IMPLICATIONS FOR FALSE POSITIVE ROTATIONAL SPECT RSPECT STUDIES BEING CAUSED BY POSTSTRESS CHANGES I - PowerPoint PPT Presentation

1 / 29
About This Presentation
Title:

IMPLICATIONS FOR FALSE POSITIVE ROTATIONAL SPECT RSPECT STUDIES BEING CAUSED BY POSTSTRESS CHANGES I

Description:

T.P. Bublitz, D.L. Kirch*, J.E. Koss, P.P. Steele. Nuclear Cardiology Research. Western Cardiology Associates, PC. Englewood, Colorado ... – PowerPoint PPT presentation

Number of Views:20
Avg rating:3.0/5.0
Slides: 30
Provided by: lynnk2
Category:

less

Transcript and Presenter's Notes

Title: IMPLICATIONS FOR FALSE POSITIVE ROTATIONAL SPECT RSPECT STUDIES BEING CAUSED BY POSTSTRESS CHANGES I


1
IMPLICATIONS FOR FALSE POSITIVE ROTATIONAL SPECT
(RSPECT) STUDIES BEING CAUSED BY POST-STRESS
CHANGES IN CARDIAC VOLUME
  • T.P. Bublitz, D.L. Kirch, J.E. Koss, P.P. Steele
  • Nuclear Cardiology Research
  • Western Cardiology Associates, PC
  • Englewood, Colorado

2
PREVIOUS INDICATIONS THAT CARDIAC CHAMBER SIZE
CHANGES COULD BE A PROBLEM
  • Literature describes dramatic shape and volume
    changes during and following exercise and change
    of position
  • Occurrence of unexplainable false positive
    myocardial perfusion studies (specificity in the
    70-80 range)
  • Numerous attempts to identify and correct for
    sources of artifacts in RSPECT studies have
    proven inconclusive
  • Visual inspection of cine playback of RSPECT
    images
  • Ability of NRSPECT to monitor cardiac chamber
    volume changes over a 20-30 min period following
    stress

3
METHODOLOGY APPLIED TO SEQUENTIALLY MONITOR
CARDIAC VOLUME CHANGES
  • MULTI-PINHOLE NRSPECT IS UNIQUELEY SUITED FOR
    SERIAL MEASUREMENTS
  • EXCELLENT STATISTICS PERMIT VOLUME COMPUTATIONS
    TO BE MADE IN THREE MINUTE INTERVALS
  • MIDLINE OR CENTER WALL TRACKING USED TO COMPUTE
    VOLUMES
  • VISUAL INSPECTION USED TO CORROBORATE THE
    MAGNITUDE AND DIRECTION OF THE COMPUTED CHANGES
  • CHAMBER SHAPE CHANGES ARE VISUALLY APPRECIATED

4
SIMULTANEOUS DUAL-ISOTOPE (TL-201/TC99m)
MYOCARDIAL PERFUSION IMAGING PROTOCOL
  • SETUP IV AND INJECT 6.0 mCi OF Tc AGENT
  • PATIENT DRINKS 8-16 oz OF CLEAR LIQUID DURING 10
    min WAIT PRIOR TO EKG HOOK-UP FOR STRESS TEST
  • INJECTION OF 4.0 mCi OF Tl-201 OCCURS 1-2 min
    PRIOR TO CESSATION OF STRESS MANEUVRE
  • GATED, SIMULTANEOUS DUAL-ISOTOPE IMAGING IS
    PERFORMED IMMEDIATELY FOLLOWING COOL DOWN
  • LIST-MODE DATA ACQUISITION TAKES ABOUT 20 MINUTES
    AND RESULTS IN 3 MILLION COUNTS PER VIEW
  • TOTAL DURATION OF TEST IS lt 90 min

5
MULTI-PINHOLE TOMOGRAPHIC RECONSTRUCTIONS
SHORT AXIS RESTING IMAGES Tc-99m
SHORT AXIS STRESS IMAGES Tl-201
LONG AXIS RESTING IMAGES
LONG AXIS STRESS IMAGES
6
CENTER WALL TRACKING PERFORMED ON 8 SHORT AXIS
SLICES FROM APEX TO BASE
CCP CURVES DEVELOPED AT 60 POINTS THROUGH 360o.
SEARCH FOR MAXIMUM VALUE AVERAGED WITH TWO
NEAREST RADIAL NEIGHBORS
APEX
BASE
7
CIRCUMFERENTIAL COUNT PROFILE CURVES

STRESS
REST
STRESS-REST DIFFERENCE
8
VOLUME IMAGES UNGATED (TOP) GATED (BOTTOM)
RESTING (LATE) VOLUME IMAGES 72cc
STRESS (EARLY) VOLUME IMAGES 77 cc
MID VOL 73cc
9
ACUTELY DILATED VOLUME (77 cc TO 72 cc) WITH
INFERIOR LATERAL SHAPE CHANGES
10
ACUTELY DIMINISHED VOLUME (113 cc TO 130 cc) WITH
SUPERIOR LATERAL SHAPE CHANGES
11
NO VOLUME CHANGES (50 cc TO 52 cc) AND NO
SIGNIFICANT SHAPE CHANGES
12
ACUTELY DILATED VOLUME (135 cc TO 126 cc) WITH
SUPERIOR SEPTAL SHAPE CHANGES
13
NEGLIGIBLE VOLUME CHANGES (110 cc TO 111cc) WITH
REDISTRIBUTATIVE SIZE CHANGES
14
ACUTE VOLUME DILATION (102 cc TO 96 cc) WITH
INFERIOR SHAPE CHANGES
15
(No Transcript)
16
CORRELATION BETWEEN POST STRESS VOLUME CHANGES
AND RATE-PRESSURE PRODUCT
17
CORRELATION BETWEEN POST STRESS VOLUME CHANGES
AND AGE (MEN AND WOMEN COMBINED)
18
CORRELATION BETWEEN POST STRESS VOLUME CHANGES
AND AGE (MEN ONLY)
19
CORRELATION BETWEEN POST STRESS VOLUME CHANGES
AND AGE (WOMEN ONLY)
20
CORRELATION BETWEEN POST STRESS VOLUME CHANGES
AND BODY MASS INDEX
OBESE
21
CONCLUSIONS FROM ANALYSIS OF 818 DUAL-ISOTOPE
GATED PERFUSION STUDIES
  • THE MEAN VALUE OF LV VOLUME CHANGES IS 4.5
  • MAJORITY OF PATIENTS (70) SHOW ACUTE DILATION
    FOLLOWING EXERCISE AND RECLINE FOR IMAGING
  • 23.3 OF PATIENTS SHOW DILATION GREATER THE 10
  • 3 OF PATIENTS SHOW DIMINATION GREATER THAN -10
  • IN 13 OF PATIENTS SHOWING VOLUME CHANGES gt10
    RESOLUTION TO LESS THAN 5 OCCURS BY THE 10 min
    MID-POINT
  • SIGNIFICANT VENTRICULAR SHAPE CHANGES CAN OCCUR
    WITH LITTLE CHANGE IN THE COMPUTED VOLUME OF THE
    VENTRICLE
  • WE HAVE NOT FOUND ANY PRE- OR POST-TEST CORRELATE
    THAT PREDICTS THE MAGNITUDE OF THESE CHANGES
  • SEQUENTIAL STUDIES ON THE SAME PATIENT ARE
    UNPREDICTABLE

22
Study Comparison
23
CINE DISPLAY OF TWO SUCCESSIVE RESTING IMAGES
ACQUIRED BACK-TO-BACK
RESTING DATA SET
PSEUDO STRESS DATA SET
24
(No Transcript)
25
(No Transcript)
26
(No Transcript)
27
(No Transcript)
28
CINE DISPLAY OF FRAMES 31 AND 32
These are the transitional frames acquired by
detector 1 and detector 2
RESTING STUDY PSEUDO STRESS
STUDY
29
(No Transcript)
Write a Comment
User Comments (0)
About PowerShow.com