1Welcome To TowerTech Global
2How You Can Enhance Water Efficiency In Close
Circuit Water Cooling Towers?
Heat is a residual product of manufacturing and
machine operation. It can be useful but most
processes need hot machines and final products to
be cooled. In old times, machines were using
chillers to get cool down, but with growing
concern around energy, simple cooling systems are
making a comeback. Manufacturers always try to
find measures to reduce heat gain. In this
article, they will tell you how you can enhance
water efficiency and keep your close circuit
water cooling tower's consumption low.
3Evaporation
Evaporative cooling is important to open circuit
cooling towers. Locating the system in a hot and
windy area will increase water waste. By lowering
the heat load on the cooling tower with the help
of dry or closed circuit system, you can reduce
the wastage of water.
4Blowdown
Blowdown water is a significant process to
promote durability and efficiency of the
equipment as it reduces the solid build ups
inside the system. The frequency of discharge is
generally monitored by measuring cooling water
conductivity. How It Reduces The Water
Consumption? It enhances the quality of feed
water and optimizes the cooling tower process. It
also removes the solids from blowdown water prior
re-circulating it into the system. User can lower
the blowdown volume by automating blowdown based
on conductivity of the circulating water to
sustain maximum solids.
5Blowdown Recycling
- Numerous companies are now collecting blowdown
water for recycling purposes onsite instead of
using portable water. Blowdown water can be used
for - Cleaning
- Wash down
- Toilet flushing
- It can also be reused in cooling circuit once
deionised
6Drift, splash out, overflow
You can enhance the efficiency of your close
circuit water cooling towers by locating the
tower in areas not exposed to excessive heat or
high winds. Drift may pose a public health issue
in some cases. Overflow can occur when a poorly
fitted float valve allows the tower overfill
until water flows straight out the overflow and
into sewer. You can skip overflowing issue by
checking during routine maintenance and by
monitoring water consumption. You can check for
leaks by inspection and performing a mass balance
or direct metering of flows.