Title: FPD Calibration Studies


1
FPD Calibration Studies
  • Michael Strang
  • University of Texas at Arlington

2
First Appearance of Problem
  • This is a recent calibration with 0x400 gain on
    board. Notice the dropping of the mean at the
    edge of SIFT chips happening on two boards in
    different cassettes

3
Old data looking for problem
  • This is an old calibration (around April) with
    0x400 gain on board. The evidence of this
    structure is not as clear if it is present at all.

4
Trying to isolate problem
  • During recent access last week, we unplugged the
    bayonet, unplugged the cables from the tunnel
    going to the TPP and isolated the TPP from
    contact with anything else (flex cables still
    connected) and structure is very clear.

5
Looked at CFT boards as well
  • For comparison, looked at a random board from a
    different crate (53). Surprisingly, this same
    structure is present in parts of the board so
    while this problem seems enhanced in the FPD
    boards, it appears to be present in other boards
    as well.