Title: Simulations and Virtual Laboratories in Chemistry Education


1
Simulations and Virtual Laboratories in
Chemistry Education Jetse Reijenga Eindhoven
University of Technology, the Netherlands
  • Summary
  • Chemistry education is particularly expensive
    because of the need for advanced laboratories
    with complicated equipment, chemicals and safety
    precautions. Naturally, these facilities are
    often shared with research staff, but that
    doesnt make it any easier accommodating tens of
    students or more, performing identical
    experiments in a limited time frame. Experiments
    in education however are essential. During the
    past decades, we have been able to show 1 that
    experiment simulations and even virtual
    laboratories can provide a valuable addition to
    the experimental part of the study. Several
    examples in the field of analytical
    instrumentation (chromatography and
    electrophoresis) will be illustrated.
  • Introduction
  • When embedding simulations in a curriculum, we
    suggest following approach
  • Theoretical basics are taught in lectures and
    self-study format. Most simulators can generate
    useful illustration material and demos.
  • Students then perform a few simple introductory
    experiments on preset equipment, largely to
    illustrate the order of magnitude of samples
    handled, of the time needed to carry out the
    experiment, and to appreciate the complexity of
    expensive equipment.
  • Finally, students are given simulation
    assignments, e.g. systematically changing one or
    more parameters, and drawing conclusions from the
    results. An advanced assignment might involve
    optimizing a difficult separation, using several
    parameters.
  • Results and Discussion
  • The default screen layout of simulators for
    analytical separation instruments consist most
    often of a menu and a chromatogram (detector
    signal vs. time) as depicted in the figures
    below.

Simulation programs for capillary electrophoresis
are also available. HPCESIM was published in 1994
6. Options for illustrating chiral separation
were added in 1997. The program plots of
selectivity vs pH for easy method development and
offers possibility to study the effects of
temperature on efficiency.
More recently, a sophisticated windows version
(Peakmaster) was published by Bohuslav Gas of
Prague University 7. This one is very
user-friendly and has a huge easily editable
sample data base. Complications such as ghost
peaks, occurring when using certain background
electrolytes, are also featured.
Whereas all of the aforementioned simulators
generated detector signals after separation,
dynamic simulators such as SIMUL 7 generate
concentration profiles in the separation chamber
at small time intervals. We can thus monitor on a
micrometer scale how separations develop locally.
Valuable insights for advanced users!
On the left, the output of a gas chromatography
simulator 2, n-alkanes in a linear gradient on
a non-polar capillary column. The simulator has 2
stationary phases, 2 detectors and 5 carrier
gasses, enabling in finite number of hypothetical
separations. The program features many other
output screens, e.g. van Deemter plots and
detailed plate height info.
  • Virtual Laboratory
  • Obvious synergy can be achieved by combining
    simulators of different instruments in solving a
    hypothetical analysis problem. A very
    sophisticated integration of numerous techniques
    is ProteinLab 8 by A.G. Booth of Leeds
    University. It is a simulator dedicated to
    isolate and identify a protein from a mixture of
    20, and features the following techniques
  • Heat treatment
  • Ammonium sulphate precipitation
  • Gel filtration
  • Ion-exchange chromatography
  • Hydrophobic interaction chromatography
  • Isoelectric focusing
  • Affinity chromatography
  • HPLC
  • SDS-PAGE
  • Two-dimensional electrophoresis

On the right, the output of a HPLC simulator
3, a mixture in a reversed phase water-methanol
gradient also shown are curved solvent viscosity
and pressure drop traces (maximum for
water/methanol). This simulator has 2 solvent
modifiers, 2 detectors (including diode array)
and 6 column types (among which a
state-of-the-art monolith column).
This is a simulator for Permeation Chromatography
simulator 4 for SEC of polymers. It includes 21
different polymers, 12 types of columns and 5
detectors, including novel Charged Aerosol. The
example on the screen illustrates the need for
using universal calibration with K and a values
from the Kuhn-Mark-Houwink-Sakurada viscosity law.
  • Conclusions
  • Prior basic knowledge of techniques still
    required as the programs are not self-contained
    tutorials, but the programs can also be used in
    classroom demonstrations, and to generate example
    illustrations for textbooks. I even used
    ProteinLabs once in an exam setting. Valuable
    insight into theory and an enormous time-gain can
    be obtained in organizing dry-lab practicals.
  • Powerful instrument simulators are available for
    all analytical separation techniques. All
    examples mentioned are available as free
    download, or can be obtained from the author on
    request. Why not give it a try?!
  • References
  • http//edu.chem.tue.nl/ce
  • J.C. Reijenga, J. Chromatogr., 1991, 588, 217-224
  • J.C. Reijenga, J. Chromatogr. A, 2000, 903, 47-54
  • J.C. Reijenga, W.J. Kingma, D. Berek, M. Hutta,
    Acta Chim. Slov. 2007, 54, 79-87
  • J.C. Reijenga and M. Hutta, J. Chromatogr. A,
    1995, 709, 21-29
  • J.C. Reijenga and E. Kenndler, J. Chromatogr. A,
    1994, 659, 403-415 and 417-426.
  • http//www.natur.cuni.cz/gas/
  • http//home.btconnect.com/agbooth/archive/

Another technique, combining chromatographic and
electrophoretic principles, is called micellar
electro-kinetic capillary chromatography 5. The
(un)charged sample components migrate within a
time window (between t0 and tm), in increased
order of hydrophobicity (in sequence reversed
from RP-HPLC). In the example given, the whole
range of retention factors from zero to infinity
is shown.
j.c.reijenga_at_tue.nl - 20th ICCE Mauritius 2008