Rotor Bar % Continuity Tests Using the El-Cid Equipment. (Highlights of over 290 tests) - PowerPoint PPT Presentation

1 / 22
About This Presentation
Title:

Rotor Bar % Continuity Tests Using the El-Cid Equipment. (Highlights of over 290 tests)

Description:

Rotor Bar % Continuity Tests Using the El-Cid Equipment. (Highlights of over 290 tests) J McMurdo The Extreme Rotor Bar Types Material: Copper Brass Aluminium ... – PowerPoint PPT presentation

Number of Views:496
Avg rating:3.0/5.0
Slides: 23
Provided by: JackMc8
Category:

less

Transcript and Presenter's Notes

Title: Rotor Bar % Continuity Tests Using the El-Cid Equipment. (Highlights of over 290 tests)


1
Rotor Bar Continuity Tests Using the El-Cid
Equipment.(Highlights of over 290 tests)
  • J McMurdo

2
The Extreme
  • Major Damage to
  • Rotor Winding
  • Rotor Core
  • Stator Core
  • Stator Winding

3
Rotor Bar Types
  • Material
  • Copper
  • Brass
  • Aluminium
  • Silicon-Bronze
  • Steel
  • Bar profile
  • T
  • L
  • Rectangular
  • Round
  • Pyramid
  • Square.

4
Approaching the Extreme
Bars de-brazed from s/c ring, eroded through the
slot bridge, Being rubbed down by contact with
the stator core
5
Broken Rotor Bars
Numerous broken bars, erosion of slot bridges in
progress
6
Inadequate Brazing A
7
Inadequate Brazing B
8
Bar Continuity and Core Losses
No evidence of correlation between in-phase bar
continuity and quadrature measurement of
core losses
9
Good
10
One Low Indication Localised Repair Possible
11
Numerous Low IndicationsMajor Repairs Indicated
12
Steel Bars to Copper Short Circuit Rings A
13
Steel Bars to Copper Short Circuit Rings B
14
Induction Techniques
  • Work using the Wissink tester first performed
    at Bonnycan and refined during the Authors
    continued development work at GEC / Alstom and
    Wadeville AW
  • Induction coil growler combined with El-Cid
    equipment to qualify starting condition 50hz

15
Die-Cast Aluminium Rotor Outer Cage
16
Die-Cast Aluminium Rotor Inner Cage
17
Die-Cast Rotor BarCombined Profile
18
El-Cid Technique
  • Direct applied current
  • Measurement using the Rogowski coil (Chattock
    potentiometer) coreless, non-inductively wound
    sensor.
  • In-phase measurement rather than quadrature
  • Technique differentiates between
  • broken bars and
  • poor bar to short circuit ring joints

19
El-Cid Technique (contd)
  • Accuracy Calibrated to within 0.5
  • Repeatability Bar 1 hard stamped, bar 2
    stamped to confirm progression

20
El-Cid Technique
Phase Sensor
21
Conclusion
  • Rotor bar problems still occur
  • Testing at the assessment stage is of value in
    preventing the Extreme
  • Re-test to prove efficacy after repairs
  • End-user operational feedback is required to
    maximise value

22
The Extreme
Major Damage to Rotor Winding Rotor Core Stator
Core Stator Winding
Acknowledgement This presentation was produced
in collaboration with Ron Scollay
Write a Comment
User Comments (0)
About PowerShow.com