PATD / ICTS / Test Std. / IG control no. - PowerPoint PPT Presentation

About This Presentation
Title:

PATD / ICTS / Test Std. / IG control no.

Description:

Title: Slide 1 Author: videocon Last modified by: hitesh kumar Created Date: 10/31/2008 10:51:04 AM Document presentation format: On-screen Show (4:3) – PowerPoint PPT presentation

Number of Views:5
Avg rating:3.0/5.0
Slides: 4
Provided by: vide99
Category:
Tags: icts | patd | control | std | test

less

Transcript and Presenter's Notes

Title: PATD / ICTS / Test Std. / IG control no.


1
Quality Bulletin
Horizontal deployment
Running model
New model
Re-FPA
New part approval
Prepared CKD App
Model
Product
Claim section
Claim date
S/No.
Date of imp
REF
Field
24-08-2013
24-08-2013
All Models
Quality issue
Cause
Count measure
  • Water Leakage from Drain Elbow.

Analysis Why? ? Water leakage due to elbow right
angle. Why? ? Improper fitment of drain pan and
elbow in liner.
Temp countermeasure Elbow design modification
done to angular shape (120 Degree angle).
Permanent countermeasure Elbow design
modification done to angular shape (120 Degree
angle).
Before
Improved
References
1. Drain elbow design was at 90 degree
  • Shape design changed from right angle to angular
    (120 degree)

PATD / ICTS / Test Std. / IG control no.
ECN No.
JIR control no.
Others ( Refer OQC/ELT Revision )
2
Quality Bulletin
Horizontal deployment
Running model
New model
Re-FPA
New part approval
Prepared CKD App
Model
Product
Claim section
Claim date
S/No.
Date of imp
REF
Field
24-08-2013
24-08-2013
All Models
Quality issue
Cause
Count measure
  • Water Leakage from Drain pan.

Analysis Why? ? Water leakage due to elbow right
angle. Why? ? Improper fitment of elbow and
drain pan in liner.
Temp countermeasure Drain Pan design
modification done for Knob from straight to
angular position as per drain elbow..
Permanent countermeasure 1. Drain pan design
modification done
Before
Improved
References
1. Drain elbow design was at 90 degree
Drain Pan design modification done for Knob from
straight to angular position as per drain elbow..
PATD / ICTS / Test Std. / IG control no.
ECN No.
JIR control no.
Others ( Refer OQC/ELT Revision )
3
Quality Bulletin
Horizontal deployment
Running model
New model
Re-FPA
New part approval
Prepared CKD App
Model
Product
Claim section
Claim date
S/No.
Date of imp
REF
Field
24-08-2013
24-08-2013
All Models
Quality issue
Cause
Count measure
  • Water Leakage from Drain Elbow.

Analysis Why? ? Water leakage due to elbow right
angle. Why? ? Improper fitment of elbow and
drain pan in liner.
Temp countermeasure Drain Tube design changed
from PVC to LDPE.
Permanent countermeasure Drain Tube design
changed from PVC to LDPE.
Before
Improved
References
  • More flexible pipe

PATD / ICTS / Test Std. / IG control no.
ECN No.
JIR control no.
Others ( Refer OQC/ELT Revision )