Luminous Line Interachive UPS Systems

About This Presentation
Title:

Luminous Line Interachive UPS Systems

Description:

Luminous Inverter Delhi is company inverter dealer in Delhi-NCR, Gurgaon,Noida,Faridabad and Gaziabad along with inverter and car batteries at discounted price – PowerPoint PPT presentation

Number of Views:62

less

Transcript and Presenter's Notes

Title: Luminous Line Interachive UPS Systems


1
Tel 91-9716628483
Home
About Us Services Contact Us Luminous Line
Interactive UPS Systems Luminous has the widest
range of line interactive UPS systems. This
highly compact power packed UPS systems offer the
best and most reliable data security to small
desk tops or personal computers.
Luminous Invert er
Long Back up UPS
Sine Wave UPS
Higher KVA Inverter
Features Micro controller based intelligent
system No load shutdow n Pre-Alarm Audio Visual
Signals for Battery low Overload trip audio and
visual signals Battery Deep Discharge Protection
User-Friendly
Line Interactive UPS System
On-Line UPS
Luminous Bat t eries
Inverter Batteries
Car Batteries Specificat ions of UPS Line Int
eract ive
RATING 600 VA 750 VA 1000 VA RATING 600 VA 750 VA 1000 VA RATING 600 VA 750 VA 1000 VA
INPUT INPUT INPUT
Voltage Range 150V AC to 275V AC Voltage Range 150V AC to 275V AC Voltage Range 150V AC to 275V AC
Frequency 50Hz /- 6 Frequency 50Hz /- 6 Frequency 50Hz /- 6
OUTPUT OUTPUT OUTPUT
Pow er 600VA/360W 750VA/450W 1000VA/720W Pow er 600VA/360W 750VA/450W 1000VA/720W Pow er 600VA/360W 750VA/450W 1000VA/720W
Voltage(Inverter mode) 220V AC Nominal Voltage(Inverter mode) 220V AC Nominal Voltage(Inverter mode) 220V AC Nominal
Frequency(Inverter Mode) 50Hz /- 2 Frequency(Inverter Mode) 50Hz /- 2 Frequency(Inverter Mode) 50Hz /- 2
Voltage(Mains AVR Mode) 220V /- 12 Voltage(Mains AVR Mode) 220V /- 12 Voltage(Mains AVR Mode) 220V /- 12
Transfer T ime (Typical as) 3 m.s. Transfer T ime (Typical as) 3 m.s. Transfer T ime (Typical as) 3 m.s.
PROTECTION PROTECTION PROTECTION
Surge Protection Optional Provided Provided Surge Protection Optional Provided Provided Surge Protection Optional Provided Provided
Input Fuse Provided Input Fuse Provided Input Fuse Provided
Modem/Netw ork(OPT IONAL) RJ-11 RJ-45 RJ-45 Modem/Netw ork(OPT IONAL) RJ-11 RJ-45 RJ-45 Modem/Netw ork(OPT IONAL) RJ-11 RJ-45 RJ-45
BATTERY BATTERY BATTERY
Type Sealed Lead Acid Maintenance Free Type Sealed Lead Acid Maintenance Free Type Sealed Lead Acid Maintenance Free
Number 1 No. 12V 7Ah 2 No. 12V 7Ah 2 No. 12V 7Ah Number 1 No. 12V 7Ah 2 No. 12V 7Ah 2 No. 12V 7Ah Number 1 No. 12V 7Ah 2 No. 12V 7Ah 2 No. 12V 7Ah
Typical Recharge T ime 8 Hours (upto 90 of full capacity) Typical Recharge T ime 8 Hours (upto 90 of full capacity) Typical Recharge T ime 8 Hours (upto 90 of full capacity)
Protection Deep Discharge Protection Protection Deep Discharge Protection Protection Deep Discharge Protection
Deep Discharge Protection User Replaceable Deep Discharge Protection User Replaceable Deep Discharge Protection User Replaceable
PHYSICAL PHYSICAL PHYSICAL
Net Weight(kg.) approx. 7.0kg. 13.6 14.6 Net Weight(kg.) approx. 7.0kg. 13.6 14.6 Net Weight(kg.) approx. 7.0kg. 13.6 14.6
Gross Weight (kg) approx. 7.5kg. 14.4 15.6 Gross Weight (kg) approx. 7.5kg. 14.4 15.6 Gross Weight (kg) approx. 7.5kg. 14.4 15.6
Dimensions(W xHxD) mm 95x146x313 mm 120x196x385 120x196x385 Dimensions(W xHxD) mm 95x146x313 mm 120x196x385 120x196x385 Dimensions(W xHxD) mm 95x146x313 mm 120x196x385 120x196x385
LED INDICAT ION Inverter On,On Mains Normal, Mains On,Low Battery Trip. Inverter On, On Mains Normal, Mains On, Low Battery Trip.
COLOUR COLOUR COLOUR
Mains Normal Green Mains Normal Green Mains Normal Green
On Battery Mode Orange On Battery Mode Orange On Battery Mode Orange
Low Battery Pre-alarm Orange Blinking Low Battery Pre-alarm Orange Blinking Low Battery Pre-alarm Orange Blinking
Over Load/Batt. Low /Batt. Mode Red Short-Circuit Trip Over Load/Batt. Low /Batt. Mode Red Short-Circuit Trip Over Load/Batt. Low /Batt. Mode Red Short-Circuit Trip
No Load Shut Dow n Red Blinking No Load Shut Dow n Red Blinking No Load Shut Dow n Red Blinking
ALARMS ALARMS ALARMS
On Battery Mode Beeps Every 30Sec. On Battery Mode Beeps Every 30Sec. On Battery Mode Beeps Every 30Sec.
Low Battery Pre-alarm Continuous Beeping Low Battery Pre-alarm Continuous Beeping Low Battery Pre-alarm Continuous Beeping
Over Load/Batt. Low /Batt. Mode Inverter mode O/P trip w ith continuous beeping and low battery Short-Circuit Trip indication. Over Load/Batt. Low /Batt. Mode Inverter mode O/P trip w ith continuous beeping and low battery Short-Circuit Trip indication. Over Load/Batt. Low /Batt. Mode Inverter mode O/P trip w ith continuous beeping and low battery Short-Circuit Trip indication.
Low Battery Pre-alarm Continuous Beeping Low Battery Pre-alarm Continuous Beeping Low Battery Pre-alarm Continuous Beeping
COMPUT ER INT ERFACE Bi-directional (dry contact) Mains failure, DB9(OPT IONAL) COMPUT ER INT ERFACE Bi-directional (dry contact) Mains failure, DB9(OPT IONAL) COMPUT ER INT ERFACE Bi-directional (dry contact) Mains failure, DB9(OPT IONAL)
Low Battery pre-alarm UPS computer shutdow n Low Battery pre-alarm UPS computer shutdow n Low Battery pre-alarm UPS computer shutdow n
ENVIRONMENTAL ENVIRONMENTAL ENVIRONMENTAL
Operating Temperature 0-40 deg C (32-104 deg F) Operating Temperature 0-40 deg C (32-104 deg F) Operating Temperature 0-40 deg C (32-104 deg F)
Storage Temperature 0-40 deg C (32-104 deg F) Storage Temperature 0-40 deg C (32-104 deg F) Storage Temperature 0-40 deg C (32-104 deg F)
Humidity 0-95 RH non-condensing Humidity 0-95 RH non-condensing Humidity 0-95 RH non-condensing
Feed Back Sitemap Disclaimer XML Sitemap
RSS Feeds ROR Sitemap Blog A rticle Link
Exchange
2
Powered by- A ppextech
Write a Comment
User Comments (0)