Phototube response for a multi-element Optical Module - PowerPoint PPT Presentation

1 / 15
About This Presentation
Title:

Phototube response for a multi-element Optical Module

Description:

Phototube response for a multi-element Optical Module A. Mj s H. L hner P. Lubberdink N. Kalantar KVI Groningen in collaboration with NIKHEF Motivation Antares: 10 ... – PowerPoint PPT presentation

Number of Views:51
Avg rating:3.0/5.0
Slides: 16
Provided by: H700
Category:

less

Transcript and Presenter's Notes

Title: Phototube response for a multi-element Optical Module


1
Phototube response for a multi-element Optical
Module
  • A. Mjös
  • H. Löhner
  • P. Lubberdink
  • N. Kalantar
  • KVI Groningen
  • in collaboration
  • with NIKHEF

2
Motivation
  • Antares 10 PM multi-PM configuration 3 PM
  • larger field of view, low noise,
    trigger selectivity

Candidate Photonis XP53x2 (or modification)
produced in large quantities, available
for selection
3
Outline
3 XP53X2
  • PMT Photonis
  • Test Setup
  • Light pulser
  • Analysis
  • Measurements
  • Results
  • Future investigations

3 XP3330
4
(No Transcript)
5
Test Setup
6
LED Light pulser
light intensity variable by LED supply
voltage, neutral-density filters
previous pulser
present pulser
7
charge vs. supply voltage
XP53X2
typ. spread in gain requires selection and
sufficient dynamic range
8
surface sensitivity
XP53X2 at max. gain 4 x 106 (1500 V)
?t ? 1 ns
photocathode area
9
Time over threshold
sufficient sensitivity
10
Charge spectrum
XP53X2 at max. gain 4 x 106 (1500 V)
s.p.e.
dark rate typ. 5 kHz
peak/valley 2.4
charge threshold 0.25 s.p.e.
11
electronic noise / base design
  • 0.11 mV ? 0.05 mV
  • less critical

  • threshold setting

12
10 stage tube XP3330
XP3330 at gain 4 x 106 (1100 V)
peak/valley 2.1
13
Temperature dependence of dark rate
XP3330 at gain 8 x 106 (1200 V)
14
Comparison
should be improved
Peak/valley 2.79
0.46 2.4 2.1

Dark Noise (Hz) 1880 1078
5500 3100 ?150
ideal solution XP53X2 with 10 stages can be
realized within 10 weeks (Photonis offer)
15
Summary
  • Test setup for systematic measurements
  • 3 PM XP53X2 sensitive to s.p.e. at maximum gain
  • Peak/valley 2.4
  • Position and angle-of-incidence dependence
  • over cathode area within 10
  • Time spread over cathode area within 1 ns
  • Time-over-threshold analysis yields 4ns/pC ? 4ns
    / s.p.e.
  • Improvement on dark noise
  • a) voltage-multiplying base for XP53X2 (9
    stage)
  • (in progress at NIKHEF, prototype available)
  • b) use 10-stage PM good results with XP3330
    (150 Hz)
  • Ideal and viable solution XP53X2(10 stage)
Write a Comment
User Comments (0)