Title: Structure Validation: How to distinguish GOOD and reliable single crystal structures from BAD and UGLY reports
1Structure ValidationHow to distinguish GOOD and
reliable single crystal structures from BAD and
UGLY reports
- A.L.Spek
- Utrecht University
- The Netherlands
21964 Nobel Lecture Dorothy Hodgkin
- . The great advantage of X-ray analysis as
a method of chemical structure analysis is its
power to show some totally unexpected and
surprising structure with, at the same time,
complete certainty. ..
3With Complete Certainty ?
- Yes, in most cases, in particular in the hands of
experienced investigators. - No, when proper scientific procedures have been
ignored. - This presentation will address a number of
obvious cases where proper procedures were
ignored, resulting in erroneous science. - Automated Structure Validation is offered as a
tool to add a qualifier Good (Correct),
Bad(False) or Ugly(Poor) to a structural study.
4THE STABLE PENTAMETHYLCYCLOPENTADIENYL
CATION J.B.Lambert et al. Angew. Chem. Int. Ed.
2002, 41, 1429-1431
5HOT STRUCTURE FAST LANE PUBLICATION
6Pentamethylcyclopentadienyl Anion (Cp-)
-
7 PENTAMETHYLCYCLOPENTADIENYL CATION
ASSIGNED BOND-TYPES
8Enthusiastic Last Paragraph of CE-News
- The Northwestern chemists are now exploring the
reactivity of C5Me5. You can sit down and write
lots of interesting reactions on paper, Lambert
says, and it will be interesting to see if the
molecule reacts as expected. But Considering this
cations track record, it might be safer to
expect more surprises. !!
9NOT SO HOT AFTER ALL !!
Editors Note in the next issue of Angewandte
Chemie
10Strange Bond Pattern and Ring pucker
DoD
Double Bond ?
PACKING EFFECTS ??
11Corrected StructureJ.N. Jones et al.,Chem. Comm.
2002,1520-1521
12Where did it go Wrong ?
- First impression of the structure was likely
based on a preliminary result (plot) without
H-atoms. - Rushed as a short communication into the
prestigious high impact journal Angewandte
Chemie. - Ignoring all counter evidence.
- No experienced crystallographer as referee ?
- No unbiased automated CIF-validation.
13Validation of the Deposited CIF
?
?
14WHY AUTOMATED STRUCTURE VALIDATION?
- See Previous Case Study.
- IN THE PAST
- Single crystal structures determined by
professional crystallographers (Dorothy Hodgkin) - Using serial detectors ( 50 datasets/year).
- Using (open source) software they knew in detail.
- Structures were analyzed and discussed in great
detail. - Papers containing crystallographic results were
refereed by fellow crystallographers.
15Why Automated Validation?
- PRESENT
- - Diminishing number of professional small
molecule crystallographers (sites, teaching). - Many crystal structures done by chemists
- with limited crystallographic background.
- Using CCD detectors ( 1000 datasets/year when
pushed and given enough slaves). - Crystal structures solved using Black-Box
crystallographic firmware (SHELXTL etc.)
16Why Automated Validation?
- PROBLEMS
- Exploding of structural papers to review.
- Limited of referees with sufficient time and
crystallographic knowledge. - Limited supporting information available
- for the reviewer (footnote/deposited).
- Papers including structural evidence are
increasingly refereed by non-crystallographers,
unaware of the many potential pitfalls.
17SOLUTION
- The solution for the problem pioneered by
the - International Union of Crystallography
- Provide and archive structural data in computer
readable CIF format. - Automated validation, with a computer generated
report for authors and referees. - Journals enforcing a structure validation
protocol. - - IUCr journals and most major journals now
implement validation procedures.
18THE CIF DATA STANDARD
- Driving Force Syd Hall (IUCr/ Acta Cryst C)
- Early Adopted by XTAL SHELX(T)L.
- Currently WinGX,Crystals,Texsan, Maxus etc.
- Acta Cryst. C/E Electronic Submission
- Acta Cryst.Automatic Validation at the Gate
- CIF data available for referees for detailed
inspection (and optional calculations). - Data retrieval from the WEB for published papers
- CCDC Deposition in CIF-FORMAT.
19VALIDATION QUESTIONS
- Single crystal validation addresses three
- important questions
- 1 Is the reported information complete?
- 2 What is the quality of the analysis?
- 3 Is the Structure Correct?
20IUCR-CHECKCIF
- IUCR-TESTS
- MISSING DATA, PROPER PROCEDURE, QUALITY
- PLATON TESTS
- SYMMETRY, GEOMETRY, DISPLACEMENT PARAMETERS,
VOIDS, TWINNING etc. - ALERTS
- ALERT A - SERIOUS PROBLEM
- ALERT B - POTENTIALLY SERIOUS PROBLEM
- ALERT C - CHECK EXPLAIN
21ALERT TYPES
- 1 - CIF Construction/Syntax errors,
- Missing or Inconsistent Data.
- 2 - Indicators that the Structure Model
- may be Wrong or Deficient.
- 3 - Indicators that the quality of the results
- may be low.
- 4 - Cosmetic Improvements, Queries and
- Suggestions.
22Problems Addressed by PLATON
- Missed Higher Space Group Symmetry
- Solvent Accessible Voids in the Structure
- Unusual Displacement Parameters
- Hirshfeld Rigid Bond test
- Misassigned Atom Type
- Population/Occupancy Parameters
- Mono Coordinated/Bonded Metals
- Isolated Atoms (e.g. O, H, Transition Metals)
23Problems Addressed by PLATON
- Too Many Hydrogen Atoms on an Atom
- Missing Hydrogen Atoms
- Valence Hybridization
- Short Intra/Inter-Molecular Contacts
- O-H without Acceptor
- Unusual Bond Length/Angle
- CH3 Moiety Geometry
- To be extended with tests for new problems
invented by authors.
24Problems Addressed by PLATON
- Reflection Data (.fcf)
- Sufficient Resolution
- Completeness of the data set
- Missed (Pseudo-) Merohedral Twinning
- Friedel pairs
- S
25The Missed Symmetry Problem
- Up to 10 of the structures in space groups such
as Cc have higher symmetry (e.g. C2/c, R-3c, Fdd2
etc.) than was originally reported. - (To be Marshed is not good for your scientific
reputation). - MISSYM PLATON/ADDSYM algorithm addresses the
problem. - EXAMPLE gt
26Praseodymium complex
J.A.C.S. (2000),122,3413 P1, Z 2
27CORRECTLY REFINED STRUCTURE
P-1, Z2
28Validation with PLATON
- - Details www.cryst.chem.uu.nl/platon
- Driven by the file CHECK.DEF with criteria, ALERT
messages and advice. - Use (UNIX) platon u structure.cif
- Result on file structure.chk
- Applicable on CIFs and CCDC-FDAT
29Example of Misplaced Hydrogen Atom
30Two ALERTS related to the misplaced Hydrogen Atom
31Unsatisfactory Hydrogen Bond Network
32Satisfactory Hydrogen Bond Network with new
H-position
33Characterization of compound isolated from marine
invertebrate
Lindquist et al., J. Amer. Chem. Soc.
(1991),113,2303-2304.
34Synthesis Li et al. (2001) Angew. Chem. 113,
4901 -gtSurprise
Solution of the riddle Li et al. (2001) Angew.
Chem. 113,4906 O --gt N-H (Analysis of the
Displacement Ellipsoids)
35Automatic Validation of the coordinate data taken
from the CSD
Result Alert on short intermolecular OO Contact
36O
N
Infinite hydrogen bonded chain
N-HOC
37Wrong Structure
- Sometimes automatic procedures can come up with
reasonably looking but wrong structures. - Structure validation software should send out
proper ALERTS to the investigators - (e.g. IUCr Checkcif)
- Example (Structure submitted to Acta Cryst. C)
The chemist involved expects a Cu-complex, so
that is what he reports (confirmed by X-ray
crystallography !) and tries to publish and
fortunately caught by a knowledgeable referee
38R lt 7
Cu not Coordinated gt
ORTEP of the False Structure
39R lt 6
Ortep of the Correct Structure
40Thus
- The original paper indeed mentioned an
interesting uncoordinated Cu2 but left it with
this statement. - The chemistry changed from Cu2L2- to
LBr- by also adding some missed Hydrogen
atoms. - HBr was used in the synthesis.
- Various ALERTS pointed to the problem but ignored
by the authors. - Interestingly, the color of the crystal changed
from green to colorless in the revised paper ..
41Entry from the CSD
H
S
42But with Space Group Symmetry
gt Different structure with S-S Bond !
43COMMENTS
- Validation should not be postponed to the
publication phase. All validation issues should
be taken care of during the analysis. - Everything unusual in a structure is suspect,
- mostly incorrect (artifact) and should be
investigated and discussed in great detail and
supported by independent evidence. - - The CSD can be very helpful when looking for
possible precedents (but be careful)
44CONCLUSION 1
- Validation Procedures are excellent Tools to
- Set Quality Standards (Not just on R-Value)
- Save a lot of Time in Checking, both by the
Investigators and the Journals (referees) - - Point at Interesting Features
(Pseudo-Symmetry, - short Interactions etc.) to be discussed.
- Surface a problem that only an experienced
Crystallographer might be able to Address - Proof the Routine Status of the Determination
in the Hands of its Investigator
45Conclusion 2
- Dorothy Hodgkins claim that X-ray
crystallography can deliver new science is still
valid as it was in 1964, - Given
- Correct procedures
- Structure validation
- Education
46Residual Problem
- EDUCATION
- Response of an author of a structural paper
submitted to the crystallographic journal Acta
Cryst. to an enquiry from a referee on the
reported space group - Please teach me, what does in mean
- space group incorrect
47Additional Info
- http//www.cryst.chem.uu.nl
- Thanks
- for your attention !!