as referee ?
- No unbiased automated CIF-validation.
18Validation of the Deposited CIF
?
?
19So Why (Automated) Structure Validation?
- - See previous case study.
- VALIDATION IN THE PAST
- Single crystal structures determined by
experienced professional crystallographers (e.g.
Dorothy Hodgkin) - Using previous generation serial detectors (with
at best an output of 50 datasets/year). - Using (open source) software they knew in detail.
- Structures were analyzed and discussed in great
detail. - Papers containing crystallographic results were
refereed by fellow crystallographers.
20Why Automated Validation?
- PRESENT
- - Diminishing number of professional small
molecule crystallographers (sites, teaching). - Many crystal structures done by chemists
- with limited crystallographic background.
- Using CCD detectors ( 1000 datasets/year when
pushed and given enough slaves). - Crystal structures solved using Black-Box
crystallographic firmware (SHELXTL etc.) - - Near Future AutoCollect AutoSolve
21Why Automated Validation?
- PROBLEMS
- Exploding of structural papers to review.
- Limited of referees with sufficient time and
crystallographic knowledge. - Limited supporting information available
- for the reviewer (footnote/deposited).
- Papers including structural evidence are
increasingly refereed by non-crystallographers,
unaware of the many potential pitfalls.
22SOLUTION
- The solution for the problem was pioneered
by the - International Union of Crystallography
- Provide and archive crystallographic data in the
computer readable CIF format. - Automated validation, with a computer generated
report for authors and referees. - Journals to enforce a structure validation
protocol. - - The IUCr journals and most major journals now
implement validation procedures.
23THE CIF DATA STANDARD
- Driving Force Syd Hall (IUCr/ Acta Cryst C)
- Early Adopted by XTAL SHELX(T)L.
- Currently WinGX,Crystals,Texsan, Maxus etc.
- Acta Cryst. C/E Electronic Submission
- Acta Cryst.Automatic Validation at the Gate
- CIF data available for referees for detailed
inspection (and optional calculations). - Data retrieval from the WEB for published papers
- CCDC Deposition in CIF-FORMAT.
24VALIDATION QUESTIONS
- Single crystal validation addresses three
- important questions
- 1 Is the reported information complete?
- 2 What is the quality of the analysis?
- 3 Is the Structure Correct?
25IUCR-CHECKCIF WEB Service
- IUCR-TESTS
- MISSING DATA, PROPER PROCEDURE, QUALITY
- PLATON TESTS
- SYMMETRY, GEOMETRY, DISPLACEMENT PARAMETERS,
VOIDS, TWINNING etc. - ALERTS
- ALERT A - SERIOUS PROBLEM
- ALERT B - POTENTIALLY SERIOUS PROBLEM
- ALERT C - CHECK EXPLAIN
- ALERT G VERIFY or NOTE
26ALERT TYPES
- 1 - CIF Construction/Syntax errors,
- Missing or Inconsistent Data.
- 2 - Indicators that the Structure Model
- may be Wrong or Deficient.
- 3 - Indicators that the quality of the results
- may be low.
- 4 - Cosmetic Improvements, Queries and
- Suggestions.
27Validation with PLATON
- - Details www.cryst.chem.uu.nl/platon
- Driven by the file CHECK.DEF with criteria, ALERT
messages and advice. - Use platon u structure.cif
- Result on file structure.chk
- Applicable on CIFs and CCDC-FDAT
- FCF-Valid platon V structure.cif
28Problems Addressed by PLATON
- Missed Higher Space Group Symmetry
- Solvent Accessible Voids in the Structure
- Unusual Displacement Parameters
- Hirshfeld Rigid Bond test
- Misassigned Atom Type
- Population/Occupancy Parameters
- Mono Coordinated/Bonded Metals
- Isolated Atoms (e.g. O, H, Transition Metals)
29Problems Addressed by PLATON
- Too Many Hydrogen Atoms on an Atom
- Missing Hydrogen Atoms
- Valence Hybridization
- Short Intra/Inter-Molecular Contacts
- O-H without Acceptor
- Unusual Bond Length/Angle
- CH3 Moiety Geometry
- To be extended with tests for new problems
invented by authors.
30Problems Addressed by PLATON
- Reflection Data (.fcf)
- Sufficient Resolution
- Completeness of the data set
- Missed (Pseudo-) Merohedral Twinning
- Friedel pairs, Absolute Structure
- S
31The Missed Symmetry Problem
- Up to 10 of the structures in space groups such
as Cc have higher symmetry (e.g. C2/c, R-3c, Fdd2
etc.) than was originally reported. - (To be Marshed is not good for your scientific
reputation as a crystallographer). - MISSYM (Y. LePage) PLATON/ADDSYM algorithm
addresses the problem.
32Why is description in a correct space group so
important ?
- Refinement in a too low symmetry group may result
in geometry artifacts - In particular when a centro-symmetric structure
is refined in a non-centrosymmetric space group. - Example of a Bad and Ugly Structure from JACS ?
33Praseodymium complex
J.A.C.S. (2000),122,3413 P1, Z 2
34CORRECTLY REFINED STRUCTURE
P-1, Z2
35The Missed Symmetry Problem
- Another Missed symmetry EXAMPLE from a 2004
Organometallics (23, 3210-3217) paper gt
36(No Transcript)
37(No Transcript)
38Another Missed Symmetry Case
- An example from the space group Cc missed
symmetry family .
39 BAMYEU Dalton Trans 2003,134-140 Cc
40(No Transcript)
41(No Transcript)
42Misoriented O-H
- The O-H moiety is generally, with very few
exceptions, part of a D-H..A system. - An investigation of structures in the CSD brings
up many exceptions. - Closer analysis shows that misplacement of the
O-H hydrogen atom is in general the cause. - Molecules have an environment in the crystal !
- Example ?
43Example of Misplaced Hydrogen Atom
44Two ALERTS related to the misplaced Hydrogen Atom
45Unsatisfactory Hydrogen Bond Network
46(No Transcript)
47(No Transcript)
48Satisfactory Hydrogen Bond Network with new
H-position
49Problem with a Multistep Synthesis
- Example where synthetic chemists were seriously
mislead by the results of an erroneous crystal
structure in an attempt to synthesize a natural
product.
50Characterization of compound isolated from marine
invertebrate
Lindquist et al., J. Amer. Chem. Soc.
(1991),113,2303-2304.
51Synthesis Li et al. (2001) Angew. Chem. 113,
4901 -gtSurprise
Solution of the riddle Li et al. (2001) Angew.
Chem. 113,4906 O --gt N-H (Analysis of the
Displacement Ellipsoids)
52Automatic Validation of the coordinate data taken
from the CSD
Result Alert on short intermolecular OO Contact
53O
N
Infinite hydrogen bonded chain
N-HOC
54Wrong Structures
- Sometimes automatic structure determination
procedures can come up with reasonably looking
but wrong structures. - Structure validation software should send out
proper ALERTS to the investigators - (e.g. IUCr Checkcif)
55Wrong Structure Example
- Structure submitted to Acta Cryst. C
- The chemist involved expects a Cu coordination
complex, so that is what he reports (confirmed
by X-ray crystallography !) - and tries to publish this structure with an
interesting non-coordinated Cu2 - and fortunately caught by the validation software
- ALERTS related to short O..O and O .. N contacts
56R lt 7
Cu not Coordinated gt
ORTEP of the False Structure
57R lt 6
Ortep of the Correct Structure
58Thus
- The original paper indeed mentioned an
interesting uncoordinated Cu2 but left it with
this statement. - The chemistry changed from Cu2L2- to
LBr- by also adding some missed Hydrogen
atoms. - HBr was used in the synthesis (but not mentioned
in the original experimental). - Various ALERTS pointed to the problem but they
were ignored by the authors. - Interestingly, the color of the crystal changed
from green to colorless in the now published
revised paper ..
59Structure Determination Artifacts
- Pseudo-symmetry easily results in false
structures. - Example An Organometallic-AuCl compound from the
CSD with the Cl in the - wrong position ? Very Short C-H..Cl ?!
- ALERTED by validation (C..Cl 2.19 Ang)
- Moving Cl to the correct position drops
- R from 4 to 2
60(No Transcript)
61(No Transcript)
62Consult the CSD
- It is a good idea to always consult the CSD for
previous reports on structures related to the one
at hand. - The statistics provided by VISTA (CCDC) can be
very helpful for this. - However, be aware, such an analysis often shows
outliers. Many of those appear to be errors. - Example A search for short S..S contacts gave
63Entry from the CSD
H
S
64But with Space Group Symmetry
gt Different structure with S-S Bond !
65COMMENTS
- Validation should not be postponed to the
publication phase. All validation issues should
be taken care of during the analysis. - Everything unusual in a structure is suspect,
- mostly incorrect (artifact) and should be
investigated and discussed in great detail and
supported by independent evidence. - - The CSD can be very helpful when looking for
possible precedents (but be careful)
66CONCLUSION 1
- Validation Procedures are excellent Tools to
- Set Quality Standards (Not just on R-Value)
- Save a lot of Time in Checking, both by the
Investigators and the Journals (referees) - - Point at Interesting Features
(Pseudo-Symmetry, - short Interactions etc.) to be discussed.
- Surface a problem that only an experienced
Crystallographer might be able to Address - Proof of a GOOD structure.
67Conclusion 2
- Dorothy Hodgkins claim that X-ray
crystallography can deliver new science is still
valid as it was in 1964, - Given
- Correct procedures
- Structure validation
- Education
68Residual Problem
- EDUCATION
- Response of an author of a structural paper
submitted to the crystallographic journal Acta
Cryst. to an enquiry from a referee on the
reported erroneous space group - Please teach me, what does in mean
- space group incorrect
69Additional Info
- http//www.cryst.chem.uu.nl
- (including a copy of this powerpoint
presentation) - Thanks
- for your attention !!
70(No Transcript)
71(No Transcript)