Linac Test Area Instrumentation - PowerPoint PPT Presentation

About This Presentation
Title:

Linac Test Area Instrumentation

Description:

Experiment - RF, Solenoid solenoid current 1 rad level on chipmunks 10? Cavity forward power 1 cavity reflected power 1 cavity RF level (E-field?) 2 ... – PowerPoint PPT presentation

Number of Views:29
Avg rating:3.0/5.0
Slides: 11
Provided by: Debbi120
Learn more at: http://agni.phys.iit.edu
Category:

less

Transcript and Presenter's Notes

Title: Linac Test Area Instrumentation


1
Linac Test Area Instrumentation
  • D. Errede, M. Haney (UIUC)
  • M. Shea (FNAL)
  • MuCool
  • Feb 6, 2002

2
Problem What are the signals to be readout from
the LTA?
  • Beam Line (Carol Johnstone)
  • Beam Properties Measurements (CJ)
  • Cryogenics (Barry Norris)
  • A. H2
  • B. He
  • Experiment
  • A. Absorbers (Mary Anne Cummings, Edgar Black)
  • B. RF Cavities (Al Moretti)
  • C. Solenoid (Al Moretti)

3
Beam Line Elements
signals
  • 750 KeV Chopper 1
  • dipole magnets currents 5
  • quad magnet currents 13
  • stripping foil 1
  • collimater positions - 2 units 8
  • ion chamber 1 (in front of beam dump)

4
Beam Properties Measurements
signals
  • Tune Parameters ? data set
  • Beam Position Monitors 20-40
  • Toroid Beam Current Monitor 1 (slow response)
  • Fast Beam Current Monitor 1 (fast response)
  • Beam Loss Monitors 5-10

5
Cryogenics
signals
  • Helium
  • inlet temp (carbon) 1
  • outlet temp (carbon) 1
  • inlet temp (platinum) 1
  • outlet temp (platinum) 1
  • inlet pressure 1
  • outlet pressure 1
  • He level 2
  • N2 level 1
  • solenoid coil temperature (platinum) 4

6
Cryogenics
Hydrogen
  • inlet temp(carb) 1
  • outlet temp(carb) 1
  • inlet temp (plat) 1
  • outlet temp (plat) 1
  • temperature other 6
  • inlet pressure 1
  • outlet pressure 1
  • pump delta press 1
  • H2 supply press 1
  • H2 vent press 1
  • H2 vent pipe press 1
  • cryo vacuum press 2
  • pump status (run/not) 1
  • pump voltage 1
  • pump current 1
  • pump speed 1
  • heater voltage 1
  • heater current 1
  • heater power 1
  • beam permit 1
  • hazardous gas 10
  • O2 deficiency hazard 8

7
Experiment - Absorber
signals
  • temperature 12
  • pressure transducers see under cryo
  • photogrammetry (??) 2
  • laser occlusion sensor (??) 4
  • piezo vibration sensors 2
  • strain gauges 2
  • bolometry ??
  • O2 sensors 3per each of 5 flanges 15
  • H2 sensors on exhaust line 10
  • CCD camera 2 images
  • MICE channels ??

8
Experiment - RF, Solenoid
signals
  • solenoid current 1
  • rad level on chipmunks 10?
  • Cavity forward power 1
  • cavity reflected power 1
  • cavity RF level (E-field?) 2
  • cavity vacuum level 2
  • timing channels 10?

9
Picture of cryo/absorber assembly
10
Time schedule
Write a Comment
User Comments (0)
About PowerShow.com