Thermal Neutron Activation: - PowerPoint PPT Presentation

1 / 32
About This Presentation
Title:

Thermal Neutron Activation:

Description:

Our Contribution To The War Against Terror. Name: ... Dynamite. 0.3. 18. 61. 19. 2. PETN. 0.3. 19. 63. 16. 2. Nitroglycerine. 0.5. 35. 58. 5. Ammonium Nitrate ... – PowerPoint PPT presentation

Number of Views:134
Avg rating:3.0/5.0
Slides: 33
Provided by: u48
Category:

less

Transcript and Presenter's Notes

Title: Thermal Neutron Activation:


1
Thermal Neutron Activation
  • Our Contribution To The War Against Terror

Name Viliami .T. Takau Supervisors Dr. M.N.
Thompson, Dr. R.P. Rassool
2
Outline of This Talk
  • Current methods of detecting explosives
  • Nuclear techniques
  • TNA technique leads the way
  • Development of an airport explosive
    detection
  • system
  • Immediate future

3
Current Explosive Detection Systems
  • violation of civil liberties, explosives can be
    concealed in unusual configurations
  • trained animals has short attention span,
    mechanical sniffers sensitive only to certain
    explosives
  • non-uniqueness of the signal, human error is a
    huge factor
  • manual search
  • vapour detection
  • X-ray imaging

4
Explosive Composition(wt.) ?(14N)

5
Measuring Nitrogen in Explosives Nuclear methods
  • Photonuclear Reactions
  • 14N ? ? ¹³N n (t 600s)
  • ? ¹³C ß ? 2?

! Problems
2. Inelastic Scattering of Neutrons 14N n
? 14N n ?
14N ?
! Problems
6
Measuring Nitrogen in Explosives Nuclear Methods
  • 3. Thermal Neutron Activation
  • 14N nthermal ? 15N
  • ? 15N
    ? (10.83 MeV)

Way to Go?
NB 10.83 MeV is the highest prompt neutron
capture ?-ray found in nature
hence an excellent signature
of the presence of nitrogen.
7
Q-value for Radiative Capture Reactions
  • Q(n,?) m(AXz) m(1n0) m(A1Xz)
    931MeV/a.m.u
  • Energy available for ?-ray emission is just the
    difference in the binding energies of the target
    and compound nuclei.
  • Q-values are always positive and has a zero
    energy threshold the only energetically
    possible reactions for thermal neutrons and many
    nuclei.

8
(No Transcript)
9
(No Transcript)
10
Capture Cross Section(sc) 14N
11
14N
fn
12
14N
n
13
15N
14
15N
10.8 MeV ? ray
15
15N
16
15N
10.8 MeV ? ray
17
15N
10.8 MeV ? ray
18
15N
10.8 MeV ? ray
19
15N
10.8 MeV ? ray
20
(No Transcript)
21
Development of an Airport Explosive Detection
System
  • Based on the following previous work

Development and investigation of a compact
parcel bomb detector C. Everton, M.N.
Thompson, R.P. Rassool et al
Development and investigation of a total body
protein measuring system D.J.
Borovnicar, M.N. Thompson, D.B Stroud et al
22
(No Transcript)
23
(No Transcript)
24
SNUPA I
Moderator
?-ray Detectors
25
SNUPA I
?-ray Detectors
26
Problems !!!
  • Increasing the cavity size results in a drop in
    the overall flux
  • Increasing the number of neutron sources will
    cause activation in the detector leads to
    pile-up effect
  • ?-ray flux will decrease as a result of the above
  • Plus other problems

27
Modeling larger cavity


28
(No Transcript)
29
(No Transcript)
30
Cross-section of Integrated Thermal Neutron Flux
(scanning region)
No. of Counts
-30
-20
-10
0
10
20
30
Width of Cavity (cm)
31
(No Transcript)
32
(No Transcript)
33
(No Transcript)
34
Immediate Future
  • General Optimisation of the System
  • Signal to background ratio
  • Minimum amount of nitrogen detected
  • Signal processing electronics
  • Pile-up reduction electronic means etc.

35
(No Transcript)
Write a Comment
User Comments (0)
About PowerShow.com