Arch 330 - PowerPoint PPT Presentation

1 / 99
About This Presentation
Title:

Arch 330

Description:

... ** (Vapor retarder on warm side of insulation) Insulation: Between Deck and Membrane Rigid panels of insulation, light weight concrete. – PowerPoint PPT presentation

Number of Views:86
Avg rating:3.0/5.0
Slides: 100
Provided by: Katherin179
Category:
Tags: arch | concrete | light | weight

less

Transcript and Presenter's Notes

Title: Arch 330


1
Arch 330 Thermal Moisture Protection Roofing
Systems
2
Roofing Systems
  • 073000 Steep Slope Roofing
  • Shingles and Shakes
  • Roof Tiles
  • Natural Roof Coverings
  • 074000 Roofing and Siding Panels
  • Roof and Wall Panels
  • Siding
  • 075000 Membrane Roofing
  • 076000 Flashing Sheet Metal
  • 077000 Roof and Wall Specialties and Accessories

3
Division 7
  • 078000 Fire and Smoke Protection
  • 079000 Joint Protection
  • Joint Sealants and Expansion Control

4
(No Transcript)
5
Low Slope - Disadvantages
  • water drains slowly
  • standing water can cause deterioration
  • structural movement - tear the membrane.

6
Low Slope - Advantages
  • can cover building of any horz. dimension
  • can serve as
  • balconies, decks, patios, landscaped gardens.

7
(No Transcript)
8
Item Spotted Flat roof Observations This is
not a good roof design for wet climates. There is
constantly puddles of water on the top of this
roof. Location PEB, WSU Campus
  • Name Kallen Hawthorne ID 10596914

9
Steep Slope
  • drains quickly
  • can be covered with roofing material of small
    overlapping units
  • - shingles of wood
  • - slate
  • - artificial composition
  • - tiles of fired clay or concrete
  • - bundles of reeds (thatch).

10
Steep Slope
  • Thermal expansion / contraction minimized
  • Movement in structure is minimized
  • - by the ability of small units to move with -
    respect to one another.
  • Water vapor vents from the interior through the
    loose joints in the roofing material.

11
Item Spotted A combination of a flat and gamble
roof Observations This building has a very
interesting skyline because of the combination
roof. However if one was to look closely at the
picture, one con see puddles of standing water.
Location Smith Gym, WSU Campus
  • Name Kallen Hawthorne ID 10596914

12
(No Transcript)
13
(No Transcript)
14
(No Transcript)
15
LOW SLOPE ROOF(not FLAT) lt 312 pitch
  • Min Slope  
  • 1/8 per 1-0 or 1100
  • 1/4 per 1-0 or 150

16
Low lt 312 pitch
3
1/4
  • 12

17
Roof Slope
  • Slope Roof to direct water towards drainage
    points
  • - counter-acting structural deflection.
  • Depending on size of deck expansion joints should
    be provided to
  • - control expansion and contraction and
  • - satisfy requirements of membrane.
  • Membrane should be laid on flat surface.

18
FLAT ROOF - COMPONENTS 
  • DECK
  • THERMAL INSULATION
  • VAPOR RETARDER
  • MEMBRANE
  • FLASHINGS
  • DRAINAGE COMPONENTS

19
DeckTypes of structural deck used for low slope
roof
  • Plywood over wood joists
  • Solid wood decking over heavy timber framing
  • Corrugated steel decking
  • Panels of wood fiber bonded together with
    portland cement
  • Poured gypsum over insulating formboard
  • Sitecast concrete and precast concrete

20
(No Transcript)
21
(No Transcript)
22
  • Insulating Deck Boards wood/glass fibers
  • Truss Tee Purlins slab of gypsum/lt wt conc

23
Thermal Insulation
  • Below the Deck
  • Between Deck Membrane
  • Above the Membrane

24
Thermal Insulation Below the Deck
  • Leaves the deck and membrane exposed to full
    range of temperature.
  • Batt insulation of glass fiber or mineral fiber
    between wood joists
  • - or on top of a suspended ceiling assembly.
  • Vapor retarder below insulation
  • (Vapor retarder on warm side of insulation)

25
Insulation Between Deck and Membrane
  • Rigid panels of insulation, light weight
    concrete.
  • Protects deck from temperature extremes.
  • Membrane subjected to extreme temperature
    variations.
  • Moisture trapped in insulation can damage
    insulation and deck.
  • Place vapor retarded on inside of insulation and
    vent insulation to release moisture.

26
Insulation Above the Membrane
  • Membrane protected - extremes of temperature.
  • Membrane on warm side of insulation - immune to
    vapor blistering.
  • Insulation must be a material which is not
    effected by wet and will not disintegrate -
    extruded polystyrene board
  • Insulation board adhered in bed of hot asphalt or
    laid loose.
  • Layer of ballast laid over insulation.

27
Insulation Above the Membrane
  • Ballast
  • - crushed stone
  • - thin concrete layer factory laminated to upper
    surface of
    insulation board
  • - interlocking concrete blocks.
  • Membrane ages little protected from sunlight and
    temperature extremes - despite presence of
    moisture.
  • Rigid insulation - mechanical fix to deck
    preferable.

28
Insulation above the Membrane Other names for
this system
  • Inverted roof
  • Upside down roof
  • Protected membrane roof,
  • - 20years old

29
Vapor Retarder
  • 2 sheets asphalt saturated roofing felt
  • In cold climate on warm side of insulation.
  • In hot humid climate/with air conditioning - on
    outer side of insulation

30
Membrane
  • Built up roof membrane
  • Single-ply roof membrane
  • Fluid-applied roof membrane

31
Built-up membrane
  • 2-4 Layers/ plies of felt
  • asphalt impregnated, bedded in bitumen
  • felt cellulose fibers/glass fibers asphalt
  • Felt laminated in overlapping layers
  • Layer of aggregate (crushed stone)

32
Built-Up Membrane
  • Bitumen - asphalt derived
  • For low pitch roofs - coal tar bitumen or
    coal-tar pitch used-
  • - greater resistance to standing water
  • Asphalt and coal tar are applied hot

33
  • Aggregate
  • Insulation
  • Felt
  • Conc. Deck
  • Aggregate
  • Felt
  • Insulation x 2
  • Metal Deck

34
  • 4 ply felt hot asphalt

35
Single Ply Roof membrane
  • Single layer
  • More elastic - less cracking/tearing
  • Fixing adhesives, ballast, concealed fasteners,
    mechanical fasteners.
  • Protective coating

36
Single Ply Roof Membrane
  • EPDM , synthetic rubber
  • (ethylene propylene diene monomer) 
  • NEOPRENE (polychloroprene)
  • synthetic rubber compound 
  • PVC (polyvinyl chloride)
  • vinyl - thermoplastic compound

37
  • Single-Ply Membrane

38
  • Aluminum Faced
  • Single-Ply Membrane

39
Fluid Applied Membrane
  • domes, vaults, complex shapes
  • roller or spray gun, applied
  • several coats - rubbery membrane.

40
Built-Up Single PlyBallast
  • loose stone aggregate
  • precast concrete blocks.
  • Ballast holds the membrane in place against wind
    uplift
  • Protects membrane from ultraviolet light and
    physical wear.
  • Increase the fire resistance of the roof
    covering.

41
Traffic Decks-walks, terraces, parking on low
slope roof
  • Heavy square paving slabs or stones open joints
  • on blocks of plastic or conc on roof membrane
  • (b) Open Jointed Paving Blocks on A drainage
    layer of gravel or porous concrete leveled over
    the membrane
  • Water falls through the joints and is drained
    away by the membrane below
  • Membrane is not pierced.

42
Structural Standing Seam Metal Roofing for Low
Slope Roofs
  • Proprietary systems of standing seam metal
    roofing
  • Used as low slope roofs - 1/4" in 12 "(148).
  • The folded shape - stiffness - support itself
    a normal snow load between purlins without the
    need for structural deck below.

43
(No Transcript)
44
(No Transcript)
45
(No Transcript)
46
(No Transcript)
47
(No Transcript)
48
(No Transcript)
49
  • Mechanical Fix
  • Through Insulation to Deck below

50
  • Hot Application of Layers

51
  • Stone ballast on Insulation on Membrane

52
(No Transcript)
53
  • Mechanical Fix

54
(No Transcript)
55
(No Transcript)
56
Steep Slope gt312 pitch
11.25º
3
  • 12

57
Steep Slope gt312 pitch
  • Drains quickly,
  • Small overlapping units - Shingles
  • Expansion and contraction and movement
  • Water vapor vents

58
Steep Slope Roof Systems3 Categories of
Covering
  • Thatch
  • Shingles wood, asphalt, slate, clay/conc
  • Sheet Metal lead, copper, terne, aluminum

59
Steep Sloped Roof Systems
  • Typically insulation and vapor retarder installed
    below the roof sheeting or deck.
  • Underside of deck is exposed as a finished
    surface
  • - vapor retarder and rigid insulation above the
    deck below roofing layer of plywood (nailed over
    the insulation panels as a nail base for
    fastening shingles or sheet metal).

60
Insulation
Steep Sloped Roof Typically insulation and vapor
retarder installed below the roof sheeting or
deck.
61
Insulation
Steep Sloped Roof Underside of deck is exposed as
a finished surface
62
Flashing _at_ all junctions
63
Thatch
  • Bundles of reeds, grasses or leaves,
  • Labor intensive
  • Highly insulative
  • Attractive
  • Codes limit its use
  • Not fire resistant

64
(No Transcript)
65
Shingles
  • Small size unit, applied to roof in overlapping
    layers - staggered vertical joints
  • wood shingles/ shakes
  • asphalt shingles
  • slates
  • clay tiles and concrete tiles.
  • PV photovoltaic

66
Shingles
  • Each type of shingle, slate or tile must be laid
    on a roof deck - that slopes sufficiently to
    assure leak-proof performance.
  • Min. slope for each material are specified by the
    manufacturer and code

67
Wood Shingles
  • Thin, tapered slabs of wood, SAWED from short
    pieces of tree trunk
  • Grain parallel to the face of the shingle.

68
(No Transcript)
69
(No Transcript)
70
Wood Shakes
  • Split not sawn
  • Rough face texture,
  • North US - wood shingles/ shakes are Red cedar,
    White cedar,
  • Redwood - natural decay resistance.
  • Wood roof covering moderately expensive, not
    highly resistant to fire unless pressure treated
    with fire retardant chemicals.

71
(No Transcript)
72
Asphalt Shingles
  • Asphalt impregnated felt - faced with mineral
    granules.
  • Die cut from sheet, typical size 12" x 36".
  • Slotted twice - smaller unit.
  • Inexpensive, quick to install, moderately fire
    resistant.
  • Expected life time of 15 to 25 years.
  • Laid on asphalt saturated felt paper in two
    layers.

73
(No Transcript)
74
(No Transcript)
75
(No Transcript)
76
(No Transcript)
77
(No Transcript)
78
(No Transcript)
79
Slate
  • Split, trimmed to size and punched or drilled for
    nailing.
  • Fire resistant,
  • long lasting,
  • relatively expensive,
  • laid in over lapping layers.

80
(No Transcript)
81
(No Transcript)
82
(No Transcript)
83
Tiles Clay, Concrete
  • Glazed and unglazed
  • Concrete less expensive than clay roof tile.
  • Typically heavy
  • Durable
  • Highly resistant to fire
  • Expensive in first cost

84
(No Transcript)
85
(No Transcript)
86
(No Transcript)
87
Architectural Sheet Metal Roofing
  • Relatively high in first cost
  • Last for many decades.
  • Galvanic action should be avoided in the roof
    installation.
  • Beware of water run-off also re galvanic action
    from one metal to another.

88
(No Transcript)
89
  • Seaside, Gulf Coast The Truman Show

90
(No Transcript)
91
(No Transcript)
92
  • Strawbale, Potlatch, Idaho

93
(No Transcript)
94
Lead, Copper Sheet
  • Used since ancient times.
  • Self-protecting metal - last many decades.
  • Installed in sheets using systems of joining and
    fastening
  • Maintain water tightness at the seams.
  • Seams especially standing batten seams create a
    strong visual pattern.

95
Lead, Copper Sheet
  • Lead oxidizes to a white color.
  • Copper turns blue-green in clear air, black in an
    industrial atmosphere.
  • Chemical treatments and coatings can be applied
    to preserve a desired color.

96
Other Sheet Metals
  • Aluminum,
  • Zinc Alloys,
  • Stainless Steel Sheet Metal Roofing
  • Can be used in same way as copper, lead and terne

97
(No Transcript)
98
(No Transcript)
99
(No Transcript)
Write a Comment
User Comments (0)