Title: Comparison of MultiSpeak Connectivity Model and the IEC CIM NetworkDataSet


1
Comparison of MultiSpeak Connectivity Model and
the IEC CIM NetworkDataSet
  • Gary A. McNaughton
  • Cornice Engineering, Inc.

2
Outline
  • Background on MultiSpeak and CIM
  • Why MultiSpeak and CIM should be harmonized
  • How harmonization can occur
  • MultiSpeak and CIM power system data models

3
Standards for Integration of Distribution
Applications
  • MultiSpeak
  • Developed by NRECA in collaboration with key
    industry vendors
  • Covers applications of interest to distribution
    utilities currently doesnt include power
    scheduling or generation
  • Standard is mature, but scope is continuing to
    grow
  • In use at over 200 utilities
  • Mature interoperability testing program, applies
    to all interfaces
  • Uses XML web services and batch transport
    profiles defined
  • More information and specification available at
    www.MultiSpeak.org

4
Standards for Integration of Distribution
Applications
  • CIM with Distribution Extensions
  • Maintained by IEC Technical Committee 57
  • Scope is larger than MultiSpeak, but is less
    mature
  • Implementations based on CIM data model in place
    at dozens of utilities
  • Implementation is messaging-based and transport
    agnostic, currently no transport profiles defined
  • Interoperability testing is in place for two
    limited profiles (transmission and distribution
    power system model exchange)
  • Core CIM in IEC 61970 distribution extensions in
    IEC 61968

5
MultiSpeak Point-to-Point Architecture
Prepaid Metering (PPM)
32
16
Payment Processing (PP)
33
Dynamic GIS Viewer (DGV)
11
Staking
Finance Accounting (FA)
31
29
Customer Relationship Management (CRM)
Static GIS Viewer (SGV)
21
28
Customer Billing (CB)
12
GIS
14
Call Handling (CH)
22
24
19
7
23
2C
2B
2A
Engineering Analysis (EA)
SCADA
4
8
Meter Reading (MR)
Load Profile (LP)
6
15
10
18
Connect/Disconnect (CD)
27
Outage Analysis (OA)
Outage Detection (OD)
5
9
25
Load Management (LM)
3
26
30
1
6
MultiSpeak Services Bus Architecture
7
Point-to-Point Outage Handling Example
8
Outage Handling Example - Bus Architecture
2x
9
Why Harmonize MultiSpeak and CIM?
  • Both standards have value and likely will
    co-exist in market
  • Both standards will undoubtedly be simultaneously
    implemented in some utilities
  • Inter-company messaging will likely be required
    among companies using different standards

10
Steps in Harmonization
  • Map MultiSpeak web service methods to WG14 CIM
    messages (use case steps).
  • Compare WG14 and MultiSpeak data payloads for
    each use case step.
  • Create electronic data payload transformation.
  • Create adapter layer to handle data
    transformation and messaging conversion.

11
Harmonization Example
  • Map MultiSpeak web service methods to WG14 CIM
    messages. Choose network connectivity
  • Compare WG14 and MultiSpeak data payloads for
    each use case step.
  • Create electronic data payload transformation.
  • Create adapter layer to handle data
    transformation and messaging conversion.

12
Harmonization Example
  • Map MultiSpeak web service methods to WG14 CIM
    messages.
  • Compare WG14 and MultiSpeak data payloads for
    each use case step. Compare MultiSpeak
    Connectivity and CIM NetworkDataSet payloads
  • Create electronic data payload transformation.
  • Create adapter layer to handle data
    transformation and messaging conversion.

13
Sample Distribution Circuit
14
Basic Differences
  • MultiSpeak can handle section-oriented or node
    oriented models CIM uses nodes.
  • CIM can have terminals associated with nodes
    MultiSpeak does not have terminals.
  • MultiSpeak does not explicitly model ground.
  • One terminal devices have an implied ground.
  • Three terminal devices are modeled with two
    terminals and implied ground.

15
MultiSpeak and CIM Equivalence
16
Fuse Equivalence Peeling the Onion
  • CIM Fuse contains more than MultiSpeak fuse
  • Equivalent is MultiSpeak overcurrentDeviceBank
    containing fuse units.
  • MultiSpeak overcurrentDeviceBank contains more
    than a CIM Fuse
  • Missing parts are in SwitchProperties child of
    the Fuse.
  • CIM Fuse w/ SwitchProperties has more than
    MultiSpeak OCD w/ fuses
  • Missing parts are in eaEquipment catalog

17
Steps in Harmonization
  • Map MultiSpeak web service methods to WG14 CIM
    messages (use case steps).
  • Compare WG14 and MultiSpeak data payloads for
    each use case step.
  • Create electronic data payload transformation.
  • Create adapter layer to handle data
    transformation and messaging conversion.

18
(No Transcript)
19
Steps in Harmonization
  • Map MultiSpeak web service methods to WG14 CIM
    messages (use case steps).
  • Compare WG14 and MultiSpeak data payloads for
    each use case step.
  • Create style sheet data payload transformation.
  • Create adapter layer to handle data
    transformation and messaging conversion.

20
Conclusions
  • CIM and MultiSpeak are both complete, consistent
    data models for distribution modeling
  • There are stylistic differences reflecting the
    needs and perspectives of the modelers
  • The models are symantically and topologically
    equivalent
  • It is possible to electronically convert payloads
    between the data models
  • The two data models can co-exist if desirable

21
For More Information
  • Technical Contact Program Contact
  • Gary A. McNaughton Bob Saint
  • Cornice Engineering, Inc. NRECA
  • P.O. Box 2350 4301 Wilson Blvd.
  • Pagosa Springs, CO 81147 Arlington, VA 22203
  • Phone (970) 731-1508 (703) 907-5863
  • gmcnaughton_at_corniceengineering.com
    Robert.Saint_at_nreca.coop
  • www.MultiSpeak.org
Write a Comment
User Comments (0)
About PowerShow.com