By Dr. Attaullah Shah Swedish College of Engineering and Technology Wah Cantt.

presentation player overlay
About This Presentation
Transcript and Presenter's Notes

Title: By Dr. Attaullah Shah Swedish College of Engineering and Technology Wah Cantt.


1
By Dr. Attaullah ShahSwedish College of
Engineering and Technology Wah Cantt.
  • Reinforced Concrete Design-6
  • Shear Design of Beams

2
(No Transcript)
3
(No Transcript)
4
(No Transcript)
5
(No Transcript)
6
(No Transcript)
7
(No Transcript)
8
Flexure Shear Cracking
  • When both the shear force and bending moments
    are large, flexural tension cracks form first.
    When the load is increased further and the
    tension flexural force at theses cracks increases
    than the tensile strength of concrete, shear
    flexural cracks . of RC beams It has been shown
    by research that flexure shear cracking develops
    at
  • The shear strength of reinforced concrete
  • Beams is developed by the following
  • Concrete contribution
  • Aggregates interlocking
  • Dowel action due to longitudinal steel

?cr Vcr/bd 1.9vfc 2500 ? Vd/Mlt3.5
vfc Alternatively ?cr 2vfc
9
RC beams with web reinforcement
  • Before development of diagonal shear cracks,
    there is no noticeable effect of web steel.
  • When the diagonal cracks are intercepted by the
    web steel, these are restricted from further
    extending into compression zone.
  • For the cracked part the web steel restricts the
    cracks width and lead to interface shear.
  • The web reinforcement also check the cracks
    development along the main reinforcement, thereby
    providing restraint against the slitting of
    concrete and leads to shear strength contribution
    also called dowel action.
  • The total shear strength of web/ transverse
    reinforced RC beams is sum of the concrete
    contribution and web steel contribution. i.e.
  • Minimum web reinforcement given by ACI is
  • This provision holds unless Vc is one half or
    less than the design shear stress
  • For floor beams system, beams with total depth
    of 10in or less the maximum spacing may not
    exceed 2 ½ times the slab thickness or one half
    of width of the beam whichever is greater.

Vs Vc Vw (1.9vfc 2500 ? Vd/Mlt3.5
vfc)bd Avfyd/s
10
Types of we reinforcement
11
Example of Beam without web steel
12
Region where web reinforcement is required
  • When the applied shear force Vu is greater than
    the shear strength of the beam, web reinforcement
    is provided till the shear strength of ?Vc/2.
  • The minimum web reinforcement must be provided
    till the above cited region

13
(No Transcript)
14
(No Transcript)
15
(No Transcript)
16
(No Transcript)
17
(No Transcript)
18
Assignment
  • A rectangular simple beam 12in x18in having a
    span of 20 ft is subjected to service live load
    of 1.5k/ft and superimposed dead load of 1 k/ft.
    Design the web reinforcement of the beam if
    fc3000 psi
  • Draw the cross section of the beam

19
(No Transcript)
Write a Comment
User Comments (0)
About PowerShow.com