PETROBRAS - Petróleo Brasileiro S.A.
2002 GAS-LIFT WORKSHOP
Gas-lift Automation Pilot Project
HOUSTON - FEBRUARY, 2002
Edson Henrique Bolonhini PETROBRAS -
UN-RNCE Galileu Paulo Henke Alves de
Oliveira PETROBRAS - UN-BC
2
Gas-lift automation - TARGETS
  • GUIDELINES
  • control Pwf (bottom hole flowing pressure)
  • action over Pcas (wellhead casing pressure)

3
Gas-lift automation - TARGETS (cont.)
  • OBJECTIVES
  • to get the minimum Pwf by controlling Pcas
  • to observe the well delay time after a change in
    Pcas
  • to verify the adequacy of a PID controller for
    Pcas
  • to verify the adequacy and controllability of
    globe valves for lift-gas injection
  • to observe the effects of ambient temperature on
    Pwf

4
Hardware
  • Instruments
  • bottom hole pressure transmitter
  • wellhead flowing pressure transmitter
  • gas-lift supply pressure transmitter
  • gas-lift rate transmitter
  • gas-lift control valve
  • ambient temperature transmitter
  • data acquisition and control module

5
The well
Tubing Ø 2 3/8 Casing Ø 5 1/2 Depth 1500
m Gas-lift valves Ø 1/8 2 IPO 1 venturi Liquid
flowrate 25 m3/d GOR 130 BSW 35
Bottom hole pressure and temperature transmitter
1500 psi / 100 C
6
Instruments
Control valve globe Ø ¾
Radio and data acquisition and PID control
7
Monitoring
Supervision and control room
8
Results
Data obtained from Dec/2001 until Jan/2002
9
Flow regime effects on Pwf
Oscillation
Heading
10
Ambient temperature effects on Pwf
Night
Day
11
PID control on casing pressure
12
Automatic reactivation - Pwf gt 53 kgf/cm2
PID action
Reactivation algorithm
Gas compressor shutdown
Gas compressor start-up
13
Condensate effects on Pwf
Injecting gas through the 2nd GLV Circulating
liquid through Venturi GLV
Reactivation algorithm Pwf gt 53 kgf/cm2
Rain
14
Final remarks
  • Conclusions
  • It is possible to control the Pwf behaviour
    through the proposed approach
  • PID controller-globe valve assembly showed to be
    efficient and beneficial
  • Ambient temperature has effect on the well
    behavior and it shows the importance of a dynamic
    injection control
  • The experiment allowed us to evaluate the system
    response with time
  • A global control algorithm should consider the
    conditioning of Pwf signal and its tendency

15
PETROBRAS - Petróleo Brasileiro S.A.
2002 GAS-LIFT WORKSHOP
Gas-lift Automation Pilot Project
HOUSTON - FEBRUARY, 2002
Edson Henrique Bolonhini PETROBRAS -
UN-RNCE Galileu Paulo Henke Alves de
Oliveira PETROBRAS - UN-BC