Title: Visual and refractive outcomes following implantation of innovative Premium multifocal toric IOL after cataract surgery
1Visual and refractive outcomes following
implantation of innovative Premium multifocal
toric IOL after cataract surgery
- NOCHEZ Y, DEBOIS A, SALAH S, PISELLA PJ
- Yannick.nochez_at_free.fr
- C.H.U. Bretonneau, Tours, France
No financial disclosure
2Introduction
- Toric IOLs have been designed to compensate preop
corneal astigmatism.
3PURPOSE
- To assess efficacy, safety and optical quality of
a premium lenses (Lentis Mplus Toric Oculentis,
Berlin, Germany) - to correct astigmatism, refraction,
- and also presbyopia.
4METHODS
- Prospective study.
- Corneal astigmatism greater than 1 diopter
- 6 eyes (3 patients) received a Lentis Mplus Toric
IOL - Single piece, multifocal acrylic lens with and
aspheric posterior surface. - Multifocality archieved by a near sector in the
lower IOL part. - An individual correction of corneal astigmatism
was also provided by this IOL. - Patients underwent MICS through 1.8 mm clear
corneal incision.
5Pre and Post operative parameters
- Keratometry
- Subjective refraction
- Corneal Topography (Atlas 9000, Carl Zeiss
Meditec) - Corneal wavefront analysis and HOA (KR-1,
Topcon) - These parameters were collected before surgery
and 3 months after. - Uncorrected distance and near visual acuity was
also determined.
6- Oculentis calculator
- Using SRK-T formula and IOL Master biometry
76-months postoperative evaluation
- Slitlamp examination (stability, rotation?)
- Best-corrected visual acuity
- Subjective refraction
- Pupillometry
- Objective contrast sensitivities (OQAS,
Visiometrics, Spain) - Corneal Topography and corneal HOAs
- Total ocular aberrations measurement with
hartmann-shack aberrometer
8RESULTS
- Our results indicate that multifocal toric IOL
implantation is a predictable option to correct
preexisting corneal astigmatism.
9- 6 Months postoperative non-corrected distance
visual acuity ? mean value 9,4/10ème (between
7/10ème and 12,5/10ème). - Mean rotation IOL 5,2 /- 3,6 , between 0 and
10.
10Subjective defocus curve
Acrilisa
M Plus
Rezoom
11Objective quality of vision
Objective quality of vision values (OQAS) Lentis monofocal Lentis multifocal toric Proba P
OSI 1,1 0,8 1,34 0,65 pgt0,05
MTFcutoff (c/deg) 33,9 10,45 29,87 7,32 pgt0,05
12CONCLUSION
- Good visual outcomes with uneventful multifocal
toric implantation. - Stable in time Few rotation at 6 months
postoperatively. - Predictable and reliable method for astigmatism
correction in MICS technique - Good intermediate and near vision at 6 months.
- Good predictive refractive error for distance
vision.