Series F4S and F4D 14 DIN Ramping Controllers - PowerPoint PPT Presentation

1 / 72
About This Presentation
Title:

Series F4S and F4D 14 DIN Ramping Controllers

Description:

Output follows a set of user instructions (profile) ... F or C, Degree, and decimal point indication. Operations display. 4 line X 20 characters per line ... – PowerPoint PPT presentation

Number of Views:37
Avg rating:3.0/5.0
Slides: 73
Provided by: roger211
Category:

less

Transcript and Presenter's Notes

Title: Series F4S and F4D 14 DIN Ramping Controllers


1
Series F4S and F4D 1/4 DIN Ramping Controllers
2
(No Transcript)
3
Watlows Next Generation Styling
Series V4T 1/4 DIN Temperature Controller
Series 97 Matching 1/16 DIN Limit Controller
Series F4S and F4D Ramping Controller
4
F4 Ramping Controllers
  • F4S Single Channel Ramping
  • Single channel temperature or process control
    with profile capability
  • F4D Dual Channel Ramping
  • Allows temperature and humidity control in one
    package

5
What Is a Ramping Controller?
Output follows a set of user instructions
(profile), to automatically adjust or hold set
point for different time periods.
6
Ramping or Fixed Set Point Operation
  • Ramp and Soak Programmable Control
  • Control operation automatically follows a set
    (profile) of preprogrammed instruction to perform
    a processing task.
  • Static Set Point Control
  • Operator intervention is required when processing
    changes are needed.

7
F4 Ramping Controller Focus Markets
8
Environmental Chambers
  • Applications
  • Product thermal cycling
  • Laboratory chambers
  • Product analysis
  • Product storage

9
Furnaceand Oven
  • Applications
  • Heat Treating
  • Kilns
  • Autoclaves
  • Foundry Metal Processing

10
Electronic Components and Assembly
  • Semiconductor processing equipment
  • Electronic assembly equipment

11
Other FocusIndustries
  • Applications
  • Analytical Instruments
  • Glass Manufacturing and Annealing
  • Incubators

12
Ease of Use
The most important selection factor following
quality and reliability when selecting a
temperature controller is ease of use.

Source1997 VDC Worldwide Market Report for
Industrial Electronic Temperature Controllers
13
Enhanced Display and Keypad
  • Ramping control programming made easy through
    advanced technology
  • Icons for international applications
  • Read-at-a-glance process display
  • Full message prompting of operation and setup

14
F4 Operator Interface
  • Primary process display
  • Large 5-digit, 7-segment displays
  • 0.562 (14.3mm) display digit height
  • F or C, Degree, and decimal point indication
  • Operations display
  • 4 line X 20 characters per line
  • High definition back lit LCD
  • Wide viewing angle

15
F4 Operator Interface
  • 6 operator interface keys
  • Rubber key switch with tactile feel
  • 4 navigational keys
  • Parameter and value selection with arrow keys
  • i information key
  • Toggle for Help
  • Profile key - initiate or hold profile operation

16
F4 Operator Interface
  • Discrete LED indicators
  • Control output indication
  • Alarm active indication
  • Communications activity
  • Profile indication

17
Multilingual Prompts
  • Available in multiple languages
  • English
  • German
  • French
  • Spanish

18
Advanced Hardware Features
  • 20 MHz operation, 16-bit processor
  • NEMA 4X sealed front panel
  • Shallow 4 (101mm) overall case depth
  • FLASH memory for field software update

19
F4 Industrial Design Features
  • High strength injection molded case
  • 3.85 (97.8 mm) behind panel depth
  • Ergonomic design styling
  • Compatible with Series 96 97 limit
  • NEMA 4X front panel seal
  • Convenient 4 screw installation brackets

20
F4 Industrial Design Features
  • Touch safe wiring termination
  • Removable for wiring convenience
  • Accepts 12 to 22 gauge wires
  • Positive latching feature for connection
    integrity

21
Loaded With Standard Hardware Features
  • 3 universal analog inputs (2 3 optional on
    F4S)
  • TC, RTD, process (no DIP switches)
  • 4 digital inputs (standard)
  • Eight digital outputs (standard)
  • Programmable events
  • Chamber heat cool control functions

22
Modular Hardware Inputs and Outputs
  • Field replaceable input and output modules
  • Dual control outputs
  • Heat or cool or Off
  • Linear or time proportioned
  • Switched dc/open collector, SSR, process
  • Alarms (2 standard)
  • Process or deviation
  • 2 A mechanical relays

23
Leading the Way in Communications
  • Serial communications standard
  • EIA 232 EIA 485 hardware interfaces
  • MODBUS protocol
  • 9600 and 19,200 baud
  • Allows controller software updates in field

24
Hardware Features
  • Retransmit outputs
  • 2 optional
  • Current or voltage
  • Process, set points, power
  • Universal power supply
  • 85 to 265 vac/vdc, 50 to 60 Hz
  • Optional 24 to 28 vac/vdc

25
Performance Specifications
  • Operating range
  • 0 to 55 C
  • Calibration accuracy
  • 0.1 of span, /- LSD (whole digit)
  • Sensor update rate
  • 20 Hz, 50 milliseconds, channel 1

26
F4 Hardware Architecture
Input to Output Isolation Minimum 500
Vac/Vdc between blocks
27
Agency Approvals
  • UL, c-UL 916 listed
  • User replaceable input and output modules
  • European CE conformity
  • EN 50082-2, immunity standard
  • EN 50081-2, emission standard
  • EN 61010-1 low-voltage directive, safety
  • NEMA 4X, IP 65 front panel seal

28
Accurate Timing of Profiles
  • Real time clock
  • /- 92 seconds/month
  • Lithium battery
  • 7 year shelf life

29
Software Architecture
Main Page
Operations Page
Profile Page
Setup Page
Factory Page
30
Software Architecture
  • Guided setup programming
  • Guided configuration
  • Presents a sequence of parameter choices needed
    to complete a functional configuration
  • Full unabbreviated text
  • Uses full text messages, not cryptic parameter
    and configuration names

31
Software Architecture
  • Context sensitive help

Toggle the Information key
32
Programming An Autostart Step
Set F4 Controller to Start Profile at 430 AM on
Monday
33
Programming An Autostart Step
34
Programming An Autostart Step
35
Programming An Autostart Step
36
Programming An Autostart Step
37
Programming An Autostart Step
38
Programming An Autostart Step
39
Programming An Autostart Step
Use i Key for More Information
40
Programming An Autostart Step
41
Programming An Autostart Step
Save Change, Autostart Setup Complete
42
F4 Software Architecture
  • Function Naming
  • Optional, up to 10 Characters
  • Better operator recognition

Enter Alarm Name Alarm 1 Adjusts
Character Selects Character
43
F4 Software Architecture
  • Pop Up Displays
  • Lets the user know when the F4 software is
    storing changes in Non Volatile Memory

Save Setup Changes or restore Values?
Restore Save
44
F4 Main Page
Main Page____ Go to Operations Go to Setup Go to
Factory
Main Page
  • Display key control parameters
  • Up to 16 customer programmable control parameters
  • Set points, alarms, errors, power
  • Profile operational information
  • Inner loop set point (cascade control)
  • Gateway to controller configuration

45
F4 Operations Page
Main Page____ gtGo to Operations Go to Setup Go to
Factory
Operations Page
  • Auto tune PID control parameter values
  • Edit PID
  • Alarm set points

46
F4 Profiles Page
Main Page____ Go to Operations gtGo to Profiles Go
to Setup
Profile Page
  • Create profiles
  • Edit profiles
  • Delete profiles
  • Rename profiles
  • Embedded Mil-Std 810

47
F4 Set Up Page
Setup Page
Main Page____ Go to Operations gtGo to Setup Go to
Factory
  • System Settings
  • GSD, Clock, PID Units, F or C, Auto Tune SP,
    Sensor Failure, Open Loop, Power Out Action
  • Inputs Analog and Digital
  • Outputs Control, Digital, Alarm, Comms, Retrans
  • Custom main page Selections

48
F4 Factory Page
Main Page____ Go to Operations Go to Setup gtGo to
Factory
Factory Page
  • Set Lockout
  • Change password
  • Diagnostics
  • Date code, software revisions, diagnostic tests
  • Calibration data

49
F4 Profile Operation
  • Up to 40 flexible length profiles
  • Optional naming
  • 256 total steps (segments)
  • Six step types
  • Ramp Time/ Rate (single channel only) Soak,
    Auto Start, Jump, End

50
F4 Profile Operation
  • Wait For feature
  • Programmable in ramp/soak type steps
  • Digital inputs configured as wait for events
  • Named choices are displayed
  • Analog inputs (1 - 3)
  • Step time starts when Wait For is met

51
F4 Profile Operation
  • Event output feature
  • Programmable in ramp/soak type steps
  • Digital outputs configured as events
  • Named choices are displayed
  • Manually adjustable
  • Static set point mode or while profile is on hold
  • As a selection for the main page

52
F4 Profile Operation
  • Guaranteed Soak feature
  • Programmable in ramp/soak type steps
  • Guaranteed soak band set in the system menu
  • Profile time pauses when process value goes
    outside of the soak band

53
F4 Profile Operation
  • Power outage recovery feature
  • Programmable in the system menu
  • Power outage time
  • Power outage action
  • Continue profile
  • Hold profile
  • Terminate profile
  • Reset profile
  • Go to idle set point (maintain event outputs)

54
F4 Ramping Control Operation
  • Heat and cool PID
  • 5 PID sets per channel
  • Profile step selectable
  • Cascade operation
  • Channel 1
  • Process or Deviation
  • Input 1 Inner Loop
  • Input 3 Outer Loop

55
F4 Ramping Control Operation
  • Channel 2 humidity control
  • Vaisala Rotronic non-temperature compensated
  • Wet /Dry bulb control
  • Any sensor type
  • Rotating process displays
  • Set up menu choice
  • Alternately display any or all of the three
  • Analog input process values

56
F4 Digital Input Operation
  • Four digital inputs
  • Programmable wait for events
  • Namable
  • Front panel lockout
  • Reset alarms
  • Turn outputs OFF
  • Start, pause or terminate a profile

57
F4 Digital Output Operation
  • Eight Digital Outputs
  • Programmable as event outputs, namable
  • Manual or profile selectable
  • Optional Function DO5 Complementary Output
  • Optional Function DO6 Boost Heat
  • Optional Function DO7 Boost Cool
  • Optional Function DO8 Compressor Control

58
F4 Digital Output Operation
  • Digital Output 5 Selection
  • Complementary output
  • Operates in conjunction with Channel 1
  • Control outputs
  • Selectable to complement time proportioned
    outputs only
  • Output 1A ON/CLOSED
  • DO5 OFF

59
F4 Digital Output Operation
  • Digital Output 6 Selection Boost Heat
  • On/Off control of auxiliary heat source
  • Operates based on Channel 1 percent power demand
  • Boost heat power level
  • Power level at which boost delay time starts
  • 5 hysteresis
  • Boost delay
  • Minimum time that the boost power level is
    exceeded before boost is enabled

60
F4 Digital Output Operation
Digital Output 6 Boost Heat
100
Boost Percent Power 85
85
Heat Power
0
Time in Seconds
Boost Delay Time 30 Seconds
On Off
Boost Heater
61
F4 Digital Output Operation
  • Digital Output 7 Selection Boost Cool
  • On/Off control of auxiliary cool source
  • Operates based on Channel 1 power demand
  • Boost cool power level
  • Power level at which boost delay time starts
  • 5 hysteresis
  • Boost delay
  • Minimum time that the boost power level is
    exceeded before boost is enabled

62
F4 Digital Output Operation
  • Digital Output 8 Selection Compressor
  • On/Off control of refrigerant compressor
  • Operates based on Channel 1 percent power demand
  • Compressor ON/Off percent power level 100 to
    -100
  • Compressor OFF delay in seconds
  • Cool power demand no longer exceeded for this
    time delay
  • Compressor ON delay
  • Delay in seconds before compressor will restart

63
F4 Digital Output Operation
Compressor off Power 2
Digital Output 8
100
Compressor on Power 0
2
0
Time in Seconds
- 100
Power
Compressor On Delay 45 Seconds
On Off
Compressor off Delay 20 Seconds
Compressor
64
F4 Ramping Control Operation
Main Page
  • Additional displayable functions when running a
    profile
  • Current file, current step, step type
  • Channel target set points, step time remaining
  • Wait for status, event output status, event input
    status
  • Last jump step, jump count
  • 16 displayable parameters total

65
Creating a Part Number - F4S
Single Channel Ramping Controller
F4S X - X X X A - X X X X
Power Supply
RG Displays Custom Options
Output 1A
Language Option
Output 1B
English, German Spanish, French
Auxiliary Input
Auxiliary Retransmit
66
Creating a Part Number - F4D
Dual Channel Ramping Controller
F4D X - X X X A - X X X X
Power Supply
RG Displays Custom Options
Output 1A
Language Option
Output 1B
English, German Spanish, French
Output 2A
Output 2B
Auxiliary Retransmit
67
F4S and F4D Feature Summary
  • F4S single channel
  • Single channel PID controller
  • 1 universal analog input
  • 4 digital event inputs
  • EIA232/485 comms
  • 8 digital event outputs
  • 2 alarm outputs
  • 40 files, 256 steps
  • F4D dual channel
  • Dual channel PID controller
  • 3 universal analog inputs
  • 4 digital event inputs
  • EIA232/485 comms
  • 8 digital event outputs
  • 2 alarm outputs
  • 40 files, 256 steps

68
Reasons to Buy
  • Usability
  • High definition display
  • Information key
  • Guided set up and programming

69
Reasons to Buy
  • Reliability
  • ISO 9001 manufacturing
  • Three year warranty
  • Year 2000 compliant

70
Reasons to Buy
  • Performance
  • Control accuracy
  • Extensive feature set
  • Exhaustive life qualification testing
  • Availability
  • 4 day lead-time

71
Reasons to Buy
  • Support
  • Local sales specialists
  • Applications engineering support
  • Rapid field returns department

72
Series F4S and F4D 1/4 DIN Ramping Controllers
Write a Comment
User Comments (0)