Title: LEED 2.2 for New Construction LEED 2.0 for Existing Buildings
1LEED 2.2 for New ConstructionLEED 2.0 for
Existing Buildings
2LEED NC Rating System Established by the U.S.
Green Building Council
- Menu Driven 69 Point System
- Certified 26 32 Points
- Silver 33 38 Points
- Gold 39 51 Points
- Platinum 52 69 Points
3LEED Rating System Categories
- Sustainable Sites 14 Pts
- Water Efficiency 5 Pts
- Energy Atmosphere 17 Pts
- Materials Resources 13 Pts
- Indoor Environmental Quality 15 Pts
- Innovation and Design Process 5 Pts
- Total 69 Pts
4Sustainable Sites 14 Pts
- Prerequisite Construction Activity Pollution
Control - Site Selection 1 Pt
- Development Density Community
- Connectivity 1 Pt
- Brownfield Redevelopment 1 Pt
- Alternative Transportation 4 Pts
- Reduced Site Disturbance 2 Pts
- Stormwater Management 2 Pts
- Reduce Heat Island 2 Pts
- Light Pollution 1 Pt.
5Water Efficiency 5 Pts
- Water Efficient Landscaping 2 Pts
- Innovative Waste Water Technologies 1 Pt
- Water Use Reduction 2 Pts
6Energy Atmosphere 17 Pts
- Prerequisites
- Fundamental Commissioning
- Minimum Energy Performance
- CFC Reduction HVACR
- Optimize Energy Performance by 14 for New or 7
for Existing Buildings
7Energy Atmosphere 17 Pts
- Optimize Energy Performance 10 Pts
- On-Site Renewable Energy 3 Pts
- Enhanced Commissioning 1 Pt
- Ozone Depletion 1 Pt
- Measurement Verification 1 Pt
- Green Power 1 Pt
8Materials Resources 13 Pts
- Prerequisite Storage and Collection of
Recyclables - Building Reuse 3 Pts
- Construction Waste Management 2 Pts
- Materials Reuse 2 Pts
- Recycled Content 2 Pts
- Regional Materials 2 Pts
- Rapidly Renewable Materials 1 Pt
- Certified Wood 1 Pt
9Indoor Environmental Quality 15 Pts
- Prerequisites
- Minimum IAQ
- Environmental Tobacco Smoke Control
10Indoor Environmental Quality 15 Pts
- OutdoorAir Delivery Monitoring 1 Pt
- Increased Ventilation 1 Pt
- Construction IAQ Management 2 Pts
- Low Emitting Materials 4 Pts
- Indoor Chemical Pollutant Source
Control 1 Pt - Controllability of Systems 2 Pts
- Thermal Comfort 2 Pts
- Daylight Views 2 Pts
11Innovation Design Process 5Pts
- Innovation in Design 4 Pts
- LEED Accredited Professional 1 Pt
12LEED EB Rating System Established by the U.S.
Green Building Council
- Menu Driven 85 Point System
- Certified 32 39 Points
- Silver 40 47 Points
- Gold 48 63 Points
- Platinum 64 85 Points
- Focuses on Building Operations, with renewal
certification every 1-5 years
13LEED Rating System Categories
- Sustainable Sites 14 Pts
- Water Efficiency 5 Pts
- Energy Atmosphere 23 Pts
- Materials Resources 16 Pts
- Indoor Environmental Quality 22 Pts
- Innovation and Design Process 5 Pts
- Total 85 Pts
14Sustainable Sites 14 Pts
- Prerequisite Erosion Sedimentation Control
- Prerequisite Age of Building 2 years old or
LEED Certified - Green Site Exterior Maintenance 2 Pt
- Development Density Community
- Connectivity 1 Pt
- Alternative Transportation 4 Pts
- Reduced Site Disturbance 2 Pts
- Stormwater Management 2 Pts
- Reduce Heat Island 2 Pts
- Light Pollution 1 Pt.
15Water Efficiency 5 Pts
- Prerequisite Minimum Water Efficiency
- Prerequisite Discharge Water Compliance
- Water Efficient Landscaping 2 Pts
- Innovative Waste Water Technologies 1 Pt
- Water Use Reduction 2 Pts
16Energy Atmosphere 23 Pts
- Prerequisites
- Fundamental Commissioning
- Minimum Energy Performance Energy Star 67 - 17
Reduction Relative to National Building Market - Ozone Protection
17Energy Atmosphere 23 Pts
- Optimize Energy Performance 10 Pts
- Renewable Energy On/Off -Site 4 Pts
- Building Operations Maintenance 3 Pts
- Additional Ozone Protection 1 Pt
- Performance Measurement 3 Pt
- Document Emissions Impact 1 Pt
- Documenting Sustainable Building
- Cost Impacts 1 Pt
18Materials Resources 16 Pts
- PrerequisitesWaste Stream Audit/Recycling
- Prerequisite Reduced Mercury in Light Bulbs
- Construction Waste Management 2 Pts
- Optimize Alternative Materials 5 Pts
- IAQ Complaint Materials 2 Pts
- Sustainable Cleaning Products
- Materials 3 Pts
- Occupant Recycling 30/40/50 3 Pts
- Additional Reduced Mercury 1Pt
19Indoor Environmental Quality 22 Pts
- Prerequisites
- Minimum IAQ
- Environmental Tobacco Smoke Control
- Asbestos Removal/Encapsulation
- PCB Removal
20Indoor Environmental Quality 22 Pts
- OutdoorAir Delivery Monitoring 1 Pt
- Increased Ventilation 1 Pt
- Construction IAQ Management 1 Pt
- Documenting Productivity Impacts 2 Pts
- Indoor Chemical Pollutant Source Control 2 Pt
- Controllability of Systems 2 Pts
- Thermal Comfort 2 Pts
- Daylight Views 4 Pts
- Contemporary IAQ 1 Pt
- Green Cleaning 6Pts
21Innovation Design Process 5Pts
- Innovation in Design 4 Pts
- LEED Accredited Professional 1 Pt