Cristopia (CIAT) - energy savings systems in air
conditioning
3
CRISTOPIAEnergy Systems
  • Developed an original energy storage system in
    1982
  • Became a subsidary of CIAT in January 1988
  • LOCATION
  • Head office factory in Vence (French Riviera)
  • French Commercial Office located near Paris
  • Asian Office in Kuala Lumpur (Malaysia)
  • WORLD-WIDE REPRESENTATION
  • Distributors of CRISTOPIA technology in more than
    25 countries
  • LICENCE AGREEMENTS
  • in Japan Mitsubishi Corporation
  • in South Korea D.I. Corporation
  • in India Cristopia Energy Systems India Private
    Ltd. (Joint Venture)
  • in China Hangzhou CIAT Refrigeration Equipments
    Co. Ltd
  • More than 500 references in 25 countries
  • 2.5 millions of kWh daily shifted

4
BASICS OFTHERMAL ENERGY STORAGE
5
WHY STORE ENERGY ?
  • to size a chiller to satisfy the average load
    instead of the maximum load (few hours per day or
    even per year)
  • the chiller runs on a continuous basis
  • to increase plant capacity
  • to increase system reliability (back-up)
  • to increase system efficiency (no short cycle)
  • to protect the environment
  • reduce CO2 emissions
  • limit the use of CFC's or HCFC's
  • for energy management (off-peak electricity
    period)
  • to reduce system operating costs

6
TRADITIONAL SOLUTION
STL SOLUTION Reduced Installed Capacity
7
Energy managementbyCRISTOPIA Thermal Energy
Storage
  • Reduce
  • chiller size by 30 to 70
  • use of refrigerant by 50 to 80
  • cooling tower installation
  • space for plant
  • maintenance
  • running cost
  • CO2 emissions
  • Increase
  • cooling capacity from existing chiller
  • plant utilization
  • equipment life
  • Additional benefits
  • avail yourself to a back-up system
  • shift cooling load from peak hours to off-peak
    period

8
AIR CONDITIONING
APPLICATIONFIELDS
  • Office buildings
  • Hotels
  • Hospitals
  • Banks
  • Conference centres
  • Computer rooms
  • Airports
  • Clean rooms
  • Supermarkets
  • Sports centres
  • Theatres, cinemas, TV studios

9
INDUSTRIAL PROCESS COOLING
APPLICATIONFIELDS
  • Dairy and food industries
  • Bottling plants
  • Slaughter houses
  • Meat industries
  • Cold storage
  • Central kitchens
  • Breweries
  • Laboratories
  • Pharmaceutical industries
  • Chemical plants
  • Refineries
  • Computing rooms

10
CRISTOPIALATENT HEAT STORAGESTL
  • FOR
  • AIR CONDITIONING
  • INDUSTRIAL APPLICATIONS
  • For a better management and
  • use of electricity

11
STL SYSTEM
  • 2 elements
  • tank
  • (made to measure according to site requirement)
  • nodules

12
THE NODULE
  • Polyolefines material chemically neutral
    towards eutectics and heat transfer fluid
  • Controlled thickness no migration of the heat
    transfer fluid
  • Cap ultrasonically welded
  • External diameter 77 78 mm .. Industrial
    cooling
  • 98 mm ... Air Conditioning
  • Heat exchange surface
  • 77 78 mm .... 1 m2/kWh stored
  • 98 mm ... 0.8 m2/kWh stored
  • Useful number of nodules per m3
  • 77 mm ... appr. 2 548
  • 78 mm ... appr. 2 444
  • 98 mm ... appr. 1 222

13
TESTS of the PRODUCT
  • CEA
  • PCM ageing
  • ECOLE des MINES de PARIS Nodule mechanical
    strength
  • CETIAT
  • STL thermal performances
  • COSTIC
  • STL thermal performances
  • CSTB
  • STL durability

14
CHARGE MODE
OPERATING PRINCIPLES
15
DISCHARGE MODEPartial Storage
OPERATING PRINCIPLES
16
ADVANTAGES of the STL
  • Reliable system manufactured automatically with a
    high level quality control
  • Storage temperatures adapted to usage (from
  • -33C to 27C)
  • Static system
  • maximum reliability
  • no risk of breakdown
  • no maintenance
  • Closed system with high service pressures allowed
  • Adaptability to site
  • Optimized time to store due to a high exchange
    surface
  • High cooling capacity
  • Eco-friendly system
  • Large know-how based on more than 16 years of
    experience
  • More than 500 references worldwide

17
CRISTOPIA Energy Systems
Airport, bank, hospital, office building,
department store, central kitchen, computer
room, food industry, dairy industry,...
18
(No Transcript)
19
CONCLUSION
  • Technical
  • reduction of installed chiller capacity
  • reduction of short-cycling
  • increase in system efficiency and reliability
  • simplified maintenance
  • flexible system
  • Environmental
  • limitation of the use of CFC's or HCFC's
  • reduction of CO2 emissions
  • saving of up to 15 of energy due to a better
    energy management
  • Financial
  • shifting of kWh from day to night
  • saving on the maximum demand charges
  • energy saving

20