Title: Compatibility of MP membranes and O3


1
Compatibility of MP membranes and O3
  • Membranes as O3 contactors
  • Materials under study
  • Experimental Procedure
  • Compatible or not compatible ?
  • Conclusions

2
Membranes for O3 contacting Several benefits!
  • O3 in water treatment
  • MP membranes feasible for O3 mass transfer?

off-gas treatment
  • - Different contactor types, characteristics
    performance
  • - Membrane contactors
  • off-gas can be recycled,
  • bubble-free,
  • scaling,
  • moderate to fast mass transfer (high kLa values)

3
Compatibility of MP membranes and O3
  • Membranes as O3 contactors
  • Materials under study
  • Experimental Procedure
  • Compatible or not compatible ?
  • Conclusions

4
Original and chemically modified membrane
materials under study
  • MP polymeric ultra-filtration membrane tubes
  • Membrane test assembly
  • PVC outer tube, MP membranes inside
  • Water flow inside the membranes, O2/O3 flow
    outside the membranes
  • 1 Assembly with original membrane tubes
  • 1 Assembly with chemically modified membranes

5
Compatibility of MP membranes and O3
  • Membranes as O3 contactors
  • Materials under study
  • Experimental Procedure
  • Compatible or not compatible ?
  • Conclusions

6
Methods Ozonation of membrane tubes
  • Set-up Batch ozonation of MP membrane tubes

7
Methods Ozonation of membrane tubes
  • Experimental conditions
  • 5 pieces from 3 different membrane tubes
  • Visual observation of damage ? weigth before -
    after
  • Milli-Q water, near-neutral pH, RT
  • Ozonation 3.5 7.3 6.0 hours, O3liq
    8.28.6 mg/L
  • Monitoring of pH, ORP, conductivity, O3gas,
    O3liq, T,
  • UV/VIS

8
Methods Test assembly
  • Test assembly
  • Milli-Q water, near-neutral pH, RT
  • Water flow peristaltic pump
  • O3gas 50 g/m3
  • Set-up

9
Compatibility of MP membranes and O3
  • Membranes as O3 contactors
  • Materials under study
  • Experimental Procedure
  • Compatible or not compatible ?
  • Conclusions

10
Ozonation of membrane tubes clear indication
of degradation
  • Visual observations (after 17 hours ozonation)
  • Dispersion of white particles in solution
  • Increased surface roughness, loss of flexibility
  • Mass balance
  • mass loss after ozonation periods points at
    degradation
  • UV/VIS Conductivity
  • build-up of degradation products in solution
  • pH
  • decrease in pH caused by formation of
    carboxylic acids (?)

11
Test assemblies MP membranes incompatible
with O3
  • Both test assemblies damage after lt 50 minutes
    O3 flow!

12
Compatibility of MP membranes and O3
  • Membranes as O3 contactors
  • Materials under study
  • Experimental Procedure
  • Compatible or not compatible ?
  • Conclusions

13
MP membranes and O3 incompatible ?
  • Nor original, neither modified MP
    ultra-filtration membranes are resistant to O3
  • MP membranes cannot be used for O3 contacting
    despite low O3liq in disinfection (typically
    0.1 1 mg/L)
  • ? degradation concentration exposure !
  • Ozonated water streams need to be separated from
    filter units in the dishwashers!