Tri-Tech Medical Inc. - PowerPoint PPT Presentation

1 / 59
About This Presentation
Title:

Tri-Tech Medical Inc.

Description:

Title: Tri-Tech Medical Author: Jim Lucas Last modified by: LEE OECHSLE Created Date: 5/31/2005 7:02:16 PM Document presentation format: On-screen Show (4:3) – PowerPoint PPT presentation

Number of Views:450
Avg rating:3.0/5.0
Slides: 60
Provided by: jiml77
Category:
Tags: diamond | inc | medical | nfpa | tech | tri

less

Transcript and Presenter's Notes

Title: Tri-Tech Medical Inc.


1
Tri-Tech Medical Inc.
  • Medical Gas Outlets

2
Medical Gas Outlets
  • DISS
  • Ohmeda style
  • Allied style
  • Puritan style
  • Recessed wall
  • DISS Recessed ceiling
  • Surface wall
  • Console / Headwall
  • Ambulance / Surgical Arm

3
Common Backs
  • Recessed/Console
  • 360º swivel inlet tube
  • 1/2 OD copper tubing
  • Accommodates all styles of Outlet Latch Plates
  • ETL listed
  • Ambulance/ Surgical Arm
  • 360º swivel inlet tube
  • DISS or hose barb
  • Accommodates all styles of Outlet Latch Plates
  • ETL listed

4
DISS Outlets
  • Frontall design
  • Gangable
  • Full faceplate color coding
  • 5 inch centers
  • Primary secondary checks
  • 360 positioning of extension tube

5
DISS Surface Outlets
  • Frontall design
  • Full faceplate color coding
  • Primary secondary checks

6
Frontall Feature
  • Allows routine service of both the primary and
    secondary check valves without removing the
    nameplate or gas specific portions.
  • Very fast easy to service
  • Primary check cartridge

7
Repairing DISS Front Bodies
  • These parts would be ordered separately
  • Cartridge (Negative and Positive gases)
  • Primary Check Seat and Ball Check (Positive gases
    only)
  • Chrome-Plated Body

8
Ohmeda Style Outlets
9
Ohmeda Style Outlets
  • Accepts Ohmeda gas specific compatible male
    adaptors
  • Gangable
  • 5 centers
  • Allows routine service of both the primary and
    secondary check valves.
  • Full faceplate color coding

10
Ohmeda Style Surface Outlet
  • Accepts Ohmeda gas specific compatible male
    adaptors
  • Allows routine service of both the primary and
    secondary check valves.
  • Full faceplate color coding

11
Repairing Ohmeda style fronts
  • Remove screws
  • Remove body and plate

12
  • U-clip and washer remain.
  • Front body and plate

13
  • Replace body
  • Replace plate and screw

14
XQ1000-D Ohmeda style Front Latch Body
  • Can be ordered as an assembly, or in parts

15
Allied Style Outlets
16
Allied Style Outlets
  • Accepts Allied style gas specific compatible male
    adapters
  • Gangable, 5 centers
  • Full faceplate color coding
  • 1/2 OD copper tubing
  • Metal back and front plates
  • 360º swivel inlet tube

17
Allied Style Surface Outlets
  • Accepts Allied gas specific compatible male
    adapters
  • Full faceplate color coding

18
Repairing an Allied Style Front
  • Remove screws
  • Remove body and plate

19
  • Place body on housing and replace plate
  • Position o-ring and washer on new body

20
  • Replace Screws

21
XA1000-D Front Latch Body
  • Can be ordered as an assembly, or in parts

22
Puritan Style Outlets
23
Puritan Style Outlets
  • Accepts Puritan style gas specific compatible
    male adapters
  • Gangable, 5 centers
  • Full faceplate color coding
  • 1/2 OD copper tubing
  • Metal back and front plates
  • 360º swivel inlet tube

24
Puritan Style Outlets
  • Accepts Puritan gas specific compatible male
    adapters
  • Full faceplate color coding

25
Repairing a Puritan Style Front
  • Using manual screwdriver, remove screws
  • Remove body and small plate

26
  • Remove ONLY these parts

27
  • Screw plate back in place with Manual
    screwdriver.
  • Do not over tighten
  • Replace parts or entire body

28
XP1000-E Puritan Latch Body
  • Can be ordered as an assembly or in parts

29
Console / Headwall Outlets
  • Available in DISS, Ohmeda, Puritan and Allied
    styles
  • DISS style includes Frontall features
  • Full faceplate color coding
  • Optional trim plate available

30
Console / Headwall Outlets
31
Console / Headwall Outlets
32
Ambulance / Surgical Arm Outlets
  • Available in DISS and Quick Connect styles
  • DISS and hose barb inlet connections
  • DISS includes Frontall features
  • Full faceplate color coding

33
DISS x ¼ npt outlets and DISS x hose barb
outlets
34
Fairfield Rail
35
Fairfield Rail Outlets
  • Three different styles

36
Outlet Conversion Kits
37
Conversion Kits
38
Conversion Kit - Disassembly
39
Conversion Kits - Disassembly
40
Conversion Kits - Installation
41
Trim Plates
  • Single gang through six gang
  • Large array of on center spacing
  • Can be customized to meet your needs

42
Ohmeda to Ohmeda Conversion Kits
  • Available for Diamond I to Diamond III
  • Available for Diamond II to Diamond III
  • Easy to install
  • Easy to service

43
Other Ohmeda Conversion Kits
  • Available for Melco/Foregger/Linde 9/16-18 and
    Chemetron/NCG to Diamond III
  • Easy to install and service

44
(No Transcript)
45
(No Transcript)
46
(No Transcript)
47
(No Transcript)
48
  • NFPA 99 REQUIREMENTS FOR
  • STATION OUTLETS/INLETS TRI-TECH PRODUCT
  • GAS SPECIFIC YES
  • STATION OUTLET TO HAVE PRIMARY AND SECONDARY
    CHECK YES
  • STATION INLET TO HAVE PRIMARY CHECK (SECONDARY
    CHECK PERMITTED) YES
  • SECONDARY VALVE TO CLOSE WHEN PRIMARY VALVE IS
    REMOVED YES
  • EACH OUTLET/INLET LEGIBLY IDENTIFIED ACCORDING TO
    5.1.11.3 YES
  • THREADED OUTLETS/INLETS SHALL COMPLY WITH CGA V-5
    (DISS) YES
  • STATION OUTLET/INLET COMPONENTS THAT ARE GAS
    SPECIFIC
  • NOT INTERCHANGEABLE YES
  • COPPER TUBES ON STATION OUTLETS SHALL BE 3/8 OD
    MIN

49
Tri-Tech Medical Inc.
  • Gas Control Panels and
  • Gas Control Panel Conversion Kits

50
Gas Control Panel
  • Stainless steel front
  • Self-relieving regulator
  • Frontall DISS outlet features
  • High quality ball valve
  • Painted steel rough-in box
  • 2 Inlet outlet pressure gauges

51
(No Transcript)
52
  • MIDAS REX EQUIPMENT
  • APPROX 5 OF TOOLS IN FIELD ARE OLDER TOOLS
    REQUIRING 50 - 200 PSI - 900 CFH - 425 LPM
  • NEW TOOLS REQUIRE
  • 20 - 120 PSI - 720 CFH - 340 LPM
  • OR 481 CFH - 227 LPM
  • NITROGEN CONTROL PANEL
  • MAXIMUM FLOW CAPACITY BASED ON 180 PSI INLET
  • FLOWING TO ATMOSPHERE
  • STATIC DEL FLOW FLOW DEL PRESS
  • PRESSURE PSIG SCFH LPM FLOWING PSIG
  • 100 930 440 96
  • 110 1030 486 106
  • 120 1110 524 114
  • 130 1150 543 119
  • 150 1175 555 120
  • 170 1180 557 120

53
Gas Control Panel Conversion
  • Converts existing panels by several major brands
  • Same features as our regular panel
  • Easy to install using a universal mounting plate
    over existing back box

54
Gas Control Panel Conversion
  • Existing back box

55
Gas Control Panel Conversion
  • Installing conversion connections

56
Gas Control Panel Conversion
  • Installing conversion plate

57
Gas Control Panel Conversion
  • Back of the front panel conversion

58
Gas Control Panel Conversion
  • Connecting tube

59
Gas Control Panel Conversion
  • Installing gas control panel
Write a Comment