1
EXPERIMENTAL RESULTS OBTAINED IN SMALL WIND
TURBINES TEST PLANT. NEW PROPOSALS FOR THE
MEASUREMENTS
Luis Cano Santa Bárbara CIEMAT-CEDER (Spain)
2
  • INDEX
  • Background.
  • CIEMATs SWT activities.
  • National RD Project. (PSE Miniéolica).
  • Results.
  • Analysis.
  • Proposals to the measurements.
  • Conclusions.

3
  • BACKGROUND
  • CIEMATs SWT activities is being carried out
    since 1998.
  • Capacities
  • Power Performance Test (in accordance with IEC
    61400-121).
  • Noise Emission Test (in accordance with IEC
    61400-11).
  • Duration Test. (in accordance with IEC 61400-2).
  • Safety and Function Test. (in accordance with
    IEC 61400-2).
  • SWT Components Test (p.e. Blades, generator,
    etc).
  • Other tests interesting for the SWT research.
  • Hybrid systems based on Small Wind Turbines.
    Evaluation, study and design control strategies
    (PV-Wind and Wind Diesel systems).

4
  • FACILITIES
  • Test Facility Phase I, (PEPA I) SWT up to 6
    kW.
  • Test Facility Phase II, (PEPA II) SWT up to 20
    kW.
  • Test Facility Phase III, (PEPA II) SWT up to
    100 kW. (under construction).
  • Blades Test Bench. Nominal length 1 to 10 m.
  • Generators Test Bench. Up to 100 kW (under
    construction).
  • New building for the study of SWT integration
    in the architecture (under construction).

5
  • FACILITIES PEPA I

100m Mast
Wind Pumping
Central building
Wind-diesel system
  • 100 m height anemometer mast.
  • Wind pumping system.
  • Wind-diesel system.
  • Central building.
  • 4 Test positions.
  • Battery bank up to 300 V.
  • Uninterrupted Monitored System up to 128
    channels.
  • Different Loads to simulate consumes.
  • Inverters/chargers SWT test versatility.

6
  • FACILITIES PEPA II
  • Inverter Test.
  • Study of Isolated Hybrid Systems or connected to
    Weak Grids.
  • Possibility of installation, design and
    characterization of new systems based on Wind
    Energy desalination, wind-hydrogen, etc.
  • Study of quality of energy in generators
    connected to the grid.
  • 5 Test Positions up to 20 kW.

7
FACILITIES PEPA III
  • Wind Turbines Grid integration.
  • Possibility of installation, design and
    characterization of new systems based on Wind
    Energy desalination, wind-hydrogen, etc.
  • 8 Test Positions up to 200 kW.

8
FACILITIES BLADE TEST BENCH
Blades from 3 to 10 m
Blades from 1 to 3 m
  • Static Test.
  • Proper Frequencies Study.
  • Fatigue Test (under construction).

9
FACILITIES GENERATORS TEST BENCH
Control and monitoring system
Electronic Loads
Drive motor
Torque measurement
Small Generator
  • Different test to generators in accordance with
    Standards IEC 60034.
  • Efficiency.
  • Voltage-Current Curves.

10
FACILITIES NEW BUILDING
UNDER CONSTRUCTION
  • Vibrations and noise.
  • Study of the behaviors of SWT on the rooftops.
  • Comparison and demonstration of different
    technologies.

11
  • National RD Project. PSE- MINIEOLICA
  • Objective
  • Reduce the installed cost of SWT to 1500 /kW.
    (p.e. large series manufacturing, fast blades
    manufacturing process, development of control
    systems, inverters, etc.).
  • Energy production cost 10-15 c/kWh with wind
    speed of 5-6 to 10 m/s.
  • Increase the SWT reliability to achieve a 90 of
    availability.
  • Dynamize the SWT market. Target. 100 MW
    installed in a medium period.
  • Establish the certification and homologation
    procedures and centers.
  • Rise the Spanish SWT exportations.

12
  • National RD Project. PSE- MINIEOLICA
  • Subprojects in which CIEMAT is involved
  • SP 1.2Active yaw power regulation SWT.
  • SP 1.3 Development of high performance and low
    cost SWT of 25/50/75 kW, with pitch control and
    variable speed.
  • SP 2.1 Design and Evaluation of Rotors.
  • SP 2.2 Development of multipurpose systems to
    regulate, control and supervise SWT generation
    systems.
  • SP 3.1 Measure and Test all the Spanish
    commercial SWTs.
  • SP 3.2 EOLMAP. Spanish Wind Map for SWT
    installers and end users.
  • SP 3.6 SWTs Standardization.

13
National RD Project. PSE- MINIEOLICA SP 3.1
Measure and Test all the Spanish commercial SWTs.
SWT Power Performance Noise Duration Safety
Bornay 1500/24 On going
Bornay 3000/48 On going
Windeco VENTO 5000/48 On going
Bornay 3000/24 On going - - -
Solener VELTER III On going - - -
Solener VELTER X On going - - -
14
National RD Project. PSE- MINIEOLICA Results
Bornay Inclin Neo 1500
HIGH UNCERATINTY
SOME POINTS ARE OUT FIGURE
15
National RD Project. PSE- MINIEOLICA Results
Bornay Inclin Neo 3000
DOUBLE REGULATION?
LESS UNCERTAINTY
16
National RD Project. PSE- MINIEOLICA Results
WINDECO VENTO 5000
BAD CONTROL STRATEGY
17
  • National RD Project. PSE- MINIEOLICA
  • Analysis
  • Significant variations has been detected between
    the measurements obtain and the expected ones
    (above all in the AEP curve).
  • Its important to define quite well the
    regulation system in case of active control.
  • The results in noise emissions should be better
    in case of a massive installation.
  • A vibration analysis could be recommended in
    case of mounting over rooftops.

18
  • Proposals
  • Background
  • It seem that the results are nor exactly what
    its expected.
  • That could mean, there would be several variables
    dont take into account (p.e. turbulence,
    obstacles, etc).
  • AEP Curve is one the most important data for the
    costumers.
  • The results in these curves are very uncertain in
    low wind speed.
  • The cost of tests are very high for the
    manufacturer.

19
  • Proposal
  • The SWT labeling could be a very good idea for
    the market.
  • In this way, it should be necessary international
    initiatives, for example the IEC WG2 for 61400-2
    new edition and IEA Task 27 liaison to get
    better procedures to certificate and labeling
    future SWT.
  • Fitting curves in all the tests could be an
    interesting possibility to reduce the cost.
  • Noise emission test defined in the IEC 61400-11
    is defined to Wind Farms, not in an urban site
    (p.e.)

20
Proposal Fitting curves. One line of work.
Average wind machine power
Electrical power
Weibull probability density
Test obtained
21
  • Conclusions
  • CIEMAT is making significant efforts to promote
    the increase of the reliability of Spanish
    commercial SWT.
  • Some new initiatives to produce advanced local
    wind turbines in a range around 100 kW are being
    widely considered.
  • It should be needed to focus more investigations
    on the measurements of the SWTs and their
    components.
  • Its necessary to develop new tools for the
    manufacturers training.
  • The actual measurement procedures should be more
    reliable. An important way for research is
    opened.
  • An effort on the standardization and/or labeling
    to carry out a friendly useful output for the end
    user and it should be made in a short period of
    time.

22
THANK YOU VERY MUCH FOR YOUR ATTENTION
CEDER-CIEMAT LUIS CANO. luis.cano_at_ciemat.es Tel.
34975281013 Ext 324 Autovía A-15. Salida
56 42290 Lubia. SORIA (SPAIN)