E-mail from Dave MacNair concerning bench measurements made on SCOR-6 type corrector power supplies, as presently used in sectors 21-30: - PowerPoint PPT Presentation

About This Presentation
Title:

E-mail from Dave MacNair concerning bench measurements made on SCOR-6 type corrector power supplies, as presently used in sectors 21-30:

Description:

E-mail from Dave MacNair concerning bench measurements made on SCOR-6 type corrector power supplies, as presently used in sectors 21-30: With the standard load, at a ... – PowerPoint PPT presentation

Number of Views:71
Avg rating:3.0/5.0
Slides: 6
Provided by: PaulE160
Category:

less

Transcript and Presenter's Notes

Title: E-mail from Dave MacNair concerning bench measurements made on SCOR-6 type corrector power supplies, as presently used in sectors 21-30:


1
E-mail from Dave MacNair concerning bench
measurements made on SCOR-6 type corrector power
supplies, as presently used in sectors 21-30
2
(No Transcript)
3
(No Transcript)
4
(No Transcript)
5
Summary
  • With the standard load, at a 3-ampere setting
    (half of maximum output), and for frequencies, f,
    between 240 Hz gt f gt 0.5 Hz, the SCOR-6 corrector
    power supplies regulate at an rms of 310-5 with
    respect to their full 6-ampere output scale.
  • A significant component of this is a 60-Hz
    ripple.
  • This regulation improves at a zero-current
    setting to 0.410-5 and becomes worse at the full
    6-ampere setting, to 410-5.
  • This is 10-times better than was originally
    expected.
  • It means that these correctors can be used for
    the LCLS, probably in sectors 22-30, but must be
    upgraded in sector 21, and possibly sector 22
    (work in progress).