CANENA Advisory Group on Horizontal Reference Standards - PowerPoint PPT Presentation

1 / 8
About This Presentation
Title:

CANENA Advisory Group on Horizontal Reference Standards

Description:

59 51 Electric Irons (Trinational or IEC) 59 52 Blenders (Trinational or IEC) ... 59 58 Electric Clothes Dryers (Binational) 2158 C22.2 # 112 X X ACE ... – PowerPoint PPT presentation

Number of Views:81
Avg rating:3.0/5.0
Slides: 9
Provided by: geneec
Category:

less

Transcript and Presenter's Notes

Title: CANENA Advisory Group on Horizontal Reference Standards


1
CANENA Advisory Group onHorizontal Reference
Standards
Status Report
Mexico City February 21, 2001
2
Background
  • Issues
  • Common problems faced by THCs in harmonizing
    standards
  • Lack of mechanism for sharing common problems and
    creative solutions
  • Objectives
  • Establish a mechanism to address one common issue
    faced by THCs, polymeric component material

CAG Horizontal Reference Standards
3
Report of Meeting
  • November 10, 2000
  • Initial objectives
  • Develop a means to attract affected THCs
  • Develop an approach for THC input to CAG
  • Initial Scope
  • UL 746 Series, UL 94, CSA C22.2 No.017
  • Action items
  • Identify ongoing projects that utilize these
    standards.
  • Develop a template for THC reporting to CAG

CAG Horizontal Reference Standards
4
CANENA
Summary Report of Referenced Standards
Makes Reference
THC Project Products UL
CSA Standard ANCE Standard CSA 17 UL 94 UL
746 02 17 Motors and Generators (Hazardous
Locations) 674, 1248 C22.2 No. 145 NMX-J-283 02 1
8 Motors and Generators(for cert and/or
recognition) 1004 C22.2 No. 100 X X C 02 21 Impe
dance Protected Motors 2111 C22.2 No.
77 NOM-074 A 15C 12 Coated Electrical
Sleeving 1441 C22.2 198.3 X B 15C 13 Extruded
Insulated Tubing 224 C22.2 198.1 17B 78 Enclose
d Switches 98 C22.2 4 NMX-J-162 X BCD 17B 83 Ma
gnetic Controllers 508 X ABC 17B/23E 22 Molded
Case Circuit Breakers M.C. Switches 489 C22.2
5, 5.1, 5.2 NMX-J-266 X ABCD 17B/23E 91 Arc
Fault Circuit Interruptors 1699 C22.2
1699 C 17BD/22G/4 5 Control Circuit
Devices 508 C 22.2 14 X 17BD/22G/4 79 General
Rules 508 C22.2 14 X 17BD/22G/4 81 Motor
Control Centers 845 C22.2 14 NMX-J-353 X X ABC 1
7BD/22G/4 82 Medium Voltage Motor
Controllers 347 C22.2 14 X X ABCD 17D 23 Panelb
oards 67 C22.2 29 NMX-J-118 X ACD 17D 24 Switchb
oards 891 C22.2 244 NMX-J-118 Part
2 17D 26 Busways 857 C22.2 27 NMX-J-148 20AB 1
Cord Sets and Power Supply Cords 817 C22.2
21 None X 20AB/55 3 Flexible Cords 62 C22.2
49 NMX-J-436 20AB/55 25 Thermoplastic and
Thermoset Wires 83,44 C22.2 75, C22.2 38 NMX
J-010 23A 15 NMPT Non-metallic Mechanical
Protection Tubing 1696 C22.2 227.3 23A 16 ENT-
Electrical Nonmetallic Tubing 1653 C22.2
227.1 X X B 23A 27 EMT - Electrical Metallic
Tubing 797, 514 C22.2 18, 83 NOM-210 X A 23A 28
Nonmetallic Cable Tray 568 C22.2
126.2 C 23A 29 Electrical Rigid Metal
Conduit 6, 514 C22.2 18, 45, G164 NMX-B-208 X A
23A 30 Conduit Fittings 514B C22.2 18.3 NMX - J
- 017 X X AB 23A 31 IMC - Electrical
Intermediate Metal Conduit 1242, 514 C22.2 (new
standard) NOM-209 A 23A 64 Metal Cable
Tray C22.2 126 23A 74 RTRC-Reinforced
Thermosetting Resin Conduit 1684 C22.2
211.3 23A 75 LFNC - Liquidtight Flexible
Nonmetallic Conduit 1660 C22.2 227.2 X 23B 9 Me
tallic and Nonmetallic Outlet Boxes 514A,
514C C22.2 No. 18.1 (metal), NMX-J-023 X AB
CAG Horizontal Reference Standards
5
CANENA Summary Report of Referenced
Standards, cont.
Makes
Reference THC Project
Products UL CSA Standard ANCE Standard CSA 17
UL 94 UL 746 23BC 32 General Use
Couplers 60320 C22.2 182.3 X AC 23BC 33 Lamph
olders 496, 542 C22.2 43, 74 NMX-J-325 X X A 23
BC 34 Nightlights 1786 C22.2 12M X C 23BC 35
Flush Device Cover Wallplates 514D C22.2
42.1 X X ABC 23BC 36 Electromechanical Gen'l
Use 20 C22.2 111 23BC 41 Dimming
Products/Binat-US-Can 1472 C22.2 No.
184 X X BC 23E 42 Ground Fault Circuit
Interupters 943 C22.2 144 X ABC 23H 14 Pin/Sl
eeve Plug Receptacles Connectors 1682 C22.2
182.1 X ABCD 32 87 Fuseholders 512 C22.2
39 32B 43 Fuses 248 C22.2 Nos. 59,
-106 NMX-J-009/248 34 46 Lamp Ballasts--Safety
Standard 935, 1029 C22.2, 74 X X ABCD 34 49 Lu
minaires Used in Non-hazardous 1598 C22.2, No.
250.0-00 X X 59 51 Electric Irons
(Trinational or IEC) 59 52 Blenders (Trinational
or IEC) 59 53 Dishwashers (Trinational) 749 C22.2
167-95 X X ABCE 59 54 Dishwashers
(Binational) 749 C22.2 167-95 59 55 Gas Clothes
Dryers (Trinational) CSA CGA 1-7.1 59 56 Gas
Clothes Dryers (Binational) CSA CGA
1-7.1 59 57 Coffeemakers (Trinational or
IEC) 59 58 Electric Clothes Dryers
(Binational) 2158 C22.2 112 X X ACE 59 59 Ref
rigerators and Freezers (Binational) 250 C22.2
63 NMX-J-411 X X AC 59 60 Gas Ranges
(Trinational) CSA CGA 1.1 59 61 Clotheswashers
(Trinational) 2157 C22.2 169 NMX-J337 X X ABCDE
59 62 Refrigerators and Freezers (Tinational or
IEC) 250 C22.2 63 NMX-J-411 X X 59 63 Electric
Clothes Dryers (Trinational) 2158 C22.2
112-94 X X 61D 88 Unitary Air Conditioners
Heat Pumps 1995 C22.2 236 X X ABC 70/31 85 Enc
losures-Non-Hazardous Locations 50 C 22.2
94 NMX-J-235 Pt. 1 X C 99 90 Electrical
Connectors 486 AB 487 C22.2 Nos. 65, 188, 41
NMX-J-170,383,395,
CAG Horizontal Reference Standards
6
Next Steps
  • THC and THSC Chairs determine if CAG scope is
    applicable to your work program
  • THC/THSC prepare input from Work Program for
    CAG review (template provided)
  • If THC/THSC has developed a resolution - Share
    method with CAG (template provided)

CAG Horizontal Reference Standards
7
Expected Results
  • Compare and classify common methods of reference
  • Review THC/THSC prepared resolutions
  • Recommend best practice for treatment of common
    methods of reference
  • Recommend a methodology for addressing scopes of
    other reference standards in CANENA work programs
  • CAG Horizontal Reference
    Standards

8
Contact Information
Tim McNeive Thomas Betts
tim_mcneive_at_tnb.com Gene Eckhart NEMA
gen_eckhart_at_nema.org
CAG Horizontal Reference Standards
Write a Comment
User Comments (0)
About PowerShow.com