HE UTTAR PRADESH FIRE PREVENTION AND FIRE SAFETY RULES 2005

Description:

MAINTAINANCE OF FIRE FIGHTING SYSTEM The Fire protection system should be regularly maintained by competent agency so that they are operative in case of emergency. – PowerPoint PPT presentation

Number of Views:558
Avg rating:3.0/5.0
Slides: 20
Provided by: AmitabhSh
Category:

less

Write a Comment
User Comments (0)
Transcript and Presenter's Notes

Title: HE UTTAR PRADESH FIRE PREVENTION AND FIRE SAFETY RULES 2005


1
HE UTTAR PRADESH FIRE PREVENTION AND FIRE SAFETY
RULES 2005
  • MINIMUM STANDARDS

2
MEANS OF ACCESS
  • Width of street on which building abuts
  • shall be min 12 M
  • The road shall not terminate on dead end.
  • Open space around building should not be
  • used for parking.
  • Main passage should not be less than 4.5M
  • and gate arch not less than 5M height.

3
UNDERGROUND / OVER GROUND STATIC TANKS
  • Water replenishment min 1000 lpm.
  • In case of tank in pathway. Covering slab
  • should withstand min 22.5 ton vehicular
  • load.
  • Water tank should feed the domestic water
  • tank by overflow.
  • FB inlet 4/2 way at street level connected
  • with static tank. 150 mm pipe.

4
AUTOMATIC SPRINKLER SYSTEM
  • BASEMENT CAR PARK IF AREA
  • EXCEED 200 SQ M
  • ANY ROOM / COMPARTMENT
  • EXCEEDING 1125 SQ M
  • DEPARTMENT STORE EXCEEDING
  • 750 SQ M
  • ALL FLOORS BUILDING OVER 30M

5
FIRST AID HOSE REELS
  • Should be provided with 30 M long hose
  • pipe on every floor.
  • Min dia of hose should be 19mm.
  • Connected with riser / down comer.

6
FIRE EXTINGUISHER
  • A-Fires in Ordinary combustibles (Wood, Vegetable
  • fibres, rubber, plastics, Paper and the likes).
    Gas expelled
  • Water and Antifreeze type extinguishers and Water
  • Buckets.
  • B-Fires in flammable liquids, paints, grease,
    solvents and
  • the likes. Chemical Extinguishers of Carbon
    dioxide type
  • and Dry Powder type and Sand Buckets.
  • C-Fires in Gaseous substances under pressure and
  • liquefied gases. Chemical Extinguishers of Carbon
    di
  • oxide and Dry Powder type.
  • D-Fires in reactive chemicals, Active metals and
    the
  • likes. Special type of Dry Powder, Extinguishers
    and sand
  • buckets

7
FIRE EXTINGUISHER
  • One 9-litre water/sand bucket shall be provided
    for every 100 sq. m of the floor area or part
    thereof and one 9-litre water type extinguisher
    shall be provided to six buckets or part thereof
    with a minimum of one extinguisher and two
    buckets per compartment of the building.
  • Acceptable replacement WATER BUCKETS Water type
    Extinguishers For each 9 litre Extinguisher For
    one bucket For two buckets Dry Sand1 bucket 3
    bucket ---Carbon-di-Oxide Extinguishers(IS
    2878)03 Kg.09 Kg09 KgDry Powder Extinguisher(IS
    2171)02 Kg 05 Kg 05 Kg(In one or
    more extinguishers)
  • For rooms containing electrical transformers,
    switchgears, motors and/or electrical apparatus
    only, not less than two 2 Kg dry powder or carbon
    dioxide type of extinguishers shall be provided
    within 15 m of the apparatus.
  • Where motors and/or other electrical equipments
    are installed in rooms other than those
    containing such equipments only, one 5 Kg dry
    powder or carbon di oxide extinguisher shall be
    installed within 15 m of such equipments in
    addition to the requirement of rules 4.1.3.2 and
    4.1.3.4 for this purpose, the same extinguisher
    may be deemed to afford protection to all
    apparatus within 15 m thereof.
  • Where electrical motors are installed on
    platforms, one 2 Kg dry powder or carbon di oxide
    extinguisher shall be provided on or below each
    platform.

8
COMPARTMENTATION
  • ALL FLOORS SHALL BE
  • COMPARTMENTED WITH AREA NOT
  • EXCEEDING 750 SQ M BY A
  • SEPERATION WALL WITH 2 H FIRE
  • RATING

9
Automatic Fire Detection system / Manually
operated alarm System
  • Automatic Fire Detection system /
  • Manually operated alarm systems is to be
  • provided in all the buildings as per the
  • provisions laid in NBC.

10
PUBLIC ADDRESS SYSTEM
  • In large and hi rise building PA system
  • linked with the automatic fire alarm system
  • should be provided.

11
ILLUMINATED EXIT WAY MARKING SIGNS
  • All the exits should be clearly marked.
  • Illuminated signage should be fixed at all
  • exit routes and points to assist in effective
  • evacuation of people in case of emergency.

12
ALTERNATE SOURCE OF ELECTRIC SUPPLY
  • All hi rise buildings should have provision
  • of alternative source of power supply for
  • emergency lights and pumps.

13
WET RISER / DOWN COMER
  • Wet Riser / Down comer to be provided as
  • per the provision laid in NBC.

14
SET BACK
  • All buildings should have necessary set
  • back clear of all construction as per NBC.

15
FIRE DRILL
  • All high rise buildings should practice Fire
  • Drill for fast and effective evacuation in
  • case of emergency.

16
MAINTAINANCE OF FIRE FIGHTING SYSTEM
  • The Fire protection system should be
  • regularly maintained by competent agency
  • so that they are operative in case of
  • emergency.

17
STAFF TRAINING FOR OPERATION OF FIRE
FIGHTING SYSTEM
  • All high rise should have trained staff to
  • operate the fire protection system.

18
EVACUATION PLAN AND DRILL

19
PERIODICAL FIRE SAFETY AUDITS
  • PERIODIC RENEWAL OF FIRE
  • CLEARANCE AFTER
  • DEPOSITING PRESCRIBED FEES
  • To be done as per requirement of Fire
  • Department