PQSL Talk

1 / 14
About This Presentation
Title:

PQSL Talk

Description:

Nowadays, most sites are controlled in potential by lease and/or OZP. Backgrounds/ Main points ... PNAP 236 - Design of Car Parks and Loading/ Unloading Facilities ... – PowerPoint PPT presentation

Number of Views:44
Avg rating:3.0/5.0
Slides: 15
Provided by: bui57

less

Transcript and Presenter's Notes

Title: PQSL Talk


1
PQSL Talk
  • Site Classifications
  • GFA Exemption
  • In the context of current practice
    interpretation under the Buildings Ordinance,
    mainly based on B(P)R enacted on 1.6.1956

2
Site Classifications
  • Definition under the Buildings Ordinance
  • Backgrounds/ main points
  • Discussion (more interactive)

GFA Exemptions
  • Definition under the Buildings Ordinance
  • Backgrounds/ main points
  • Discussion (more interactive)

3
Site Classifications
  • Definition
  • Interpretation under B(P)R 2
  • Site/Adjoining sites/ lots
  • Backgrounds/ Main points
  • Abutting a street (4.5m)
  • Intensity g Serviceability Accessibility
  • g Health Safety
  • Class A, B, C g4.5m street / 40 / 60
  • How many site classifications ?

4
Site Classification
Site Classification
Class A site
Class B site
5
Site Classification
Site Classification
6
Site Classification
Site Classification
  • Discussions
  • B(P)R 19(1)gA, B, C
  • B(P)R 19(2)g non A, non B, non C (i.e. the 4th
    type)
  • B(P)R 5(1)g proper access from a street
  • B(P)R 5(2)g provide access lane/ road
  • PNAP 263 Street for Site Classification
  • PNAP 118 Streets in relation to Site Area-
    B(P)R 23(2)(a)

7
GFA - Exemptions
  • Definition Gross Floor Area
  • B(P)R 2 external wall floor etc
  • B(P)R 23(1) Building height
  • B(P)R 23(2) Site Area
  • B(P)R 23(3)(a)
  • GFA shall be the area contained .. within
    external walls each floor level including
    floor below the level of the ground) balcony ..
    the thickness of external walls.

8
GFA Exemptions
  • Definition Gross Floor Area
  • B(P)R 23(3)(b)
  • may disregard parkingloading or unloading,
    material recovery chambers refuse storage
    other facilities provided to the satisfaction
    of the Building Authority TBE machinery or
    equipment lift, air-conditioning similar
    services.
  • B(P)R 23A Genuine Hotel
  • Non-domestic P.R. S.C.
  • Consisting some supporting facilities (i.e. BOH
    areas)

9
GFA Exemptions
  • Backgrounds/ Main points
  • Control the building bulk g Health Safety
  • Previously mainly controlled by volume of a
    building, now by GFA in term of P.R S.C., and
    others
  • Nowadays, most sites are controlled in potential
    by lease and/or OZP
  • Still, you can see GFA is being somehow used to
    determine some safety standards (like MOE
    provisions) under the Buildings Ordinance. (e.g.
    230m2 in Fire Safety (Commercial Premises)
    Ordinance)

10
GFA Exemptions
  • Backgrounds/ Main points
  • More direct control by Fire Safety Codes (MOE,
    MOA, FRC etc)
    GFA g indirect control g Safety/ Health g
    seems fading out
  • However, values of GFA still exist, like what?
  • P.R. S.C. to be determined by BA on B(P)R 19(2)
    cases, e.g. existing bulk
  • Rating Valuation
  • Implication on lease/ OZP

11
Discussions
  • Exemptions on GFA calculations
  • Why BA could discount some items from GFA?
  • What to consider?
  • What items would normally be accepted for GFA
    exemption ?

?
12
Other Relevant PNAPs
  • PNAP 13 - Calculation of Gross Floor Area
    and Non-Accountable Gross Floor Area -
    Building (Planning) Regulation 23(3)(a) and
    (b)
  • PNAP 68 - Projections in relation to Site
    Coverage and Plot Ratio - Building
    (Planning) Regulations 20 and 21
  • PNAP 111 - Hotel Development
  • PNAP 116 - Amenity Features

13
Other Relevant PNAPs
  • PNAP 207 - Provision of Better Lift Service
  • PNAP 236 - Design of Car Parks and Loading/
    Unloading Facilities
  • PNAP 258 - Provision of Sky Garden in Refuge
    Floor
  • JPN 1 - Green and Innovative Buildings
  • JPN 2 - Second Package of Incentives to
    Promote Green and Innovative Buildings

14
  • Thank You
  • And Take Good Care of you
  • all you love
Write a Comment
User Comments (0)