1
  • N5412A SAS Electrical Performance Validation and
    Compliance Test Software

2
Serial Attached SCSI
  • Small Computer Serial Interconnect (SCSI) just
    got a whole lot smaller, faster more versatile.
  • Performance Gen 1 at 300MBytes/sec per lane
  • Scalability Multi-port, long cables, up to
    1.2GBytes/sec
  • Reliability and Availability Secondary
    failover, P2P
  • Flexibility Supports SAS SATA drives and SCSI
    SW

3
SATA Storage Market Segments
Intel Dell HP Scientific Atlanta ATI Technologies
Adaptec Addonics Technology AMCC Jmicron
Technology LSI Logic Netcell Technology Pacific
Digital Corp. 3Ware
Allion Computer Faraday Technology Corp. Genesys
Logic America Jmicron Technology Corp. LSI
Logic LyCOM Technology NetCell Corporation Panason
ic SILICONSTOR SUNEXT Design STMicroelectronics Ma
rvell Silicon Image
ACARD Technology Corp. Agere Systems Fujitsu
Computer Products Hitachi GST Samsung Seagate STMi
croelectronics Toshiba Western Digital Lite On
Technologies Iomega Corp. Media Tek Inc. Philips
4
SAS Storage Market Segments
5
HDD Interfaces for Multi-user Market
(Gartner Ref. 3)
6
Market Trends
Source http//www.scsita.org
Were primed to meet this major transition from
existing parallel to serial!
7
Market Trends
Tek Compliance Test
Teks solution is based on a 2003 version of the
standard and offers no method of connectivity to
the DUT!
8
Market Trends
Agilent Compliance Test
Tek Compliance Test
Agilents solution is based on the 2005 version
of the standard and directly leverages the
UNH-IOL SAS test suite!!!
9
N5412A is modeled after the industry standard
  • UNH-IOL SAS Test Suite is the industry standard.
  • Interoperability testing starts at the PHY layer.
  • Our solution is complete
  • Minimum of a 10GHz real-time scope
  • Reference test loads and connectivity as per the
    specification
  • Provide common tests and algorithms to the
    UNH-IOL solution

10
Product Definition
  • The N5412A SAS Electrical Compliance Test
    application
  • Supports Gen 1(1.5Gbps) and Gen 2(3Gbps) data
    rates
  • Supports the IT, CT Transmit (TX) interfaces and
    the IR, CR Far-end Transmit (TX) interfaces
  • Provides automated 81134A stimulus for OOB signal
    tests
  • REQUIRES that the PHY (DUT) be able to generate
    CJTPAT, the Compliance Jitter Test Pattern, for
    testing
  • Additionally, Agilent will provide the most
    common x2 internal drive/host test fixture
    (Zero-Length Test Load), Transient Test Fixture
    and Transmitter Compliance Transfer Function
    (TCTF) for the IT compliance point testing.

11
N5412A SAS Electrical Compliance Test Coverage
  • The N5412A SAS Electrical Compliance Tests
  • Maximum/Minimum Rising Time.
  • Maximum/Minimum Falling Time.
  • Eye Inner amplitude(or minimum eye opening).
  • Max peak to peak output amplitude.
  • Maximum Noise during OOB idle time.
  • Maximum transmitter device off voltage.
  • Maximum transmitter output imbalance.
  • OOB offset delta.
  • OOB common-mode delta.
  • Maximum jitter.
  • Maximum skew.
  • Maximum voltage at non-operational.
  • Minimum OOB burst amplitude.
  • Maximum Transients.
  • Bit Rate.

12
SAS Compliance Points
13
SAS Interface Connector Descriptions
Type        Section     Ref. pg.    Connector ref.    Interface Name Interface Name Interface Name      
Internal    5.2.3.2.1   pg. 98      SFF-8482          SAS x2 Internal Plug Connector SAS x2 Internal Plug Connector SAS x2 Internal Plug Connector SAS x2 Internal Plug Connector    
Internal    5.2.3.2.2   pg. 98      SFF-8482          SAS x2 Internal Cable Receptacle SAS x2 Internal Cable Receptacle SAS x2 Internal Cable Receptacle SAS x2 Internal Cable Receptacle    
Internal    5.2.3.2.3   pg. 99      SFF-8482          SAS x2 Internal Backplane Receptacle SAS x2 Internal Backplane Receptacle SAS x2 Internal Backplane Receptacle SAS x2 Internal Backplane Receptacle SAS x2 Internal Backplane Receptacle  
                   
Int. Wide   5.2.3.4.2   pg. 108     SFF-8484          SAS x4 Internal Wide Cable Receptacle Connector SAS x4 Internal Wide Cable Receptacle Connector SAS x4 Internal Wide Cable Receptacle Connector SAS x4 Internal Wide Cable Receptacle Connector SAS x4 Internal Wide Cable Receptacle Connector SAS x4 Internal Wide Cable Receptacle Connector
Int. Wide   5.2.3.4.3   pg. 109     SFF-8484          SAS x4 Internal Wide Plug Connector SAS x4 Internal Wide Plug Connector SAS x4 Internal Wide Plug Connector SAS x4 Internal Wide Plug Connector    
Int. Wide   5.2.3.4.5   pg. 111     SFF-8087/86       SAS x4 Internal Compact Wide Plug Connector SAS x4 Internal Compact Wide Plug Connector SAS x4 Internal Compact Wide Plug Connector SAS x4 Internal Compact Wide Plug Connector SAS x4 Internal Compact Wide Plug Connector  
Int. Wide   5.2.3.4.6   pg. 112     SFF-8087/86       SAS x4 Internal Compact Wide Receptacle Connector SAS x4 Internal Compact Wide Receptacle Connector SAS x4 Internal Compact Wide Receptacle Connector SAS x4 Internal Compact Wide Receptacle Connector SAS x4 Internal Compact Wide Receptacle Connector SAS x4 Internal Compact Wide Receptacle Connector
                   
External    5.2.3.3.2   pg. 101     SFF-8470          SAS x4 External Cable Plug Connector SAS x4 External Cable Plug Connector SAS x4 External Cable Plug Connector SAS x4 External Cable Plug Connector SAS x4 External Cable Plug Connector  
External    5.2.3.3.3   pg. 101     SFF-8470          SAS x4 External Receptacle Connector SAS x4 External Receptacle Connector SAS x4 External Receptacle Connector SAS x4 External Receptacle Connector SAS x4 External Receptacle Connector  
External    5.2.3.3.5   pg. 103     SFF-8088/86       SAS x4 External Compact Cable Plug Connector SAS x4 External Compact Cable Plug Connector SAS x4 External Compact Cable Plug Connector SAS x4 External Compact Cable Plug Connector SAS x4 External Compact Cable Plug Connector  
External    5.2.3.3.6   pg. 104     SFF-8088/86       SAS x4 External Compact Receptacle Connector SAS x4 External Compact Receptacle Connector SAS x4 External Compact Receptacle Connector SAS x4 External Compact Receptacle Connector SAS x4 External Compact Receptacle Connector SAS x4 External Compact Receptacle Connector
14
SFF-8482 SAS x2 Internal Connectors
SFF-8482 Plug (Drive/Backplane / IT Interface)
SFF-8482 Cable Receptacle / IR Interface
15
SFF-8484 SAS x4 Internal Connectors
SFF-8484 Plug (HBA / IT Interface)
SFF-8484 Cable Receptacle / IR Interface
16
SFF-8470 SAS x4 External Connectors (
SFF-8470 Plug (Inter-Enclosure / CR Interface)
SFF-8470 External Receptacle / CT Interface
17
Simplistic Single-Port Server Configuration
  • A SATA host is analogous to a SAS initiator
    device a SATA device is analogous to a SAS
    target device. Compliance is defined at the
    connectors for both buses.

Connector Topology SATA x1 connector
receptacle SAS Host SFF-8482 receptacle SAS
Device SFF-8482 receptacle
18
Simplistic 4-Port Server Configuration
  • A 4-port SAS controller (host bus adapter,
    usually PCI-X or PCIe to SAS) will have an
    internal x4 connector, and will fan out to four
    individual x1 connectors on SATA or SAS drives.
    In this case, only the primary port will be used
    and the secondary port remains unused.

Connector Topology SAS Host SFF-8484
receptacle SAS Device SFF-8482 receptacle
19
SAS Test Fixture Requirements
  • In general, SAS compliance testing will require
  • An adapter from the SAS connector to SMA
  • A TCTF (omitted for ZLTL tests)
  • A termination network (provided by scope 50-ohm
    terminations OR Transient Test Circuit)

20
SAS x1 Internal (IT) Zero-Length Test Load
Far End Test Fixture (cable) H303000102 iSATA
Text Fixture (Cable)
Near End Test Fixture (Drive, HBA) H303000202
iSATA Test Fixture (Drive/Host)
Used for physical layer electrical impedance
tests
Used for cable impedance tests
Available From CRUZ Systems (Worldwide
Distribution)Internet www.cruzsystems.com
21
SAS x2 Internal (IT) Zero-Length Test Load TCTF
Available now! N5421A SFF-8482 Test Fixture
3000 US DDP
22
SAS x4 External (CT) Zero-Length Test Load
Available From Gore as IBNTST4X for 3800
23
SAS x4 External (CT) TCTF
Available From Molex upon request