Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure - PowerPoint PPT Presentation

About This Presentation
Title:

Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure

Description:

... 2+=2.5 Uncorrected and best-corrected distance visual acuity at 3 and 6 ... Reduces endothelial cell loss Reduce postoperative endophthalmitis ... – PowerPoint PPT presentation

Number of Views:87
Avg rating:3.0/5.0
Slides: 12
Provided by: CBAT2
Category:

less

Transcript and Presenter's Notes

Title: Evaluation of a complete 1.8 mm coaxial microincision cataract (C-MICS 1.8) procedure


1
Evaluation of a complete 1.8 mm coaxial
microincision cataract (C-MICS 1.8) procedure
  • J. E. Jay McDonald, II M.D.
  • McDonald Eye Associates
  • Fayetteville, Arkansas
  • www.mcdonaldeye.com

Financial disclosure Bausch and Lomb
Consultant Addition Technology - Advisory Board
Santen - Research Support Acufocus - Research
Support Alcon Pharmacology - Speaker Bureau
Wave Tec Research Support Inspire
Consultant Revitalvision, Inc. - Advisory Board
2
Coaxial Microincision Cataract Surgery (MICS)
  • The trend in cataract surgery is toward smaller
    incisions
  • Coaxial MICS (C-MICS)
  • Use current phaco technique
  • Reduce surgically induced astigmatism (SIA)1-3
  • Increase wound sealability4
  • Reduce endothelial cell loss5
  • Heg Wee Jin. WOC 2008, Hong Kong.
  • Braga-Mele R. ASCRS in San Francisco, CA, April,
    2009.
  • Barrett GD. APAO Congress. Bali, Indonesia, May,
    2009.
  • Barrett GD, Carlsson A. Canadian Ophthalmological
    Society, Montreal, Canada, June, 2007.
  • Zafirakis P. ASCRS in San Francisco, CA, April,
    2009.

3
Complete MICS System
  • Stellaris system for 1.8 mm phaco
  • Akreos MICS IOL implantable through 1.8 mm
    incision

4
Stellaris 1.8 Coaxial MICS
  • Only system designed for coaxial 1.8 mm
    microincision cataract surgery (C-MICS)
  • Easy transition from small-incision to
    microincision surgery
  • StableChamber fluidics enhances followability,
    holdability and chamber stability

5
Akreos MICS IOL
  • Akreos MICS lens inserts through 1.8 mm phaco
    incision
  • 30 thinner than Akreos AO lens
  • Aspheric aberration-free optic
  • Moderate refractive index
  • 360 posterior square-edge design

6
Study
  • Retrospective chart review
  • All procedures by same surgeon in same OR
  • Millenium small incision cataract surgery (SICS)
    2.8 mm (n45)
  • Eyes implanted with SofPort AO or Crystalens IOL
  • Stellaris 1.8 mm MICS (n63)
  • Eyes implanted with Akreos MICS IOL
  • EPT, cataract density assessed perioperatively
  • Flare/cells assessed 3.5-5.0 hours postop
  • Trace0.5, 11.0, 1-1.5, 22.0, 22.5
  • Uncorrected and best-corrected distance visual
    acuity at 3 and 6 months
  • Some eyes targeted for monovision measured
    uncorrected and best-corrected near VA at 3 and 6
    months

7
Results
SICS MICS P-value
Cataract Density 2.12 2.15 0.7745
EPT 3.9 4 0.7851
Cells/Flare 1.78 1.26 0.0001
8
Mean Distance Visual Acuity
3M UCVA 3M BCVA 6M UCVA 6M BCVA
2.8 mm SICS 20/34 20/25 20/26 20/24
1.8 mm MICS 20/27 20/21 20/25 20/21
9
3 Month Distance Visual Acuity
10
6 Month Distance Visual Acuity
11
Conclusion
  • Microincision cataract surgery results in a
    quieter postoperative eye than small incision
    cataract surgery
  • Minimizing incision size in cataract surgery may
    also
  • Decrease surgically induced astigmatism
  • Improves wound strength and integrity
  • Reduces endothelial cell loss
  • Reduce postoperative endophthalmitis
  • Reduce patient recovery time