Lecture 21 Bar Development - PowerPoint PPT Presentation

1 / 51
About This Presentation
Title:

Lecture 21 Bar Development

Description:

Bars must be extended on each side of section to develop bar force at that section. ... Total bar length = Fully effective ... Bar Cutoffs - General Procedure ... – PowerPoint PPT presentation

Number of Views:76
Avg rating:3.0/5.0
Slides: 52
Provided by: ericsa3
Category:

less

Transcript and Presenter's Notes

Title: Lecture 21 Bar Development


1
Lecture 21 - Bar Development
  • October 18, 2002
  • CVEN 444

2
Lecture Goals
  • Bar Cut-off Points
  • Spice

3
Bar Cutoff Points
Why do you want to put in cut off points?
Economy!
4
Bar Cutoff Points
Factors Affecting Bar Cut-off Points
5
Bar Cutoff Points
Factors Affecting Bar Cut-off Points
6
Bar Cut of Points
Factors Affecting Bar Cut-off Points
7
Determining Locations of Flexural Cutoffs
Given a simply supported beam with a distributed
load.
8
Determining Locations of Flexural Cutoffs
Note Total bar length Fully effective length
Development length
9
Determining Locations of Flexural Cutoffs
ACI 12.10.3 All longitudinal tension bars must
extend a min. distance d (effective depth of
the member) or 12 db (usually larger) past the
theoretical cutoff for flexure (Handles
uncertainties in loads, design approximations,etc.
.)

10
Determining Locations of Flexural Cutoffs
Development of flexural reinforcement in a
typical continuous beam. ACI 318R-95

11
Bar Cutoffs - General Procedure
Determine theoretical flexural cutoff points for
envelope of bending moment diagram. Extract the
bars to satisfy detailing rules (from ACI Section
7.13, 12.1, 12.10, 12.11 and 12.12) Design extra
stirrups for points where bars are cutoff in zone
of flexural tension (ACI 12.10.5)
1. 2. 3.
12
Bar Cutoffs - General Rules
All Bars Rule 1. Rule 2.
Bars must extend the longer of d or 12db past the
flexural cutoff points except at supports or the
ends of cantilevers (ACI 12.11.1)
Bars must extend at least ld from the point of
maximum bar stress or from the flexural cutoff
points of adjacent bars (ACI 12.10.2 12.10.4 and
12.12.2)
13
Bar Cutoffs - General Rules
Positive Moment Bars Rule 3.
  • Structural Integrity
  • Simple Supports At least one-third of the
    positive moment reinforcement must be extend 6
    in. into the supports (ACI 12.11.1).
  • Continuous interior beams with closed stirrups.
    At least one-fourth of the positive moment
    reinforcement must extend 6 in. into the support
    (ACI 12.11.1 and 7.13.2.3)

14
Bar Cutoffs - General Rules
Positive Moment Bars Rule 3.
  • Structural Integrity
  • Continuous interior beams without closed
    stirrups. At least one-fourth of the positive
    moment reinforcement must be continuous or shall
    be spliced near the support with a class A
    tension splice and at non-continuous supports be
    terminated with a standard hook. (ACI 7.13.2.3).

15
Bar Cutoffs - General Rules
Positive Moment Bars Rule 3.
  • Structural Integrity
  • Continuous perimeter beams. At least one-fourth
    of the positive moment reinforcement required at
    midspan shall be made continuous around the
    perimeter of the building and must be enclosed
    within closed stirrups or stirrups with 135
    degree hooks around top bars. The required
    continuity of reinforcement may be provided by
    splicing the bottom reinforcement at or near the
    support with class A tension splices (ACI
    7.13.2.2).

16
Bar Cutoffs - General Rules
Positive Moment Bars Rule 3.
  • Structural Integrity
  • Beams forming part of a frame that is the primary
    lateral load resisting system for the building.
    This reinforcement must be anchored to develop
    the specified yield strength, fy, at the face of
    the support (ACI 12.11.2)

17
Bar Cutoffs - General Rules
Positive Moment Bars Rule 4.
  • Stirrups
  • At the positive moment point of inflection and at
    simple supports, the positive moment
    reinforcement must be satisfy the following
    equation for ACI 12.11.3. An increase of 30 in
    value of Mn / Vu shall be permitted when the ends
    of reinforcement are confined by compressive
    reaction (generally true for simply supports).

18
Bar Cutoffs - General Rules
Positive Moment Bars Rule 4.
19
Bar Cutoffs - General Rules
Negative Moment Bars Rule 5.
  • Negative moment reinforcement must be anchored
    into or through supporting columns or members
    (ACI Sec. 12.12.1).

20
Bar Cutoffs - General Rules
Negative Moment Bars Rule 6.
  • Structural Integrity
  • Interior beams. At least one-third of the
    negative moment reinforcement must be extended by
    the greatest of d, 12 db or ( ln / 16 ) past the
    negative moment point of inflection (ACI Sec.
    12.12.3).

21
Bar Cutoffs - General Rules
Negative Moment Bars Rule 6.
  • Structural Integrity
  • Perimeter beams. In addition to satisfying rule
    6a, one-sixth of the negative reinforcement
    required at the support must be made continuous
    at mid-span. This can be achieved by means of a
    class A tension splice at mid-span (ACI
    7.13.2.2).

22
Moment Resistance Diagrams
Moment capacity of a beam is a function of its
depth, d, width, b, and area of steel, As. It is
common practice to cut off the steel bars where
they are no longer needed to resist the flexural
stresses. As in continuous beams positive moment
steel bars may be bent up usually at 45o, to
provide tensile reinforcement for the negative
moments over the support.
23
Moment Resistance Diagrams
The nominal moment capacity of an
under-reinforced concrete beam is To determine
the position of the cutoff or bent point the
moment diagram due to external loading is drawn.
24
Moment Resistance Diagrams
The ultimate moment resistance of one bar, Mnb
is The intersection of the moment resistance
lines with the external bending moment diagram
indicates the theoretical points where each bar
can be terminated.
25
Moment Resistance Diagrams
Given a beam with the 4 8 bars and fc3 ksi and
fy50 ksi and d 20 in.
26
Moment Resistance Diagrams
The moment resistance of one bar is
27
Moment Resistance Diagrams
The ultimate moment resistance is 2480 k-in. The
moment diagram is drawn to scale on the basis A
bar can be terminated at a, two bars at b and
three bars at c. These are the theoretical
termination of the bars.
28
Moment Resistance Diagrams
It is necessary to develop part of the strength
of the bar by bond. The ACI Code specifies that
every bar should be continued at least a distance
d, or 12db , which ever is greater, beyond the
theoretical points a, b, and c. Section 12.11.1
specify that 1/3 of positive moment reinforcement
must be continuous.
29
Moment Resistance Diagrams
Two bars must extend into the support and moment
resistance diagram Mur must enclose the external
bending moment diagram.
30
Example Cutoff
For the simply supported beam with b10 in. d
17.5 in., fy40 ksi and fc3 ksi with 4 8 bars.
Show where the reinforcing bars can be
terminated.
31
Example Cutoff
Determine the moment capacity of the bars.
32
Example Cutoff
The minimum distance is
33
Example Cutoff
The minimum amount of bars are As/3 or two bars
34
Example Cutoff
Determine the location of the bar intersections
of moments.
35
Example Cutoff
Determine the location of the bar intersections
of moments.
36
Example Cutoff
The resulting moment-resistance diagram is
37
Bar Splices
38
Tension Lap Splices
39
Types of Splices
40
Types of Splices
Class B Spice
(ACI 12.15.2)
All tension lay splices not meeting requirements
of Class A Splices
41
Tension Lap Splice (ACI 12.15)
where As (reqd) determined for bending ld
development length for bars (not allowed
to use excess reinforcement modification
factor) ld must be greater than or
equal to 12 in.
42
Tension Lap Splice (ACI 12.15)
Lap Spices shall not be used for bars larger than
No. 11. (ACI 12.14.2) Lap Spices should be placed
in away from regions of high tensile stresses
-locate near points of inflection (ACI 12.15.1)

43
Compression Lap Splice (ACI 12.16)
44
Compression Lap Splice (ACI 12.16)

45
Example Splice Tension
46
Example Splice Tension
For 8 bars, db 1.0 in and a b g l 1.0
47
Example Splice Tension
The As(provided) /As(required) gt 2, class A
splice applies therefore lst 1.0 ld gt12 in.,
so lst 43 in. gt 12 in. The bars spliced are
less than half the number
The As(provided) /As(required) lt 2, class B
splice applies therefore lst 1.3 ld gt12 in.,
so lst 1.3(42.4 in.) 55.2 in. use 56 in. gt 12
in..
Class B splice applies and lst 56 in. gt 12 in.
48
Example Splice Compression
Calculate the lap splice length for a 10
compression bar in tied column when fc 5 ksi and
when a) fy 60 ksi and b) fy 80 ksi
49
Example Splice Compression
For 10 bars, db 1.27 in.
Check ls gt 0.005 db fy 38.1 in. So ls 39 in.
50
Example Splice Compression
For 10 bars, db 1.27 in. The ld 23 in.
Check ls gt (0.0009 fy 24) db
(0.0009(80000)-24)(1.27in.) 61 in. So use ls
61 in.
51
Homework
Problem 10.3 Problem 10.4
Write a Comment
User Comments (0)
About PowerShow.com