Scintillator (semi)DHCAL? - PowerPoint PPT Presentation

About This Presentation
Title:

Scintillator (semi)DHCAL?

Description:

Cell sizes are necessarily 6-12 cm2. Can one control energy resolution for ... Carlo single particle resolutions convoluted in jet resolutions indicate that ... – PowerPoint PPT presentation

Number of Views:33
Avg rating:3.0/5.0
Slides: 20
Provided by: vishnuv1
Learn more at: http://nicadd.niu.edu
Category:

less

Transcript and Presenter's Notes

Title: Scintillator (semi)DHCAL?


1
Scintillator (semi)DHCAL?
  • Vishnu Zutshi
  • for

2
Introduction
  • Can a scintillator (semi)digital calorimeter
    work?
  • Cell sizes are necessarily 6-12 cm2
  • Can one control energy resolution for these sizes
    (no strong evidence that pattern recognition will
    fail for these sizes)?
  • SD detector used for these studies

3
Sampling Weights
  • Determined from 10 GeV charged pions
  • Minimize
  • (1/N) S (E0 aiLi)2
    where
  • E0 is the incident energy
  • ai is the weight for layer i
  • Li is the energy/number of hits in lyr i
  • For simplicity i2 considered here

4
Energy Resolution
single threshold
5
ZZ Events
6
Simple Jet Reconstruction
  • Pt order stable mc particles (neutrinos are
    ignored)
  • Start with highest pt particle and cluster
    particles within a 0.7 cone
  • Repeat procedure with remaining particles

7
Jet Composition
8
Energy Smearing
  • Fit the sigmas as a function of the incident
    energy
  • Throw a random gaussian
  • Smear the neutral hadron E accordingly
  • Photons are smeared with a 17 term
  • Generated E used for charged hadrons

9
Sanity Check
10
Impact of Neutral Hadrons
11
Jet Energy Resolution
Fitted widths
12
Jet Energy Resolution
rms
13
Jet E/Egen (digital)
14
Jet E/Egen (analog)
15
Single Particle Resolutions
Non-projective geometry single threshold
16
Single Particle Resolutions
Non-projective geometry dual threshold
17
Projective vs Non-projective
18
Jet Energy Resolutions
19
Summary
  • Monte Carlo single particle resolutions
    convoluted in jet resolutions indicate that cells
    of size 9cm2 can be used to measure energy with
    reasonable degree of accuracy in a (semi)digital
    manner
  • Only simple counting was used
Write a Comment
User Comments (0)
About PowerShow.com