Title: Large%20sample%20dose%20content%20uniformity%20test:%20parametric%20and%20nonparametric%20(counting)
1Large sample dose content uniformity test
parametric and nonparametric (counting)
- Meiyu Shen, PhD
- Collaborators Xiaoyu Dong, Ph.D., Yi Tsong, PhD
- Office of Biostatistics, CDER, FDA
- This presentation contains opinions of the
authors that do not represent the official
position of U.S. Food and Drug Administration
2Outline
- Purpose of uniformity of dosage unit
- Harmonized USP dose content uniformity test with
a small sample - Large n dose content uniformity test
- EU methods
- Option 1 Parametric method
- Option 2 Nonparametric method (Counting method)
- Two one-sided tolerance interval method
- Comparison between the EU method and the two
one-sided tolerance interval method - Conclusion
3Uniformity of dosage unit
- The purpose of uniformity of dosage unit
- The degree of uniformity in the amount of the
drug substance among dosage units. -
- Demonstrated by one of the follows
- Dose content uniformity (focus here)
- based on the assay of the individual content of
drug substance(s) in a number of dosage units - Weight variation
4Indifferent zone
5Harmonized USP DCU for small n
Step 1, 10 tablets
Step 2, additional 20 tablets
No
Yes
Fail
Yes
Pass
Pass
6EU option 1 for large n100
Take n tablets, Xi, i1,2,,n
No
Fail
Yes
6
Pass
7EU option 2 for large n100
Take n tablets, Xi, i1,2,,n
No
Fail
Yes
Pass
7
8EU Option 2 acceptable number of individual units
c1 outside (10.15) and c2 outsides (10.25)
n c1 c2
100 3 0
123 3 0
150 3 0
176 5 1
196 6 1
.
9PTIT_matchUSP90
Take n tablets, Xi, i1,2,,n
No
Fail
Yes
Pass
9
10EU option 1 and PTIT_matchUSP90
- Two-sided tolerance interval
- Control probability within (85,115)
- Two-sided hypothesis
- Two one-sided tolerance interval
- Control probability each tail outside (85,115)
- Two one-sided hypothesis
P
(1-P)/2
11EU option 1 and PTIT_matchUSP90
- Formula for K
-
- Confidence level 1-a0.95
- Each tail probability (1-p(n))/2
- For n30, p82.04,
- Formula for K
-
- Confidence level
- Center Coverage
12K values of EU Option 1 and PTIT_matchUSP90
Sample size PTIT_matchUSP90 EU Option 1
100 2.0475 2.15
1000 2.2321 2.27
13Normal on target product, mean100
14Normal off target product, mean102
15Mixed normal on target overall mean
16Mixed normal off target overall mean
17Bias of EU Option 1
18Special distribution
- Assume the individual tablet dose content is
distributed as a uniform distribution in the
range from 85 to 115 with 97 probability and a
value 84 with 3 probability. - The probability of passing USP harmonized DCU is
3.72 for a sample size of 30 tablets. - Comparison of EU Option 2 and PTIT_matchUSP90 in
next table - EU Option 2 has 45.5 probability to pass the DCU
test when n300. - the PTIT_macthUSP90 has zero passing probability
for n100.
19EU Option 2 and PTIT_matchUSP90
Xi a uniform distribution in the range from 85
to 115 with 97 probability and a value 84 with
3 probability
Sample size, n Acceptance probability Acceptance probability
Sample size, n EU option 2 PTIT_USPmatch90
100 0.6458 0
150 0.5276 0
200 0.6047 0
300 0.455 0
500 0.3509 0
1000 0.2075 0
20EU Option 2 and PTIT_matchUSP90for 2 special
cases
Case Sample size, n Passing probability Passing probability
Case Sample size, n EU Option 2 PTIT_matchUSP90
Xi is 100 with 97 probability, and 50 with 3 probability. 100 0.641 0.196
Xi is 100 with 97 probability, and 50 with 3 probability. 150 0.523 0.172
Xi is 90 with 97 probability, and 50 with 3 probability. 100 0.648 0.045
Xi is 90 with 97 probability, and 50 with 3 probability. 150 0.530 0.012
21Conclusion
- A large difference in acceptance probability
between EU option 1 and PTIT_matchUSP90 when the
batch mean is off-target. - Larger passing probability for EU Option 1 than
PTIT_matchUSP90 - No much difference in acceptance probability
between EU option 1 and PTIT_matchUSP90 when the
batch mean is on-target. - Bias of EU Option 1
- EU Option 1 has higher probability of passing the
off-target product than that of passing the
on-target mean product for a given coverage
within (85, 115)
22Conclusion (continued)
- EU Option 2
- Issue with a large variability for a mixture of
97 probability of distributing uniformly with
(85, 115) and 3 probability of being 84)
using a sample of 200 - 60 probability to pass EU Option 2
- 0 probability to pass PTIT_matchUSP90
- 3 probability to pass USP harmonized
- Issue with a location shift of the mean product
- The same probability to pass the EU Option 2 for
97 population with 100 content and 97
population with 90 content. - Off target product 97 population with 90
content using a sample of 150. - gt50 probability to pass the EU Option 2
- About 1 probability to pass PTIT_matchUSP90
23References
- USP Pharmacopoeia 2015
- European Pharmacopoeia 7.7
- European Pharmacopoeia 8.1
- Meiyu Shen, Yi Tsong, Xiaoyu Dong, Statistical
Properties of Large Sample Tests for Dose Content
Uniformity, Therapeutic Innovation Regulatory
Science, 2014, Vol. 48(5) 613-622 - Meiyu Shen and Yi Tsong, Bias Of The United
States Pharmacopeia Harmonized Test For Dose
Content Uniformity, United States Pharmacopeia
forum, January 2011
24Thank you!