Michael Drew Regional Specification Engineer michael.drew@sylvania.com (865) 548-6382 - PowerPoint PPT Presentation

View by Category
About This Presentation
Title:

Michael Drew Regional Specification Engineer michael.drew@sylvania.com (865) 548-6382

Description:

Michael Drew Regional Specification Engineer michael'drewsylvania'com 865 5486382 – PowerPoint PPT presentation

Number of Views:198
Avg rating:3.0/5.0
Slides: 79
Provided by: ande153
Learn more at: http://www.sashto.org
Category:

less

Write a Comment
User Comments (0)
Transcript and Presenter's Notes

Title: Michael Drew Regional Specification Engineer michael.drew@sylvania.com (865) 548-6382


1
Michael Drew Regional Specification
Engineer michael.drew_at_sylvania.com (865)
548-6382
2
Advances in Roadway and Street Lighting-LED and
Other Advanced Technologies
  • Recent Developments of Familiar Sources
  • Metal Halide
  • High Pressure Sodium
  • Fluorescent
  • LED Technology Overview
  • Technology and how to select the right solution
  • The Latest in Fixture Design
  • What are our Fixture Partners Developing

3
Energy Independence and Security Act of 2007
  • Sec. 324 Metal Halide Lamp Fixtures (page 261)
  • Covers
  • Metal Halide lamp fixtures operated with lamps
    150 watts but 500 watts shall contain
  • A pulse-start metal halide ballast with a minimum
    ballast efficiency of 88
  • A magnetic probe-start ballast with a minimum
    ballast efficiency of 94
  • A non pulse-start electronic ballast with
  • A minimum ballast efficiency of 92 for wattages
    gt 250 watts
  • A minimum ballast efficiency of 90 for wattages
    250 watts
  • New fixtures only does not effect replacement
    lamps or ballasts

4
  • METALARC
  • PULSE START

5
Pulse Start vs. Probe Start
  • Traditional MH lamps use probe-start technology
  • Ballast provides low starting voltage, between
    400V 800V, depending on wattage
  • Discharge is created across small gap between the
    starting electrode (probe) and the operating
    electrode
  • As temperature and pressure grow, gas ionizes,
    arc jumps the large gap to the opposing electrode
  • Once started, a bi-metal switch, removes the
    starting probe electrode from the circuit
  • Pulse Start lamps do not require a starting probe
  • A high voltage ignitor works with the ballast to
    deliver a series of high-voltage pulses,
    typically 3,000 to 5,000 volts (3-5kV)
  • The initial discharge is created between the two
    operating electrodes
  • Arc tube fill pressure can be set higher
    potential for longer life and better color
    consistency
  • Tungsten deposits from thin probe wire are
    eliminated better lumen maintenance
  • Lamp warm-up time is reduced
  • Cold starting is improved down to -40C

6
METALARC PULSE START Benefits
  • Improved lumen maintenance
  • Reduced color shift
  • More light output over life
  • Faster re-strike time
  • Potentially longer life

7
METALARC Pulse Start Family
  • MP320/350/PS/BU-ONLY (Clear Coated)
  • MP350/400/PS/BU-ONLY (Clear Coated)
  • M400/PS/U NEW!
  • M400/PS/U/BT28 NEW!
  • MS400/PS/BT28 BU-ONLY BD-ONLY
  • MS400/PS/BU-ONLY (Clear Coated)
  • MS750/PS/BU-HOR (Clear Coated)
  • M1000/PS/U/BT37 NEW!

? All existing low wattage metal halide lamps ?
150W
  • M175/PS/U NEW!
  • MS175/PS/MED/BU-ONLY (Clear Coated)
  • MS175/PS/BU-ONLY (Clear Coated)
  • MS200/PS/BU-ONLY/ET23.5
  • MS200/PS/BU-ONLY (Clear Coated)
  • M250/PS/U NEW!
  • MS250/PS/BU-ONLY (Clear Coated)
  • MP250/PS/BU-ONLY (Clear Coated)
  • MS320/PS/BU-HOR (Clear Coated)

8
Ceramic vs. Quartz
  • MH lamps can use either quartz or ceramic arc
    tubes
  • Quartz arc tubes can be probe start or pulse
    start
  • Ceramic arc tubes are only pulse start
  • Ceramic material can run hotter and at higher
    pressures than quartz
  • Creates a more efficient light source higher
    lumens per watt (LPW)
  • Smaller arc tube bodies can be used, so
  • Arc tube temperatures are more uniform which
    improves color rendering and color consistency
  • Arc gap is smaller so light source is more
    focusable

9
Transition to Advanced Ceramic Technology
All OSI types have been converted to POWERBALL
10
The POWERBALL Difference
  • POWERBALL
  • Consistent wall thickness
  • Optimal end-bell geometry
  • Uniform AT temperatures
  • Full MH Evaporation
  • Cylindrical Arc Tube
  • Varying wall thickness
  • Square end-bell geometry
  • Heat loss
  • MH Condensation

Cylindrical
POWERBALL
11
The POWERBALL Difference
  • POWERBALL Superior performance
  • Longer life
  • Color consistency
  • Highest CRIs (very good R9)
  • Cylindrical Arc Tube
  • Shortened life (corrosion)
  • Color shift (position life)
  • Good CRIs (lower R9)

Cylindrical
POWERBALL
12
POWERBALL Resistance to Corrosion
13
LUMALUX/PLUSECO
Non-Cycling High Pressure Sodium Vapor

14
LUMALUX PLUS /ECO OVERVIEW
  • 40,000 Hour Rated Life
  • Better Lumen Maintenance
  • Non-Cycling
  • Reduced service maintenance costs -- no wasted
    trips
  • Environmentally Friendlier
  • Pass Federal TCLP
  • 90 less Hg than standard lamps
  • Lead-free, welded base
  • Reduced base failures

Based on NEMA LL Series Standards 1000W,
70W/MED, 100W/MED Lamps are not ECO
15
LUMALUX PLUS / ECO
  • AN EASY CHANGE!!
  • Initial and mean lumens equal to or higher than
    standard Lumalux (efficacy - up to 125 LPW)
  • Maintains same ballasting requirements
  • Conforms to ANSI designation direct replacement

16
LUMALUX PLUS /ECO
ECOLOGIC PRODUCT
  • WELDED BASE
  • Reduces base failures
  • No lead solder reaction
  • Operates at higher temperatures than standard
    Lumalux (maximum temperature up to 250C)

Excluding 1000W lamps
17
What makes LU PLUS non-cycling?
  • High Pressure Rare Fill gas to lower arc tube
    wall operating temperature
  • Xe-Ar Fill vs. Ar only (std)
  • Patented material BSY2 (Barium Strontium
    Yttrate)
  • Emissive coating on electrode
  • 90 Less mercury content than that of standard
    Lumalux
  • Ignition Aide required

18
LUMALUX PLUS /ECO
  • SYSTEM MAINTENANCE ADVANTAGES
  • Eliminates trouble-shooting field visits for
    cycling lamps
  • Eliminates throwing away good lamps
  • Reduces unnecessary component change out (i.e.
    photo cell)

19
HISTORY OF LUMALUX PLUS
  • SYLVANIA LU/PLUS
  • 11 years field history
  • Out at end of life
  • Easiest to locate at end of life
  • Proven design
  • 80 lumens prior to failure

20
LUMALUX PLUS /ECO Advantages over Standard
LUMALUX
  • Lamps out get replaced quicker than cycling lamps
  • Lamps outages are easier to locate
  • Fewer failures
  • Extended group relamping cycle if employed
  • Cycling lamp puts more stress on the ballast than
    a lamp out
  • For a cycling lamp 5 minutes on / 1 minute off,
    ignitor will be energized for 110minutes per day
  • Longer life means huge dollar savings
  • Less mercury in lamp
  • Restructured warranty

21
ICETRON Systems
Inductively Coupled Electrodeless ElecTRONic
System

22
ICETRON Operating Principle
23
ICETRON Systems
  • 100,000 hour system life
  • White Light
  • 3500K, 4100, and 5000K
  • 80 CRI
  • Starting as low as -40C (-25C for 70W)
  • ECO - TCLP compliant
  • Instant On/Instant Re-start
  • Universal Voltage 120-277V
  • Remote mounting (up to 66)
  • Amalgam technology
  • Lead Free Glass

150W lamp 150W ballast 12,000 Lumens
100W/100W 8,000 Lumens 100W/150W 11,000 Lumens
70W/100 6,500 Lumens 1.05 Ballast Factor
40 watt, 200 watt and 250 watt Soon to be Released
24
ICETRON Reflector
  • Lots of light. Where you want it. For a long
    time
  • Sylvania Icetron Reflector
  • Incorporates internal reflector to direct and
    spread the light
  • Long 100,000 hour life
  • White Light 4100K
  • Consistent color 80 CRI
  • Starting temperatures as low as -40 F
  • Amalgam technology
  • TCLP complaint
  • High output electronic system
  • Universal voltage ballast
  • Ballast remote mounting possible

25
ICETRON Reflector (Cont.)
26
Lumens
27
System Mortality
  • The ICETRON QUICKTRONIC systems are designed to
    have an average rated life of 100,000 hours at a
    maximum ballast case temperature of 158F (70C)
    for the 150W ballast (or 149F/ 65C for the 100W
    ballast).
  • After 100,000 hours 50 of the ballasts will be
    surviving. (At 60,000 hours, 10 failures are
    expected.) However, the luminous flux of the
    ICETRON lamp is expected to have depreciated
    after 60,000 hours to no less than 70 (65 for
    100W lamp) of the initial rated lumens.

28
Warranty
29
Jeff TeRoller LED Applications Specialist
jeff.teroller_at_sylvania.com (616) 717-1888
30
LED Street, Pedestrian, and Parking Area Lighting
Solutions
LED Technology Overview
31
OSRAM SYLVANIA Over 100 Years
32
OSRAM Opto White Applications
33
Global LED Technology Leadership
  • OSRAM SYLVANIA is one of the two largest LED
    manufacturers in the world
  • OSRAM SYLVANIA is the largest lighting company in
    the US
  • OSRAM SYLVANIA holds over 4,000 patents in LED
    technology, with 170 of those patents in white
    LED technology
  • OSRAM SYLVANIA has capacity to ship over 10
    Billion LED chips each year
  • Yokohama
  • - Sales Japan
  • Marketing
  • Application Center
  • Northville
  • Sales Marketing NA East
  • - Application Center
  • Regensburg
  • - Headquarter
  • - Sales HQ
  • LED
  • Infrared - Conceptual Engineering
  • - Front End Production

Santa Clara - Headquarter NA - Sales Marketing
NA West
  • Hong Kong Shanghai
  • Sales Asia North
  • Marketing
  • Application Center
  • Penang
  • Plant
  • OLED Display
  • - Regional Customer Service
  • - Sales Asia South









34
New York Alexander Hamilton Custom House
OSRAM SYLVANIA Products At Work.
METALARC POWERBALL ceramic metal halide lamps,
LEDs
35
Boston Bunker Hill Monument
OSRAM SYLVANIA Products At Work.
METALARC POWERBALL ceramic metal halide lamps
36
Washington, D.C. Jefferson Memorial
OSRAM SYLVANIA Products At Work.
METALARC POWERBALL ceramic metal halide lamps,
LEDs
37
Philadelphia Phillies ballpark sign
OSRAM SYLVANIA Products At Work.
ICETRON induction lamps
38
China Beijing, National Stadium
OSRAM SYLVANIA Products At Work.
NEU. Aus Prisma, leider keine genaue Beschreibung
der Produkte
  • 4,000 OSRAM FH28HE/60

39
China Beijing, Aquatic Center
OSRAM SYLVANIA Products At Work.
Neu aus Prisma
  • 350 HQI-TS

40
Miami Bank of America Tower at International
Place
OSRAM SYLVANIA Products At Work.
PENTRON T5 and OCTRON T8 fluorescent lamps, LEDs
41
Chicago Riverbend Tower
OSRAM SYLVANIA Products At Work.
LINEARlight Flex LED system
42
Detroit 2010 Ford Mustang
OSRAM SYLVANIA Products At Work.
XENON HID headlamps, Joule LED systems
tailights, TOPLED LED interior lights
43
Russia Moscow, Pedestrian Bridge over the Moskva
OSRAM SYLVANIA Products At Work.
HQI-TS, HQI-E and HCI-T metal halide lamps and
LEDs
Photo Svetoservice, Moscow
44
Germany Hamburg, Cruise Ship AIDAdiva
OSRAM SYLVANIA Products At Work.
OSRAM DULUX EL LONGLIFE, LEDs
Source AIDAdiva
45
Turkey Istanbul, Blue Mosque
OSRAM SYLVANIA Products At Work.
OSRAM HQI-T, NAV-T lamps
46
Argentina Buenos Aires, Obelisk
OSRAM SYLVANIA Products At Work.
OSRAM POWERSTAR HQI-T2000W/N
47
Spain Barcelona, Hotel Prestige
OSRAM SYLVANIA Products At Work.
LINEARlight Colormix
48
Norway Oslo, Opera House
OSRAM SYLVANIA Products At Work.
1,250 OSRAM LINEARlight DRAGON LED
49
Germany Hamburg, Hotel Atlantic
OSRAM SYLVANIA Products At Work.
24 LINEARlight- DRAGON Colormix
50
China Beijing, Airport
OSRAM SYLVANIA Products At Work.
NEU
42,000 OSRAM DULUX, 47,000 OSRAM LUMILUX T8/T5,
63,600 POWERBALL HCI
51
Germany Frankfurt, Radisson Hotel
OSRAM SYLVANIA Products At Work.
  • 5.000 DECOSTAR 51 ENERGY SAVER, HALOGEN ENERGY
    SAVER CLASSIC A or B

52
Croatia Zagreb, Homeland Bridge
OSRAM SYLVANIA Products At Work.
  • LINEARlight Colormix LED

53
Customer Education LED Fundamentals
Ohms Law IV/R
Ref http//electronics.howstuffworks.com/led2.ht
m
54
The Next .COM Industry?
  • It only take a soldering iron and some LEDs
    right?
  • Some banks see this as a short term profit
    opportunity
  • Can produce brightly lit LED panels or strips
    installed into street lights
  • Does not produce a quality product long term
  • Will they be around to support the claimed
    warranty?
  • How do you protect yourself and your
    organization?

55
Simple Way to Protect Yourself
  • Know who you are considering buying from
  • Start with Standardized Testing before investing
    time and effort
  • LM-79
  • LM-80
  • UL Listing
  • Utilize simple process to prove out performance
    (WLLC)
  • Warranty and ability to service warranty
  • Make a career building decision

56
LED Life Projection - Thermal Modeling
  • Long life is a significant benefit of LED
    systems
  • 50,000 hours life conservatively
  • Some competitors claiming 100,000 to 250,000
    hours life without experience or data
  • LED may not be the life limiting sub-system
    power supply? connectors? other?

57
LED Testing Standards
  • L70 70 Lumen Maintenance
  • INDEPENDENT LM-79 Basic system performance
    including light output, total wattage,
    temperature, and more
  • INDEPENDENT LM-80 Long term lumen maintenance
    (6,000 hour test)
  • UL Listing
  • Energy Star?
  • Example LM-80

58
Eliminate Confusion Wattage, Light, Life,
Current
  • Less marketing and more substance..buyer beware
  • Total Lumen Output
  • Lumens / Watt (efficacy or efficiency)
  • Extreme Life Ratings
  • Generic energy savings ratings (saves about
    50)
  • Patented heat management system
  • Engineered optics
  • Looks brighter, lasts longer, etc.
  • 4 Keys (WLLC)
  • WATTAGE - Total wattage the system is pulling
  • LIGHT - Amount of light delivered to the surface
    (street, sidewalk, etc)
  • LIFE - Temperature the LED is running at (which
    helps determine life)
  • CURRENT What current the LED is being driven at
    (which helps determine life)

59
LED Post Top Performance no small difference
60
LED Post Top Performance no small difference
61
Introducing the OSRAM SYLVANIA LED Post Top
Retrofit
62
LED Post Top Retrofit Benefits
  • Mercury Free
  • Consumes less than 40 watts
  • Environmentally friendly energy savings and
    dont have to discard existing fixtures
  • Easy to install in as little as 15 minutes
  • True IES Type III and Type V photometrics
  • Recommended for applications up to 150w HPS or
    250w MH (based on customer feedback please test
    4 to confirm performance in your application
    IES files available)
  • 12 Year average life
  • Exceptional light management dark skies
    friendly

63
LED Post Top Retrofit Benefits
  • No cycling or restrike delays
  • Universal voltage power supply
  • Ultra High Efficiency 5700K OSRAM SYLVANIA LEDs
  • with warmer color temperatures available
  • High performance thermal management
  • Short, open, and thermal overload protected
  • Extreme temperature tested
  • UL Listed
  • Full 5 year warranty
  • No risk 60 day return policy test 4, return
    for a full refund
  • Works in a wide variety of fixture types

Just a few of the many fixture types easily
retrofitted
64
Actual Benchmark Comparison
  • OSRAM SYLVANIA
  • Wattage 40w
  • Light 20 above target
  • Life 50,000 hours conservatively
  • Current 200mA
  • Total Energy Cost over life 187.49

Competitor XYZ Wattage 87.0w Light 15 below
target Life 50,000 hours (estimate)
Current unknown Total Energy Cost over life
438.48
OSRAM SYLVANIA solution saves 250.99 in energy
alone over competitor LED solution and delivers
superior light!
65
Example Installation of Post-Top LED Retrofit Kit
  • Test installations at more than 15 cities
  • Sample Installation - Pineland Business Park in
    New Gloucester, Maine
  • 40W LED solution replacing 175W and 250W MH lamps
  • Precise optical control allows
  • reduction in light pollution

66
Generation II LED Post Top Retrofit
  • Gen II
  • New higher output, lower wattage, smaller, warmer
    color temperature unit
  • Available in Type III and Type V distribution
    patterns
  • Uses less than 40 watts
  • Fits a wide variety of fixture types
  • Can either mount with a top center post, or using
    4 brackets for globe top mounting (comes with
    both types of hardware already installed)
  • Dimensions 11 x 9.5 x 6.5

Center / Finial Top Mounting Bracket
Adjustable Globe Top Mounting Brackets
67
Photometric Upgrade Gen I to Gen II
Generation I
Generation II
175w Metal Halide
68
6 LED Retrofit Introduction
  • 25 more light output and 1.5x area coverage
  • lt52 W power replacing up to 175W HID lamps
  • 50,000 hours life time (70 lumen maintenance)
  • Ambient temperature -22F 104F (fixture
    outside)
  • Small outer diameter 6.5 inch
  • 120V 277V AC input voltage
  • Photometric Patterns
  • TYPE V Medium
  • TYPE III Medium
  • Bare LED Kit
  • Color Temperatures 4900K 5700K
  • Mounting flexibility bottom, top, side
  • UL recognized and FCC compliant
  • Engineering Samples
  • Aug 2009 (Type V Medium)
  • Oct 2009 (Type III Medium)
  • Available Oct 2009 (Type V Medium)
  • Dec 2009 (Type III Medium)

Top mounting bracket
LED light Module mounted on heat sink
Cable
Surge Protector
Power Supply
69
6-inch LED Retrofit Light Patterns (in
foot-candle)
Type V Medium
Type III Medium
Mounting Height 10. Each box is one mounting
height
Mounting Height 10. Each box is one mounting
height
Above optical simulation Data does NOT include
light loss from fixture cover.
70
Mounting 6 LED Retrofit from Bottom
Metal conduit
Base Disk
71
Mounting 6 LED Retrofit from Side
Side Brackets
Cable Conduit
72
Mounting 6 LED Retrofit from Top
Top Bracket
Metal Conduit
73
Thank you for your attention.
Jeff TeRoller, LED Applications
Specialist jeff.teroller_at_sylvania.com (616)
717-1888
74
Ralph Mosher Manager, Business Development -
Innovation ralph.mosher_at_sylvania.com (978)
239-7944
75
SSL Street Area Lighting OEMs
  • cobraLux by LED folio
  • Low wattage Street Light utilizing 9 distinct LED
    modules
  • Heat Sink is integrated into the fixture head
  • Low Glare Optics
  • 4 LED wattages available to replace up to 250
    watt HID fixtures

Both of these products were featured in our booth
at Lightfair 2009
  • Induction Cobra Head by 1st Source
  • Fixture is designed specifically for ICETRON
  • 70, or 100 watt ICETRON lamps up to 11,000 lumens
  • 1st Source specializes in replacing HID systems
    with induction

76
SSL Street Area Lighting OEMs
  • Polera LED/HID Hybrid by Visionaire
  • LED and HPS - LED and Induction - LED and LPS
  • Light sources operate at different times of the
    night
  • LED during first half (commercial hours) and
    second source for the remainder
  • Longer life from fixture
  • Dark Sky Compliant
  • Endorsed by International Astronomers
    Association

Featured in our booth at Lightfair 2009
77
SSL Street Area Lighting
LED Street Lighting Projects
78
Traffic Control Signage
A Chicago based OEM
Lamp Type ICETRON Fixture Model Municipality
TCS Series
ICETRON Lamps feature a 100,000 hr Life
About PowerShow.com