Title: Installation and Setting Up of GLOSS OTT Radar Tide Gauges with DCP Telemetry for ODINAFRICA and Future Developments
1Installation and Setting Up of GLOSS OTT Radar
Tide Gauges with DCP Telemetry for ODINAFRICAand
Future Developments
- Peter Foden and Jeff Pugh
- UNESCO/IOC Oostende 2006
2ODINAFRICA - Ocean Data and Information for
Africa Current, In Progress and Proposed GLOSS
Tide Gauges
3OTT Tide Gauge Kit of Parts
4Main Sea Level Sensors Radar and Pressure
5ODINAFRICA - Meteosat DCP Tide Gauge
6- The Component Parts of the OTT Gauge
7OTT Logosens2 Data Logger
8OTT DCP/HDR Transmitter - Connections
9OTT Power Supply PCU 12
10Kalesto Radar Sensor Connections
11Pressure Sensor - Cable Connections
12Radar Sensor Support Arm Designs
13Simplified Radar Support Arm Design
14Pressure Sensor mounting support bracket example
- Needed to keep the Sensors in a stable and
repeatable datum positions
15- The Proposed Tide Gauge Sites
16Proposed OTT TG site Karachi, Pakistan
17Proposed TG site Nouakchott, Mauritania
18Tide Gauge Hut, Takoradi,Ghana Proposed
sitefor OTT Radar Gauge
19Proposed OTT TG site Port Sonara, Limbe,
Cameroon
20Proposed new OTT TG Site Pointe Noire, Congo
21Summary of TG Site requirements
- A weather proof tide gauge hut for electronics
- 24 hour security
- Electricity and if possible Telephone
- Tools for installation (I have a list)
- A mounting arm for the radar gauge
- Mountings for the pressure sensors (one below low
tide and one at approximately MSL) - A pole for antennas
- A simple stilling well for calibration checks
- Regular Dipper and Tide Staff Measurements
22Staff Gauges and Dippers Regular Checks
Available in 1 metre lengths that can be
joined Plastic or metal, graduated in centimetres
Dipper gives audio and visual indication of
height from a reference point to Sea Level
23- Antenna Alignment and Data Checking
24Antenna Pointing Utility Eumetsat Website
25DCP Data Checking and Download Eumetsat Webpage
26ODINAFRICA Telemetry issues
- Meteosat DCP is low cost and conforms to
standards of Pacific TWS. Automatic data flow to
GTS. - Limited bandwidth, cannot report faster than
every 15 minutes. The new minimum recommended
data reporting rate is every 6 minutes. - Alternative to DCP is required for
- tsunami monitoring and faster data delivery
BGAN Broadband and SMS
27BGAN Terminals
True Global Wi-Fi Data rate up to 492 kb/s Data
messages by SMS or Internet
28(No Transcript)
29Liverpool BGAN Tide Gauge
30BGAN Pricing Standard Economy Rate
- BGAN Terminal 2800
- Activation charge 35
- Monthly subscription 49
- IP Data rate/Mb 8.23
- Static IP/Month 30
- SMS per Message 0.57
- 5 Mb/Month of data 120.15
31Summary
- For the first time high speed, low-cost real-time
data telemetry from remote areas is possible
using BGAN, addressing the poor latency issues of
earlier telemetry systems - Number of technical issues for BGAN
- Long term reliability, Up time, Latency of SMS
messages and interfacing to the GTS - Adoption of broadband will have implications for
IT infrastructures. In particular the high
volume of data produced, how to store it and keep
it secure
32(No Transcript)
33Possible Tsunami Monitoring System using
BGANData Telemetry and SMS
34ODINAFRICA Ocean Data and Information for Africa
35New development - BGAN
- True global Wi-Fi
- Data rate of up to 492 kb/s
- Suitable for Tsunami monitoring
- Portable and will work outside UK