Boiler Room - 15 to 20 ppm. Kindergarten/1st Grade Hall - 4 ppm. Teachers Lounge - 2 ppm ... Boiler Room - 1690 ppm. Outdoors - 401 ppm. Other Safety Issues ... – PowerPoint PPT presentation

Number of Views:155
Avg rating:3.0/5.0
Slides: 12
Provided by: Ild6
Category:

less

Transcript and Presenter's Notes

Title: INDOOR AIR QUALITY CASE STUDY CONDUCTED BY: ILLINOIS ONSITE SAFETY AND HEALTH CONSULTATION PROGRAM


1
INDOOR AIR QUALITY CASE STUDYCONDUCTED
BYILLINOIS ON-SITE SAFETY AND HEALTH
CONSULTATION PROGRAM
2
Background Information
  • Student With Respiratory Problems
  • Parent Called Private Environmental Consultant
  • Parent Was Referred To On-Site Consultation
    Program
  • School Principal Requested Our Assistance

3
School Description
  • Catholic Grade School
  • Preschool to 6th Grade
  • (Approx. 350 Students)
  • Configuration
  • Original L Section
  • Two New Add On Wings
  • Square Central Courtyard

4
Air Sampling
  • Mold / Fungal Spores
  • - Visual ID of Spores
  • - Colony Forming Units
  • Carbon Monoxide
  • Carbon Dioxide
  • Temperature
  • Relative Humidity

5
Findings Temperature and Relative Humidity
  • ANSI/ASHRAE 55 Recommending Limits
  • Winter 68 to 74.5 Degrees F.
  • Summer 73 to 79 Degrees F.
  • Relative Humidity 30 to 70
  • The school was within recommended limits.

6
FindingsMold and Fungal Spores
  • Highest to Lowest Areas
  • 1. Outdoors in Courtyard
  • 2. Boiler Room
  • 3. Janitors Closet
  • 4. Kitchen
  • 5. First Grade - Window open to
  • courtyard

7
FindingsCarbon Monoxide
  • Limits
  • OSHA 50 Parts Per Million (PPM)
  • ACGIH TLV 25 PPM (Recommended)
  • Highest to Lowest
  • Boiler Room - 15 to 20 ppm
  • Kindergarten/1st Grade Hall - 4 ppm
  • Teachers Lounge - 2 ppm
  • Outdoors - 1 ppm

8
FindingsCarbon Dioxide
  • Limits OSHA 5000 ppm
  • ACGIH TLV 5000 ppm
  • ANSI/ASHRAE 1000 ppm (Recommended)
  • Highest to Lowest
  • Classrooms - 2160 to 3030 ppm
  • Teachers Lounge - 1911 ppm
  • Boiler Room - 1690 ppm
  • Outdoors - 401 ppm

9
Other Safety Issues Addressed
  • Bloodborne Pathogens
  • Hazard Communications Program
  • Evacuation Route
  • Workplace Hazard Assessment PPE Use
  • Fire Extinguishers not annually inspected
  • OSHA Poster

10
Feedback From Principal
  • I really appreciate all that you did for our
  • school last year. It helped us a lot. When the
  • State came through to conduct their
  • inspection, they were blown away with all
  • the work that was done in the area of health
  • and safety. Thanks to you.

11
Don WilliamsDepartment of Commerce and Community
Affairs200 S. Wyman St. Suite 102Rockford, IL
61101Tele. (815) 987-7663dwilliam_at_commerce.stat
e.il.us
Write a Comment
User Comments (0)
About PowerShow.com