The Letter Report - PowerPoint PPT Presentation

About This Presentation
Title:

The Letter Report

Description:

The Letter Report When is it appropriate? Who is the audience? Characteristics 3-5 pages 0-3 tables or figures emphasize important points avoid details choose words ... – PowerPoint PPT presentation

Number of Views:49
Avg rating:3.0/5.0
Slides: 14
Provided by: Davi1340
Learn more at: https://my.che.utah.edu
Category:

less

Transcript and Presenter's Notes

Title: The Letter Report


1
The Letter Report
  • When is it appropriate?
  • Who is the audience?

2
Characteristics
  • 3-5 pages
  • 0-3 tables or figures
  • emphasize important points
  • avoid details
  • choose words carefully
  • avoid repetition
  • Concise Writing!

3
No Title Page
  • no title
  • authors sign letter
  • date is in letter format
  • affiliation is in letterhead
  • position is with signature

4
No Headings or Numbered Sections
  • no table of contents
  • no list of figures
  • no list of tables
  • no list of references
  • Use footnotes

5
Summary and Introduction
  • no separate sections
  • must present purpose and state important results
    early in the paper (first paragraph)
  • lacks repetition of a formal report

6
References
  • treated as footnotes
  • only a few references
  • no list of references

7
Tables and Figures
  • same format as in other reports
  • Few in number!
  • Only the important ones
  • should be self-contained documents
  • place
  • at end of letter
  • or within letter

8
No Nomenclature Section
  • all symbols must be defined as they are
    introduced
  • use only important equations

9
Backup Information
  • raw data
  • calculations
  • error analysis
  • experimental equipment
  • experimental procedures

10
Outline
  • recipient and address
  • salutation
  • project objective
  • important results
  • description of experimental procedures - very
    brief, innovative techniques, problems encountered

11
Outline continued
  • results - analysis - discussion
  • recommendations
  • signature

12
205 East 2nd South Apt 6 SLC, Utah
84103 February 6, 1992 Professor Noel de
Nevers Department of Chemical Engineering
University of Utah Salt Lake City, Utah
84112 Dear Dr. de Nevers During the period
from January 6 to January 27, 1992, the members
of Group F calibrated and evaluated the
performance of an Omega Model HX93V
relative-humidity and temperature transmitter
(Omega Engineer., Stamford Connecticut). The
transmitter was calibrated with an Omega
HX92-CAL relative-humidity calibration kit, and
its accuracy was tested with various solutions
of ethylene glycol and water ranging from 10 to
100 relative humidity (RH). The transmitter was
accurate to within 5
13
RH at higher relative humidities (gt50) but was
not accurate to within 5 RH at humidities lower
than 50. The transmitter's performance in a
moving airstream at temperatures greater than
room temperature was also investigated. A
cardboard tube and an air blower containing a
heating element supplied a suitable stream of
heated air. A brief summary of the calibration
and the results of our performance evaluation
follow .
Write a Comment
User Comments (0)
About PowerShow.com