Electric Imaging of Myocardial Ischemia - PowerPoint PPT Presentation

About This Presentation
Title:

Electric Imaging of Myocardial Ischemia

Description:

Electric Imaging of Myocardial Ischemia Rob MacLeod, Bonnie Punske, Shibaji Shome, Bulent Yilmaz, and Bruno Taccardi Cardiovascular Research and Training Institute – PowerPoint PPT presentation

Number of Views:101
Avg rating:3.0/5.0
Slides: 38
Provided by: RobMa62
Learn more at: http://www.sci.utah.edu
Category:

less

Transcript and Presenter's Notes

Title: Electric Imaging of Myocardial Ischemia


1
Electric Imaging of Myocardial Ischemia
  • Rob MacLeod, Bonnie Punske,
  • Shibaji Shome, Bulent Yilmaz, and Bruno Taccardi

Cardiovascular Research and Training
InstituteBioenginering DepartmentUniversity of
Utah
2
Origins
Occlusion
Pre-PTCA
Peak-PTCA
3
Biophysics of Acute Ischemia
4
Imaging Approach
5
Cardiac Mapping of Ischemia
LAD
LCx
Epicardium
Endocardium
Source of Electrocardiographic ST Changes
in Subendocardial Ischemia Li et al. Circ. Res.
82957-970, 1998
6
Research Questions
  • ST elevation or (transient) depression?
  • Acute occlusion versus graded flow?
  • How do ST changes image on the body surface?

7
Technical Apparatus
  • Andy III
  • 370 electrodes
  • R 500 W cm
  • Homogeneous
  • 1024 channel acquisition

8
Isolated Heart Preparation
Electrolytic Torso Tank
Flow Regulators
Heat Exchange
C
J
Support Dog
Epicardial Sock Electrodes
TorsoTank Electrodes
9
Flow Control
10
Epicardial Electrode Sock
  • Nylon stocking material
  • 490 recording wires
  • 24 pacing wires
  • Reference markers for geometry

11
Protocols
  • Acute, complete occlusion
  • 3-minute duration
  • measurements each 30 s
  • Graded flow
  • 2-minute intervals at each flow rate
  • measurement at end of each interval
  • Graded heart rate
  • constant flow rate
  • increase rate in 2-minute intervals
  • measurement at end of each interval

12
Data Processing
  • Signals (Everett)
  • gain correction, windowing, baseline correction
  • global fiducials (Qon, Soff, Toff)
  • Geometry
  • location of sock in tank
  • coronaries
  • Maps (Matlab, Map3d)
  • integrals QRS, QRST, ST, STT, ST80

13
Signal Processing
3/8
5/8
80ms
Qon
Toff
Soff
SToff
ST80
14
Tank/Heart Geometry
15
Acute Occlusion??ST
Flow
Time
30
300
270
24
240
210
18
180
150
12
120
90
6
60
30
0
s
ml/min
4Jan01-ocl1
16
Graded Flow??QRS
30 ml/m
24 ml/m
18 ml/m
12 ml/m
6 ml/m
0 ml/m
10Jan01-ocl1
17
Graded Flow??ST
30 ml/m
24 ml/m
18 ml/m
12 ml/m
6 ml/m
0 ml/m
10Jan01-ocl1
18
Graded Pacing ? ST80
(reduced flow)
34 ml/m
215
24 ml/m
190
18 ml/m
165
12 ml/m
150
6 ml/m
130
0 ml/m
Flow
Heart Rate
10Jan01-ocl4
19
Graded Pacing??ST80
(full flow)
34 ml/m
215
24 ml/m
190
18 ml/m
165
12 ml/m
150
6 ml/m
130
0 ml/m
Flow
Heart Rate
10Jan01-ocl5
20
Fixed Rate, Decreased Flow
  • Start flow at 35
  • Reduce to 0
  • Increase back to 35
  • 3 minutes at each flow rate

21
ReducedFlow??ST-80
Flow
Time
35
28
21
14
7
0
ml/min
min
19Jan01-ocl1
22
ReducedFlow??ST-80
Flow
Time
33
35
30
27
28
24
21
21
18
15
14
12
9
7
6
3
0
ml/min
min
19Jan01-ocl1
23
ReducedFlow??ST-80
Flow
Time
33
35
30
27
28
24
21
21
18
15
14
12
9
7
6
3
0
ml/min
min
19Jan01-ocl1
24
ReducedFlow??ST-80
Flow
Time
33
35
30
27
28
24
21
21
18
15
14
12
9
7
6
3
0
ml/min
min
19Jan01-ocl1
25
ReducedFlow??ST-80
Flow
Time
33
35
30
27
28
24
21
21
18
15
14
12
9
7
6
3
0
ml/min
min
19Jan01-ocl1
26
ReducedFlow??ST-80
Flow
Time
33
35
30
27
28
24
21
21
18
15
14
12
9
7
6
3
0
ml/min
min
19Jan01-ocl1
27
ReducedFlow??ST-80
Flow
Time
33
35
30
27
28
24
21
21
18
15
14
12
9
7
6
3
0
ml/min
min
19Jan01-ocl1
28
ReducedFlow??ST-80
Flow
Time
33
35
30
27
28
24
21
21
18
15
14
12
9
7
6
3
0
ml/min
min
19Jan01-ocl1
29
ReducedFlow??ST-80
Flow
Time
33
35
30
27
28
24
21
21
18
15
14
12
9
7
6
3
0
ml/min
min
19Jan01-ocl1
30
ReducedFlow??ST-80
Flow
Time
33
35
30
27
28
24
21
21
18
15
14
12
9
7
6
3
0
ml/min
min
19Jan01-ocl1
31
ReducedFlow??ST-80
19Jan01-ocl1
32
ReducedFlow??ST-80
19Jan01-ocl1
33
Fixed Flow, Increased Rate
  • Start flow at 35
  • Reduce to 21
  • Increase rate

34
Increased Rate??ST-80
Flow
Time
Rate
35
18
231
15
214
28
12
200
21
9
188
14
6
176
7
3
167
0
158
ml/min
min
BPM
19Jan01-ocl1
35
Increased Rate??ST-80
Flow
Time
Rate
35
18
231
15
214
28
12
200
21
9
188
14
6
176
7
3
167
0
158
ml/min
min
BPM
19Jan01-ocl1
36
Increased Rate??ST-80
Flow
Time
Rate
35
18
231
15
214
28
12
200
21
9
188
14
6
176
7
3
167
0
158
ml/min
min
BPM
19Jan01-ocl1
37
Increased Rate??ST-80
Flow
Time
Rate
35
18
231
15
214
28
12
200
21
9
188
14
6
176
7
3
167
0
158
ml/min
min
BPM
19Jan01-ocl1
38
Increased Rate??ST-80
Flow
Time
Rate
35
18
231
15
214
28
12
200
21
9
188
14
6
176
7
3
167
0
158
ml/min
min
BPM
19Jan01-ocl1
39
Increased Rate??ST-80
Flow
Time
Rate
35
18
231
15
214
28
12
200
21
9
188
14
6
176
7
3
167
0
158
ml/min
min
BPM
19Jan01-ocl1
40
Increased Rate??ST-80
Flow
Time
Rate
35
18
231
15
214
28
12
200
21
9
188
14
6
176
7
3
167
0
158
ml/min
min
BPM
19Jan01-ocl1
Write a Comment
User Comments (0)
About PowerShow.com