Liquid Leak Detection/Location Systems for piping, raised floors, semiconductor tools, containment piping, fuel systems and other applications - PowerPoint PPT Presentation

About This Presentation
Title:

Liquid Leak Detection/Location Systems for piping, raised floors, semiconductor tools, containment piping, fuel systems and other applications

Description:

Liquid Leak Detection/Location Systems for piping, raised floors, semiconductor tools, containment piping, fuel systems and other applications – PowerPoint PPT presentation

Number of Views:804
Avg rating:3.0/5.0
Slides: 28
Provided by: ArtGi7
Category:

less

Transcript and Presenter's Notes

Title: Liquid Leak Detection/Location Systems for piping, raised floors, semiconductor tools, containment piping, fuel systems and other applications


1
  • Liquid Leak Detection/Location Systems for
    piping, raised floors, semiconductor tools,
    containment piping, fuel systems and other
    applications

2
Company Profile
  • PermAlert is part of Perma-Pipe the largest
    prefabricated preinsulated pipe manufacturer in
    the US
  • PAL-AT Leak Detection was introduced in 1988 and
    was the reason for founding PermAlert ESP
  • Sales Volume of the parent corporation (MFRI) is
    about US 178 million with over 500 employees
    worldwide

3
Art Giesler
  • Mechanical Engineer from UMR
  • Worked for York Air Conditioning
  • MBA from TCU
  • Hydro-Air, Inc. a manufacturers rep
  • PermAlert ESP
  • Projects Social Security, VISA, IBM, Intel,
    AMD, HP, Exodus, Digital Island, US West, Nuclear
    Power Plants, DOE

4
PAL-AT Cable Systems and LiquidWatch Probe
Systems
  • PAL-AT uses coaxial cables and probes to monitor
    for liquid leakage. The system can detect and
    locate leaks, breaks and shorts on the sensor
    cable as well as probe activations.
  • LiquidWatch is a probe monitoring system and can
    monitor up to 64 probes from a single panel. The
    probes are monitored for activation, breaks and
    shorts.

5
Time Domain ReflectometryPAL-AT
  • TDR is a cable measuring technology related to
    sonar and radar. By sending energy pulses down
    the center conductor of a coaxial cable and
    measuring the reflected energy to the outer braid
    a map can be stored of the cable and monitored
    for change. When change occurs the type of alarm
    and its location is displayed on the panel.

6
TDR Trace of Dry Cable
7
TDR Trace with Leak Detected
8
TDR Trace of System with Wet Cable
9
TDR Trace showing Growing Leak
10
Map 3 Response
11
Second Leak Detected
12
Monitoring with Liquid on the Cable
13
Break Detected
14
Short Detected
15
Probe Activated
16
PAL-AT Panels
  • AT20C - Monitoring up to 2,000 (600 m) on a
    single cable
  • AT50C - Monitoring up to 5,000 (1500 m)
    equivalent length on a single cable
  • AT20K - Monitoring up to 7,500 (2500 m)
    equivalent length per cable with a maximum of two
    cables
  • AT40K - Monitoring up to 5,000 (1500m)
    equivalent length per cable with a maximum of
    eight cables
  • AT80K - Monitoring up to 7,500 (2500 m)
    equivalent length per cable with a maximum of
    eight cables

17
Types of CablePAL-AT
  • AGW Gold Sensor cable for use in containment
    piping, trenches, trays
  • and subfloors
  • AGT Gold Sensor cable for use
    in subfloors and trays. More
    sensitive than AGW
  • TFH Sensor cable for detecting hydrocarbons
    and solvents while ignoring water TFH
  • TFH

18
Types of ProbesPAL-AT and LiquidWatch
  • PHL/PWS Solid state probes for hydrocarbon and
    conductive liquids
  • PSTV/PTHL/PFS Float switches for high/low level
  • PT10 (PAL-AT) Probe integrators and PA-10
    (LiquidWatch) Probe Adaptors for dry contacts

19
LiquidWatch
  • LiquidWatch has two basic panels. The LW64 is
    for use in normal classified probe locations
    while the LW64IS provides a UL Listed System for
    monitoring in Class 1, Division 1 Groups C D
    locations. The basic panel monitors up to eight
    probes with modules being added for additional
    probe requirements.

20
Applications
  • Raised Floors - Data Centers, ISPs, Clean Rooms
    Telecommunication, Semiconductor, Office Bldgs
    Pharmaceutical
  • Piping - Containment piping, single wall piping,
    hydrocarbon piping, waste drains
  • Trenches and Trays - Under wet benches, piping
    and equipment
  • Generators, Electrical Switch Gear and
    Transformers for hydrocarbon leakage or water
    seepage
  • What ever needs liquid leakage detection that a
    probe or sensor cable can be used

21
(No Transcript)
22
(No Transcript)
23
(No Transcript)
24
Palcom SoftwarePAL-AT and LiquidWatch
  • Palcom allows remote control of up to 254 panels
    with the ability to review TDR traces, review the
    history of each unit and to pull down a Cad
    drawing for each system for location of leaks,
    breaks, shorts or probe activation's.

25
Archive Data
  • POWER LOST AT 8985 ON 18/95 RESTORED AT 0853 ON
    5/8
  • YEAR CHANGED FROM 29 TO 98 AT 0853 ON 5/8
  • CABLE 1 SETUP, WITH LENGTH OF 514 FEET AT 0921
    ON 5/8
  • LEAK DETECTED IN CABLE 3 at 225 FEET AT 1157 ON
    5/8
  • ALARM ON CABLE 3 SILENCED AT 1157 ON 5/8
  • CABLE 4 SETUP, WITH LENGTH OF 538 FEET AT 1208
    ON 5/8
  • SECURITY CODE 1 ENTERED, LEVEL 250 AT 1210 ON
    5/8
  • NEW CABLE 4 REFERENCE, STORED AS MAP 1 AT 1210
    ON 5/8
  • CABLE 4 MONITORING ON, MAP 1 AT 1210 ON 5/8/98
  • CABLE 4 RETURNED TO NORMAL AT 1211 ON 5/8
  • SECURITY CODE 1 ENTERED, LEVEL 250 AT 1217 ON
    5/8
  • CABLE 3 SETUP, WITH LENGTH OF 833 FEET AT 1217
    ON 5/8
  • NEW CABLE 3 REFERENCE, STORED AS MAP 1 AT 1217
    ON 5/8
  • CABLE 3 MONITORING ON, MAP 1 AT 1217 ON 5/8/98
  • CABLE 3 RETURNED TO NORMAL AT 1218 ON 5/8
  • SECURITY CODE 1 ENTERED, LEVEL 250 AT 1225 ON
    5/8
  • CABLE 2 SETUP, WITH LENGTH OF 815 FEET AT 1225
    ON 5/8
  • NEW CABLE 2 REFERENCE, STORED AS MAP 1 AT 1225
    ON 5/8
  • CABLE 2 MONITORING ON, MAP 1 AT 1225 ON 5/8/98

26
Benefits of PermAlerts PAL-AT
  • Wet cable startup
  • Multiple Leak location capability
  • Location of Breaks
  • Detection of Shorts versus Leaks
  • Not susceptible to contamination from dirt/dust,
    etc.
  • Archive History Data
  • UL Listed, FM Approved, CE Approval available
    Class 1 Div 1 Groups C D Sensor Circuits
  • Up to 8 circuits and 7,500 (2500 m) per circuit
  • Corrosion resistant sensor cables
  • Different cable types on the same circuit
  • EPA third party tested

27
Benefits of LiquidWatch
  • Modular in design allowing for easy expansion
  • Monitoring of probes for activation and the
    leader cable for breaks and shorts
  • History log of events
  • UL Listed for Class 1 Div 1, Groups C D
    locations
  • Different probe types
  • Probe adaptor to allow interface of any dry
    contact probe device

28
Questions and Answer Period