Title: MEDIUM VOLTAGE VFD MOTOR CONTROLLER


1
MEDIUM VOLTAGE VFD MOTOR CONTROLLER
  • Liquid Cooled Components
  • Active Front End - No Transformer
  • 3300 6900 VAC
  • 700 2500 HP

www.system-controls.net
Contact sales_at_system-controls.net
2
Single 1000 HP, 4160 VAC Motor Controller with
Rubber Tire Option
3
4160 Volt VFD Underground Motor Controller
  • Skid-Mounted Continuous Weld Design
  • Input and Output Couplers Standard
  • Rubber Tire Option

4
4160 Volt VFD Underground Motor Controller
  • Voltages from 3300 to 6900 AC
  • Horsepowers from 750 to 2500
  • Regenerative Applications Standard
  • Constant Torque Duty 150 Overload Standard
  • Custom Design Allows for 250 Overload

5
PowerFlex 7000 Kit
  • Rockwell Automation PowerFlex 7000 Liquid-Cooled
    Direct-to-Drive kit packaged for Underground Use

Liquid Cooled Rectifier and Inverter
6
PowerFlex 7000
  • Active Front End (AFE) is Regenerative - Standard
  • AFE means no Integral Transformer Required
  • Direct-to-Drive (D2D) means 4160 vac In and 4160
    vac Out to Motor
  • Liquid Cooled Components Stay Cooler and Cleaner
    Longer Life
  • Reduces Harmonics on Electrical System

7
Liquid Cooling for Longer Life!
  • Closed-Loop De-Ionized Liquid Cooling
  • Integral Flat Plate Heat Exchanger Keeps
    Closed-Loop System Clean and Contained

8
Liquid Cooling for Longer Life!
  • Flange Fittings for Mine Cooling Water Input and
    Hot Water Return
  • Redundant Pumps for Ease of Maintenance
  • Controls Monitor Temperature, Pressure, and
    Conductivity of Cooling Liquid

DC Link Choke
9
Underground Mining Equipment VFD Motor Controls
  • Face Conveyor and Stageloader Applications
  • Torque and Speed Control
  • Enhanced Overload Capacity

10
Underground Mining Equipment VFD Motor Controls
  • Allows Face Conveyor to Operate at Reduced
    Speeds
  • Minimizes Chain Wear by up to 40
  • Reduces Energy Costs
  • Extends Time Between Rebuilds

11
Underground Mining Equipment VFD Motor Controls
  • Extreme Overload Capabilities
  • PowerFlex 7000 Kit May be Customized
  • Normal Duty at 110, Heavy Duty at 150
  • Mine Duty up to 280 Overload for 20 Seconds of
    Each 120 Seconds
  • 6.6 kv Rectifiers with Oversized DC Link Choke
    and Input Line Reactor

12
Underground Mining Equipment VFD Motor Controls
  • Modular Liquid Cooled Design
  • Used in Multiple Motor Configurations, Add or
    Remove Motors as Required
  • Separate Controls in Skid or Wall Mounted
    Configuration
  • Closed Loop Liquid Cooling System Keeps VFD
    Cooler and Cleaner for Increased Life and
    Reliability
  • Motor Leads Up to 10 KM

13
4160 Volt VFD for Underground Belt Conveyor
Controls
  • Modular Design Provides Flexibility in Number of
    Motors Used
  • Main or Booster Applications
  • Torque and Speed Control

14
4160 Volt VFD for Underground Belt Conveyor
Controls
  • Unlimited Conveyor Start Time Minimizes Belt
    Tensions
  • Minimizes HP Required and Conveyor Component
    Sizes
  • Reduces TakeUp Requirements
  • Extends Belt Life

15
4160 Volt VFD for Underground Belt Conveyor
Controls
  • Allows Conveyor to Operate at Reduced Speeds
  • When Less Than Design TPH is Required Conveyor
    Speed May Be Reduced
  • Belt Inspection Speed for Maintenance

16
4160 Volt VFD for Underground
  • Modular Liquid Cooled Design
  • Used in Multiple Motor Configurations, Add or
    Remove Motors as Required
  • Separate Belt Controls in Skid or Wall Mounted
    Configuration
  • Closed Loop Liquid Cooling System Keeps VFD
    Cooler and Cleaner for Increased Life and
    Reliability

17
4160 Volt VFD for Underground
  • Lowers Electrical Harmonics
  • Active Front End Provides Regenerative Ability
  • Active Front End Meets IEEE-519 Requirements
  • SGCT Devices Use Slower Switching Frequencies
    Reducing Common Mode Noise
  • Eliminates Need for Drive Isolation Transformers
  • Eliminates Harmonics Damage to Electrical
    Distribution Equipment
  • Motor Lead Lengths Up to 10 KM

18
4160 Volt VFD for Underground
  • Reduces Installation Cost of Low Voltage
  • Saves on Cable Cost
  • Smaller Cables Reduce Installation Time
  • For 400 of Cabling
  • Saves Over 70,000 in Cable Cost
  • Requires Less Than 1/3 of Time to Install or Move

19
MEDIUM VOLTAGE VFD MOTOR CONTROLLER
  • Liquid Cooled Components
  • Active Front End - No Transformer
  • 3300 6900 VAC
  • 700 2500 HP

www.system-controls.net
Contact sales_at_system-controls.net