Title: WE, SAHARA DIAGNOSTICS, WELCOME YOU TO QBC- MALARIA, FILARIA (BY FLUORESCENT MICROSCOPY) PRESENTATION.
1WELCOME
- WE, SAHARA DIAGNOSTICS, WELCOME YOU TO QBC-
MALARIA, FILARIA (BY FLUORESCENT MICROSCOPY)
PRESENTATION.
2SCENARIO OF MALARIA IN ORISSA
- MALARIA - STILL A GIANT KILLER IN THIS 21ST
CENTURY OF MEDICAL ADVANCEMENT. - A REAL CAUSE OF SERIOUS CONCERN !!!!!!!!
- AS PER TIMES OF INDIA PUBLICATION
- ORISSA STILL TOPS THE LIST OF MALARIA DEATHS IN
THE COUNTRY. - MALARIA DEATHS IN 2002 03 ARE 465 AND 333
RESPECTIVELY. - NEARLY 45 OF TOTAL DEATHS IN THE COUNTRY, OCCUR
IN ORISSA ONLY. - ORISSA ALSO COMPRISES 25 OF THE TOTAL MALARIA
CASES IN THE COUNTRY. - IN 2003, THE ENTIRE ORISSA WAS IN GRIP OF DEADLY
FALCIPARUM MALARIA WHICH IS ABOUT 85 OF TOTAL
MALARIA CASES REPORTED.
3- OUT OF 4.17 LAKH MALARIA CASES REPORTED, 3.46
LAKH AFFECTED BY P.F - EVEN OUR CHIEF MINISTER ON THE OCCASION OF
NATIONAL MALARIA PREVENTION MONTH IN JUNE LAST
EXPRESSED SERIOUS CONCERN OVER MALARIA DEATHS IN
ORISSA. - C.M FURTHER EMPHASIZED THAT MALARIA STILL NOT
CONTROLLED AS PER EXPECTATION IN ORISSA DESPITE
THE FACT THAT STATE GOVT. HAS ALREADY SPENT Rs.
14 CRORE OVER A SPAN OF LAST 7 YEARS. - SO, C.M. CALLED FOR IMMEDIATE STEPS TO CONTROL
THIS DEADED DISEASE ON TOP PRIORITY. - WORLD BANK SPONSORED ENHANCED MALARIA CONTROL
PROJECT BEING IMPLEMENTED ALSO IN MOST OF THE
DISTRICTS OF ORISSA
4SAHARAS QBC FROM ( B-D ) , USA, ONLY
ORIGINALTHE MANUFACTURER OF THIS WONDERFUL
MACHINE TO CONTROL MALARIA
- B-D IS MORE THAN 107 YEARS OLD RESEARCH ORIENTED
COMPANY. - KNOWN FOR ITS QUALITY MEDICAL EQUIPMENT
SERVICES WORLD WIDE. - B-D IS THE PATENT HOLDER OF QBC MACHINE.
- QBC IS THE REGISTERED TRADEMARK OF B-D, USA.
- U.S FDA APPROVAL IS GIVEN TO A SYSTEM WHICH
CONFORMS ALL PARAMETERS OF APPLIACTION,
RELIABILITY, SAFETY QUALITY OF THE EQUIPMENT. - NO COMPANY EXCEPT B-D IS AUTHORISED TO USE THE
NAME QBC. - QBC SYSTEM BEING MANUFACTURED BY B-D FOR MORE
THAN 10 YEARS.
5(No Transcript)
6(No Transcript)
7- INNOVATIVE COMPONENETS MAKE OPERATION
ADAPTATION SIMPLE
8(No Transcript)
9(No Transcript)
10HOW QBC SYSTEM WORKS
- 55 65UL OF BLOOD IS TAKEN IN QBC TUBE PRECOATED
INTERNALLY WITH ACRADINE ORANGE STAIN OTHER
REAGENTS. - CLOSURE IS ATTACHED AND A PRECISION FLOAT
INSERTED BEFORE SPINNING THIS TUBE AT 12,000 RPM
IN THE QBC CENTRIFUGE FOR 5 MINUTES. - COMPONENTS OF BUFFY COAT SEPARATES BASED ON THEIR
DENSITIES (WBC AT THE TOP RBC AT BOTTOM OF THE
TUBE).
11(No Transcript)
12(No Transcript)
13WHY QBC SYSTEM WORKS
- KEY TO THE SUCCESS OF THE QBC MALARIA TEST IS
CONCENTRATION - ON CENTRIFUGATION, ALL PARASITIZED RED BLOOD
CELLS LOCATE VISIBLY IN A PREDICTABLE AREA OF THE
QBC TUBE MAKING DETECTION EASY AND FAST. - PARASITIZED RBC ARE LIGHTER IN DENSITY THAN
NORMAL RBC SO THEY CONCENTRATE AT THE TOP OF THE
RBC LAYER.
14- PARASITES CONTAIN DNA WHICH TAKE UP THE ACRIDINE
ORANGE STAIN AND APPEAR AS BRIGHT SPECK OF LIGHT
AMONG NONFLUORESCING RED BLOOD CELLS. - VIRTUALLY ALL PLASMODIA PRESENT IN 60UL OF BLOOD
CAN BE EASILY VISUALISED AS ONE ROTATES THE QBC
TUBE UNDER THE PARALENS.
15HIGH SENSITIVITY
- STANDARD 65UL QBC TUBE CONTAINS NEARLY 500 TIMES
THE VOLUME INSPECTED IN 100 FIELDS OF A THICK
SMEAR. - QBC TEST IS 100 TIMES MORE SENSITIVE FOR LOW
LEVEL PARASITIMIA THAN THE THICK SMEAR. - QBC MALARIA TEST CAN IDENTIFY ALL THE DIFFERENT
SPECIES AND STAGES OF MALARIA LIKE PV, PF,
P.MALARIE P.OVALE WITH STAGES LIKE
TROPHOZOITES, GAMETOCYTES SCHIZONTS ETC. - QUANTIFICATION OF PARASITEMIAS WITH SEVERITY OF
INFECTIONS CAN BE KNOWN. - QUALITATIVE DIFFERENTIAL DIAGNOSIS.
16BENEFITS OF QBC TECHNIQUE
CRITERIA CONVENTIONAL QBC BENEFITS
QUALITY OF BLOOD 4 5UL 55 65UL MORE BLOOD MORE PARASITES
USER TRAINING 8 16 WEEK ONE DAY EASY TO LEARN
STAINING REQUIRED PRECOATED TUBES USED EASY, FAST UNIFORM STAINING
PARASITE LOSS UPTO 40 PARASITE LOST DURING SLIDE PREPARATION NO LOSS OF PARASITE MORE SENSITIVE
SENSITIVITY 100 PARASITE PER 2UL 1 PARASITE PER 2UL 100 TIMES MORE SENSITIVE
CONCENTRATION PARASITES ARE SPREAD PARASITES ARE CONCENTRATED BY CENTRIFUGATION EASE OF DETECTION
READING TIME FOR NEGATIVES 8 10 MINUTES LESS THAN 1 MINUTE QUICKER AND FASTER
17BENEFITS OF QBC MALARIA DETECTION SYSTEM
- FASTER AND ACCURATE DETECTION OF MALARIA PARASITE
IN CAPILLARY AND VENOUS BLOOD NO FALSE NEGATIVE
CASES. - SPECIES IDENTIFICATION IS EASY, FAST AND
ACCURATE. - EARLY DETECTION OF LOW PARASITEMIA BOARDER LINE
CASES.
18- EASY DETECTION FOR PYREXIA OF UNKNOWN ORIGIN
CASES. - MANY LIVES CAN BE SAVED FROM DEADLY P. FALCIPARUM
BY TIMELY AND SPECIFIC DIAGNOSIS. - SIDE EFFECTS OF LONG TERM TREATMENT OF ANTI
MALARIAL DRUGS CAN BE MINIMISED. - AND FINALLY, IT WILL HELP TO CONTROL THE MENACE
OF DEADLY KILLER MALARIA TO A GREAT EXTENT. - IT ALSO DETECTS MICRO FILARIA.
19AS PER WORLD BANK NORM ONLY B-D QUALIFIES ALL THE
CRITERIAS
- B-D HAS DESIGNED QBC AND NOT COPIED.
- B-D HAS MORE THAN 15 YEARS EXPERIENCE IN
MANUFACTURING QBC. - B-D HAS ISO- 9001, U.S FDA AND CE CERTIFICATES
FOR COMPLETE QBC SYSTEM. - QBC SYSTEM USES UV RADIATION WHICH CAN BE
HAZARDOUS FOR HUMAN EYES BUT OUR SYSTEM IS 100
SAFE FOR THE END USERS AS IT IS APPROVED BY U.S
FDA.
20- THANK YOU ALL
- SAHARA DIAGNOSTICS