Cooling Tower Vibration Monitoring - PowerPoint PPT Presentation

1 / 17
About This Presentation
Title:

Cooling Tower Vibration Monitoring

Description:

... 12 Accelerometers or Velocity Motor and ... Times New Roman Arial Calibri Verdana Default Design Bitmap Image Cooling Tower Vibration ... – PowerPoint PPT presentation

Number of Views:548
Avg rating:3.0/5.0
Slides: 18
Provided by: Gin144
Category:

less

Transcript and Presenter's Notes

Title: Cooling Tower Vibration Monitoring


1
Cooling Tower Vibration Monitoring
2
Closed Loop Cooling Tower System
3
Types of Mechanical Draft Towers
4
Typical Power Plant
5
Cooling Towers At Nuclear Plants
6
Cooling Tower Critical Components
  • Fans
  • Gear Boxes
  • Motors

7
Cooling Tower Failures - Blades
8
Cooling Tower Failures - Gearboxes
9
Cooling Tower Application Issues
  • Towers are very flexible
  • High vibration values during startup.
  • Complex gearbox (1800/120 RPM)
  • Neighboring cells effect measurement
  • Starting cell 2 can shut down cell 1
  • Reversing fans in cold climates
  • Water build up in blades
  • Speeds are slow and based on diameter
  • Distance to control room
  • Corrosion from bad pH

10
Existing Earthquake Sensors
  • Calibrated by dropping sledgehammer
  • Do not always trip
  • Some use Ball and Pedestal
  • Operators do not like climbing the tower
  • Alarm value usually set to high to help
  • No provision for Startup (Tx)
  • No OK Circuit

11
CMCP-500 Series Monitoring
  • Transmitter or Monitor
  • 24 VDC Powered
  • Trip Multiply Standard
  • OK Circuit
  • ADC Option
  • RF Link option
  • Fiberglass or SS NEMA 4X Enclosures

12
12 Cell Cooling Tower Monitoring System
  • Typical Rotating Machinery and Sensors
  • Circulating Water Pumps (2)
  • 6 Accelerometers
  • 4 Eddy Probe Systems
  • 2 Phase
  • Cooling Tower Pumps (2)
  • 6 Accelerometers
  • Gearbox and Fan (12)
  • 12 Accelerometers or Velocity
  • Motor and Jackshaft (12)
  • 12 Accelerometers (Output Shaft)

13
10 Cell Cooling Tower Monitoring System
14
Dual Path Monitoring
  • Displacement (mils)
  • Running speed (1X)
  • Blade passing
  • Blade multiples
  • Velocity (in/sec)
  • Gear mesh
  • Bearings

15
Dual Path Monitoring System
  • CMSS793V Transducer
  • CMCP-602L-32-01-01 Cable
  • CMCP-5302 Monitoring System w/
  • CMCP-530-100V-02R-XXX-XXX
  • 0 to 1.0 in/sec (0 to 25 mm/sec)
  • CMCP-535-100V-03-XXX-XXX
  • 0 to 15 mils (0 to 375 microns)

16
Circulating Water Pumps
17
Where are the Cooling Towers ?
  • Power Generation
  • Steam
  • Nuclear
  • Geothermal
  • Hydrocarbon Processing (HPI)
  • Refineries
  • Chemical Plants
  • Food Processing
  • Tropicana
  • Campbell Soup
  • Large Buildings (HVAC)
Write a Comment
User Comments (0)
About PowerShow.com