Somerset Medical Center - PowerPoint PPT Presentation

1 / 37
About This Presentation
Title:

Somerset Medical Center

Description:

Title: Replacing 12 systems in 12 months; No Problem ? Author: End User Last modified by: S0260630 Created Date: 7/30/2002 2:40:30 PM Document presentation format – PowerPoint PPT presentation

Number of Views:80
Avg rating:3.0/5.0
Slides: 38
Provided by: EndU187
Learn more at: http://www.pamia.org
Category:

less

Transcript and Presenter's Notes

Title: Somerset Medical Center


1
Somerset Medical Center
  • Inet and BMDI
  • Design and Implementation
  • Dennis Dacquel, RN

2
Somerset Medical Center
  • Non-Profit Community Minor Teaching Hospital
  • 355 Licensed bed
  • 261 maintained / 240 average census
  • Annual Statistics
  • 40,000 Emergency visits
  • 30,000 Inpatient Visits
  • 250,000 Outpatient procedures
  • 1420 FTEs (1800 people)
  • 540 Independent Staff Doctors
  • Average LOS 4.9 5.1 days

3
Somerset Medical Center Strategies
  • Top 100
  • Community
  • Teaching
  • Hospitals

4
(No Transcript)
5
Clinical Systems Vision Nursing Process
Automation Redesign
  • Standards of Care
  • Documentation
  • Charge automation
  • Order Processing Results Charting
  • Care Delivery Task Management
  • Medication Management

GOAL MORE TIME FOR PATIENT CARE
6
M1 M2 M3 M4 M5 M6 M7 M8
M9 M10 M11 M12 M24

7
Critical Care Pavilion
  • ICU(8 beds)
  • CCU(12 beds)
  • IMCU(8 beds)
  • 85 Critical Care RNs
  • 1 Intensivist, 1 PA, 1 NP

8
Timeline Summary
9
Project Organization
10
Inet Project Team
  • SMC IS staff
  • Critical Care Clinician Specialist
  • Critical Care Manager
  • Critical Care Director
  • Critical Care Staff
  • Cerner Inet/Documentation Resource
  • Cerner BMDI resource

11
Design and Build
12
Design Sessions
  • Multiple wish-list meetings
  • Ensuring wish-list items are JCAHO compliant.
  • Form design
  • BMDI data acquisition requirements

13
Inet Build
  • Inet OCDs
  • Upload Event Codes
  • Upload Event Sets
  • Create DTAs
  • Turn on the Flowsheets

14
(No Transcript)
15
(No Transcript)
16
(No Transcript)
17
(No Transcript)
18
(No Transcript)
19
(No Transcript)
20
(No Transcript)
21
(No Transcript)
22
(No Transcript)
23
(No Transcript)
24
(No Transcript)
25
Technical Design
  • Local Model
  • - fat client PC with direct multiple serial
    connections to bedside devices for every bed
  • - reference database needs to be copied to every
    PC
  • - troubleshooting
  • - maintenance
  • - hardware

26
Technical Design
  • Centralized Gateway Model
  • - thin clients
  • - 1 BMDI gateway to capture data for all bedside
    devices via TCPIP network
  • - 1 Cerner reference database

27
Hardware needs
  • Purchase ASAP!!!!
  • BMDI gateway
  • Cerner BMDI server
  • Cables/terminal servers/network access etc.

28
BMDI Vendor Selection
  • Cerner only responsible for inbound data
  • Client responsibility to acquire gateway
    solution
  • - HP/Philips
  • - GE
  • - Siemens/Legacy Integrators

29
Siemens/Legacy Centralized Solution
  • Auto device ID detection
  • Port independence - any device / any port.
  • Network based - efficient and fast.
  • Flexibility - 4 ports at the bedside
  • Scalability - deploy in 1 care unit, multiple
    units, or the entire hospital

30
Critical Care Bedside Devices
  • 29 bedside monitors
  • - GE Marquette Unity network
  • 14 ventilators(floating)
  • - Siemens Servo 300
  • 3 IABPs(floating)
  • - Datascope system 97