Merlin EPU Support and Drive System Design Review - PowerPoint PPT Presentation

1 / 18
About This Presentation
Title:

Merlin EPU Support and Drive System Design Review

Description:

Merlin EPU Support and Drive System Design Review Steve Marks Mark Coleman 4/26/06 Scope of Review - Mechanical System Frame Deflection Bearings and Mounts ... – PowerPoint PPT presentation

Number of Views:98
Avg rating:3.0/5.0
Slides: 19
Provided by: SteveM202
Learn more at: http://www-eng.lbl.gov
Category:

less

Transcript and Presenter's Notes

Title: Merlin EPU Support and Drive System Design Review


1
Merlin EPU Support and Drive System Design Review
  • Steve Marks
  • Mark Coleman
  • 4/26/06

2
Scope of Review- Mechanical System
  • Frame Deflection
  • Bearings and Mounts
  • Deflection
  • Load Rating
  • Drive Screws Load Rating
  • Backing Beams
  • Motor Torques

3
Other Reviews
  • Magnetic structure 2/2/06
  • Motor Control System TBD?
  • Sector 4 EPBI TBD
  • APRP
  • Scope
  • Installation Readiness

4
EPU90 vs. EPU50
EPU50 (old)
EPU90 (new)
5
EPU90 vs. EPU50
EPU90 (new)
EPU50 (old)
6
What is New?
  • 90mm Period (three previous EPUs are50mm)
  • Separate mounting of block/keepers
  • Avoid correlated motion causing shift dependent
    skew quad
  • Modified backing beam
  • Bearings closer to load
  • Horizontal drive closer to load
  • Steel backing beam
  • Stiffer Frame
  • To accommodate 2.3? vertical load
  • Mount encoder directly to backing beams
  • Harmonic drive coupling on vertical screws for
    taper adjustment
  • Modified gear ratio for horizontal drive

7
EPU90
8
EPU90
9
EPU90
10
EPU90
11
Vertical Drive
  • Drive Screws
  • Max. load per screw 17 kN
  • Static load rating 107 kN (static),
  • Mean load 10 kN
  • Dynamic load rating 27 kN (dynamic)
  • Linear Roller Bearings
  • Moment load 2.7 kN-m
  • Rating 7.2 kN-m

12
Vertical Drive
  • Torque/speed
  • Max torque 1.2 N-m
  • Max speed 1500 RPM
  • Motor rating (with EPU50 motor)
  • Cont. Stall Torque 3.9 N-m
  • Rated speed 1500 RPM

13
Deformation due to Vertical Load
14
Vertical Drive
  • Drive screw mounting is over constrained
    -affected by deflection of frame and bearing
    mounts.
  • EPU90 vs. EPU50 Scaling Comparison
  • Vertical columns
  • Vertical load F90/F50 2.3
  • Frame column stiffness I90/I50 6.5
  • Deflection ?90/ ?50 0.35
  • Duplex bearing mounts
  • Moment M90/M50 1.9
  • Stiffness I90/I50 2.0
  • Length L90/L50 0.8
  • Deflection ?90/ ?50 0.67

15
Backing Beam Deflection
16
Backing Beam / Horizontal Drive
Deflection Test Setup
17
Backing Beam / Horizontal Drive
  • Cross Roller Bearings
  • Load per roller 1.0 kN
  • Bearing load rating 3.9 kN
  • Torque/Speed with 5/1 gear ratio (3/1 on EPU50)
  • Max. torque 2.1 N-m
  • Motor rating (using same motor as EPU50)
  • Cont. Stall Torque 3.9 N-m
  • Speed limit 900 RPM ? vmax 10 mm/sec (10
    secs. to switch polarization)

18
Procurement/Fabrication Plan
  • Proceed with procurement of drive screws (long
    lead critical path on schedule)
  • Initiate fabrication of backing beams, frame,
    etc.
  • Proceed with control system procurement after
    control system discussion/review
Write a Comment
User Comments (0)