Listeria Intervention and Control - PowerPoint PPT Presentation

1 / 34
About This Presentation
Title:

Listeria Intervention and Control

Description:

Prevent the establishment of L. monocytogenes growth in a ... Foot Baths. Spray vs. foam. Heat as a Sanitizer. Flood equip. with 180 F water. Steam sanitize ... – PowerPoint PPT presentation

Number of Views:411
Avg rating:3.0/5.0
Slides: 35
Provided by: LynnK87
Category:

less

Transcript and Presenter's Notes

Title: Listeria Intervention and Control


1
Listeria Intervention and Control
  • Animal Sciences 555.02
  • Lynn Knipe
  • Ohio State University

2
Listeria Control
  • Sanitation
  • Product Formulation
  • Post-Packaging Re-Heating
  • Sampling for Process Control

3
Sanitation
  • Prevent the establishment of L. monocytogenes
    growth in a niche or other sites that can lead
    to contamination of ready-to-eat (RTE) products.

4
Sanitary Design
  • applies to the entire manufacturing unit etc.)
  • focuses on the entire life cycle of the
    manufacturing unit (next 20-30 yrs.)
  • ensures proper efficient cleaning at 3
    levels phys., chem. bio.

5
Listeria Control
  • Controlled traffic patterns (to prevent
    cross-contamination from raw product, public
    areas, outside)
  • GMPs (e.g., no raw or inedible product/trash
    in room)
  • Clean, dry, uncracked floors
  • Equipment/building design
  • Effective SSOPs

6
Sanitary Design Principles
  • Separate raw from RTE
  • physical, personnel traffic, air handling
  • Must be cleanable
  • equipment, walls, floors, ceilings, etc.
  • Made of compatible materials
  • inert, nonporous nonabsorbent
  • Need smooth accessible surfaces

7
  • Must be self-draining
  • no pooling, or dripping onto product zone areas
  • Framework must not be penetrated
  • bolts, studs, etc. must be welded to surface, no
    drilled or tapped holes
  • Proper ventilation
  • filtered, to prevent condensation, mold, etc.

8
Any small opening is hard to clean. Threaded
openings provide excellent harborage areas.
9
A previously stationary upper portion was hinged
to facilitate cleanup
10
Catch points allow water to puddle. Flat stock
also allows water to pool.
11
Cut outs eliminate water collection points.
12
Sanitary Zones
  • Zone 1 product contact surfaces
  • high priority for Listeria sampling
  • Zone 2 non-product contact areas, adjacent to
    product
  • ext. of equipment, chill units, etc.
  • Zone 3 More remote non- contact areas
  • phones, forklifts, walls, drains

13
Sanitary Zones (Contd)
  • Zone 4 remote areas, outside the processing
    room
  • bathroom doors, cafeteria, halls, etc.

14
Construction Site GMPs
  • Associated with gt30 recalls
  • Traffic pattern controls
  • Use of doors
  • Maintain negative pressure
  • Entry into sensitive area
  • Aerosol prevention
  • Temporary partitions

15
(No Transcript)
16
(No Transcript)
17
Four Step Cleaning
  • Dry clean-up
  • Rough rinse (90 of visible soil, 140-160ºF
    water)
  • Soap (proper concentration, type and
    application)
  • mechanical action important
  • Rinse, top down
  • before soap dries (prevent biofilm)

18
Listeria in Stainless Steel Scratch
19
Fat/Grease Film
  • Hanging water
  • greasy (white)
  • Caused by
  • water temperature lt130ºF
  • improper cleaner concentration
  • Alkaline detergent recommended

20
Cleaning
  • Control condensation
  • Focus on cleaning the room, not just the
    equipment
  • e.g., clean floor before equipment
  • Avoid contaminating clean equipment.

21
Use of Sanitizers for RTE
  • Apply by flood method
  • Use cold/tap water to sanitize
  • Double sanitize
  • rotate between 200 ppm chlorine and 25 ppm
    iodine
  • 200 ppm Quats. (residual effect)

22
Sanitizers
  • Floors 800 ppm quats
  • doorway foamers, rather than flood, for
    visual verification
  • Hands alcohol-based sprays, instead of dips.
  • Fog with 200 ppm quats weekly.
  • Verify concentration with test tape.

23
Foot Baths
Spray vs. foam
24
Heat as a Sanitizer
  • Flood equip. with 180ºF water.
  • Steam sanitize
  • 180ºF sprays on conveyors
  • Oven heating for peelers, slicers, etc.
  • 170ºF steam for 1 ¾ hrs.
  • 120ºF dry for 15 mins.

25

Drain Cleaning
  • Designated brushes
  • Designated sanitation employee do at end of
    their shift (leave room).
  • Use chlorinated alkaline cleaner.
  • Weekly clean all surfaces.
  • Sanitize with bucket of 75 ppm iodine.

26
Overhead Cleaning
  • Do monthly (min.)
  • All overheads
  • lights, conduit, pipes, etc.)
  • Use 4 step method
  • Use chlorinated alkaline cleaner
  • Clean ref. units using non- chlorinated alkaline
    cleaner
  • Sanitize by foaming 800 ppm quats (do not
    rinse).

27
RTE Cooler Cleanup
  • Clean from top down, using 4 step method (min.
    once a qtr.)
  • Use chlorinated alkaline cleaner on all, except
    ref. units
  • Clean racks thoroughly, watching for hidden
    areas (wheels, etc.)
  • Clean drains
  • Sanitize with 800 ppm quats

28
(No Transcript)
29
Conveyor Sanitizing System
30
Cross Traffic Ovens
  • Pick up heavy soil
  • Flood sanitize floors w/800 ppm quats
  • Squeegee away pools
  • Employees must change frocks, gloves, sleeves,
    and aprons before handling hot racks or
    (cooked) product.

31
RTE Employee Practices
  • Clean RTE clothing daily
  • Maintain sanitary lockers
  • Hairnets required by all.
  • Clean rubber footwear
  • street/tennis shoes a problem
  • Leave RTE garments in RTE area.
  • Stay within the designated traffic patterns.

32
Disposable Gloves
  • Hands must be clean before applying gloves
    inside glove is a great growth environment.
  • Change gloves as needed
  • holes
  • touching inedible items
  • Sanitize gloves often

33
Delayed Clean-Up
  • Cleaning and sanitizing occur less than once
    per day.
  • Must prove that this procedure is not causing
    contamination to product.

34
Additional Resources
  • OSU Thermal Processing for RTE Meat Products
    Presentations
  • www.ag.ohio-state.edu/meatsci/PresentationsTherm
    Proc06.html 
Write a Comment
User Comments (0)